Cross contamination control through negative pressure environment option.
GMP modular design with minimized joints and seams.
Technical Specifications & Parameters:
Material | SUS 304/316L stainless steel | ||||
Filter Module | Pre-filter, comport filter, HEPA filter | ||||
Core Part | Air Blower | ||||
Model No. | LWR 13-120060 | LWR 34-150120 | LWR 75-200200 | LWR 112-300200 | LWR 186-400250 |
Outer Size | 1300×1200×2570 | 1600×1800×2570 | 2100×2800×2570 | 3100×2800×2570 | 4100×3300×2570 |
Inner Size | 1200×600×2000 | 1500×1200×2000 | 2000×2000×2000 | 3000×2000×2000 | 4000×2500×2000 |
Rated Air Velocity | 0.45±20% | ||||
Cleanliness Class | Same as the background area | ||||
Power Supply | 380V, 50Hz | ||||
Power (kW) | 0.8 | 2 | 4 | 4 | 7.5 |
Note: The specifications listed in above table are only for customer’s reference. It is mostly designed and manufactured according to customer’s URS.
Containment System:
Main Stream - The opening provides an airflow velocity of 0.45 m/s.
HEPA fan module provides laminar flow of particlefree air (measured at 0.3µm particles) to meet clean room requirements—99.995% efficient ULPA filters also available.
Filter Module
—— Pre filter -- Panel filter G4
—— Comfort filter -- Bag filter F8
—— HEPA filter -- Gel sealed mini-pleated HEPA filter H14
380 V power supply
Product Outline Design: