Specifications
Brand Name :
Citest
Model Number :
DKE-803/102/101/114/402
Certification :
CE
Place of Origin :
-
MOQ :
N/A
Price :
negotiation
Supply Ability :
10 M tests/month
Delivery Time :
2-4 Weeks
Packaging Details :
10T/25T/40T/50T
Product :
Keta/mine KET Drug Abuse Test Kit Diagnosis Fast Reading With Certificate CE
Cat. No. :
DKE-803/102/101/114/402
Principle :
Chromatographic Immunoassay
Format :
Dipstick, Cassette, Panel, Device, Cup
Specimen :
Urine,Oral Fluid,Powder,WB/S/P,Hair
Certificate :
CE
Reading Time :
5 minutes
Pack :
10T/25T/40T/50T
Storage Temperature :
2-30℃
Sensitivity :
97.5%
Specificity :
98.2%
Accuracy :
98.0%
Cut-Off :
50 ng/mL* ,100 ng/mL, 200 ng/mL, 300 ng/mL, 500 ng/mL, 1000 ng/mL*,0.2 ng/mg
Description

Ketam/ine KET Drug Abuse Test Kit Diagnosis Fast Reading With Certificate CE

Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Device, Cup
Specimen Urine,Oral Fluid,Powder,WB/S/P,Hair
Certificate CE
Reading Time 5 minutes
Pack 10T/25T/40T/50T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 97.50%
Specificity 98.20%
Accuracy 98.00%
Cut-Off 50 ng/mL* ,100 ng/mL, 200 ng/mL, 300 ng/mL, 500 ng/mL, 1000 ng/mL*,0.2 ng/mg

High Sensitivity Oral Fluid Keta/mine(KET) Convenient Accurate Drug Abuse Diagnosis Fast Reading Test Kits With CE

Application And Description:

Keta/mine is a dissociative anesthetic developed in 1963 to replace PCP (Phenc/yclidine). While Keta/mine is still used in human anesthesia and veterinary medicine, it is becoming increasingly abused as a street drug. Keta/mine is molecularly similar to PCP and thus creates similar effects including numbness, loss of coordination, sense of invulnerability, muscle rigidity, aggressive / violent behavior, slurred or blocked speech, exaggerated sense of strength, and a blank stare.
There is depression of respiratory function but not of the central nervous system, and cardiovascular function is maintained. Keta/mine's duration of action in a clinical setting is 30 min to 2 h intramuscularly and 4–6 h orally.

How to use?

Allow the test cassette, specimen, and/or controls to reach room temperature (15-30ºC) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.

1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.

2. Remove the collector from the sealed pouch and insert the sponge end of the collector into the mouth. Actively swab the inside of the mouth and tongue to collect oral fluid for a total of 3 minutes until the sponge becomes fully saturated. Gentle pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated.

3. Remove the collector from the mouth. Place saturated oral fluid collector into chamber and press sponge fully against the strainer to collect oral fluid. Discard the collector. Snap the cap shut on the collection tube.

4. Place the test cassette on a clean and level surface. Unscrew cap cover from the collection tube. Invert the collection tube and transfer 3 drops of oral fluid (approximately 120 µL) into specimen well of the test cassette and start the timer. Avoid trapping air bubbles in the specimen well. Place screw cap on the collection tube. See illustration below.

5. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not read results after 1 hour.

6. Apply the security seal over screw cap and send to the laboratory for confirmation if necessary.

98.0% Accuracy Keta/mine KET Drug Abuse Test Kit Diagnosis Fast Reading

DIRECTIONS FOR DEVICE USE


Allow the test device, specimen, and/or controls to reach room temperature (15-30ºC) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.


1. Remove the test device from the sealed pouch and use it within one hour.


2. Take off the device cap and insert the absorbent wick to the mouth, put it under the tongue to collect oral fluid until the control line appears.


3. Put the device cap back outside of the absorbent wick and lace the test device on a clean and level surface. See illustration below.


4. Read results at 10 minutes. Do not read results after 15 minutes.

98.0% Accuracy Keta/mine KET Drug Abuse Test Kit Diagnosis Fast Reading

INTERPRETATION OF RESULTS


(Please refer to the illustration above)


NEGATIVE:* Two lines appear. One colored line should be in the control line region (C), and another apparent colored line should be in the test line region (T). A negative result indicates that the Synthetic Marijuana metabolite concentration is below the detectable level (25ng/mL).


*NOTE: The shade of color in the test line region (T) may vary, but it should be considered negative whenever there is even a faint colored line.


POSITIVE: One colored line appears in the control line region (C). No line appears in the test line region (T). A positive result indicates that the Keta/mine(KET) concentration exceeds the detectable level (50 ng/mL).


INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test. If the problem persists, discontinue using the lot immediately and contact your local distributor.

ORDER INFORMATION

Cat. No. Product Specimen Pack
DKE-102 Keta/mine (KET)Rapid Test Cassette Urine 40T
DKE-114 Ket/amine (KET)Rapid Test Panel Urine 40 T
DKE-101 Keta/mine (KET)Rapid Test Dipstick Urine 50 T
DKE-802 Keta/mine(KET) Rapid Test Cassette Oral Fluid 25 T
DKE-803 Keta/mine(KET) Rapid Test Device Oral Fluid 25 T
DKE-402 Keta/mine(KET) Rapid Test Cassette WB/S/P 40 T
DKE-X14 Keta/mine (KET)Rapid Test Panel Powder 25 T
DKE-H902 Keta/mine (KET)Rapid Test Cassette Hair 10 T
Send your message to this supplier
Send Now

98.0% Accuracy Keta/mine KET Drug Abuse Test Kit Diagnosis Fast Reading

Ask Latest Price
Brand Name :
Citest
Model Number :
DKE-803/102/101/114/402
Certification :
CE
Place of Origin :
-
MOQ :
N/A
Price :
negotiation
Contact Supplier
98.0% Accuracy Keta/mine KET Drug Abuse Test Kit Diagnosis Fast Reading
98.0% Accuracy Keta/mine KET Drug Abuse Test Kit Diagnosis Fast Reading
98.0% Accuracy Keta/mine KET Drug Abuse Test Kit Diagnosis Fast Reading

CITEST DIAGNOSTICS INC.

Verified Supplier
3 Years
zhejiang, hangzhou
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
80000000-100000000
Employee Number :
500~10000
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement