Specifications
Brand Name :
LENGE
Model Number :
LENGE-PVDF
Certification :
CE/SGS/ISO/FDA
Place of Origin :
China
MOQ :
1 PCS
Price :
USD 20-30 / PCS
Payment Terms :
T/T, L/C
Supply Ability :
2000 Pieces Per Month
Delivery Time :
5 - 7 Days
Packaging Details :
Cartons
Filter material :
Hydrophilic polyvinylidene difluoride (PVDF)
Gasket Material :
226 Silicon Rubber
Supports/Diversion :
PP
Length :
20 Inch
Pore size :
0.22 / 0.45μm
Application :
Chemical Industry , Electronics Industry , Pharmaceutical Industry
Description

20 Inch 0.45um PVDF Pleated Filter Element With 226 Silicon Rubber

PVDF Pleated Filter Cartridge is made of hydrophilic polyvinylidene difluoride (PVDF) filter membrane and polypropylene material parts by advanced hot-melt sealing technology in a controlled Class-100 clean environment without any adhesive and surfactant, and meets the technical requirements of the national standard of the People's Republic of China GB/T 34244-2017 filter cartridge for liquid sterilization.

Material of filter element components:
Filter material : Hydrophilic polyvinylidene difluoride (PVDF)

Supports/Diversion : PP

Core/Cover/End cover/End caps : PP

Sealed leads/Fins : PP,Built in stainless steel

O-Ring : 222,226 silicon rubber, washer with double split etc.

Sealing technology : Thermal bonding without adhesives

Characteristics and features:

- Excellent high-temp resistance and extensive chemical compatibility.

- Low protein adsorption performance, suitable for filtration of culture solution, biological reagent and aseptic vaccine.

- The samples of filter cartridges successfully passed the bacterial retention testing required by regulations, LRV>7. Integrity can be maintained after repeated disinfection.

- Each filter cartridge should pass the integrity test before leaving the factory. The limitations of integrity testing were correlated with the results of bacterial retention testing.

- All the compositions meet the requirements of the biological testing characteristics of USP Class 6 plastic products at 121°C and the food contact materials listed in the relevant regulations of Chapter 21 of the Federal Regulations of the United States (CFR).

- It is manufactured under ISO 9001 and ISO 14001 systems and Class 100 clean environment.

- Production and usage are traceable.

Technical specifications and operating parameters:

Size

Diameter: 2.75"(69 mm)

Length: 2.5"/5"/10"/20"/30"/ 40" etc.

Removal Ratings (µm) 0.22, 0.45
Filtration area Single 10" filter element is about 0.65m²
Maximum Differential Pressure 0.4MPa/21℃, 0.24MPa/80℃
Maximum Operating Temperature 80℃
Steam Sterilization 121℃/30min.

Typical application:
- Filtration of blood products
- Filtration of biological reagent
- Filtration of culture medium
- Filtration of vaccines
- Sterilization filtration of antibiotic solution

Adapter Style:

0.45um PVDF Pleated Filter Element 20 Inch With 226 Silicon Rubber

Ordering information:

1 2 3 4 5 6 7
PVDF 0.22 --- 10 A S P --X

1 Membrane Hydrophilic polyvinylidene difluoride (PVDF)
2 Pore size 0.22 / 0.45μm
3 Length 2.5" / 5” / 10” / 20” / 30” / 40”
4

Connector/End Cover

A/AA/B/BB/C/CC/D/E/EE/F

Spear+222

Spear+222adapter with encapsulated reinforcing stainless steel ring

Flat+222

Flat+222adapter with encapsulated reinforcing stainless steel ring

Spear+226

Spear+226adapter with encapsulated reinforcing stainless steel ring

Flat+Flat

Flat+226

Flat+226adapter with encapsulated reinforcing stainless steel ring

Flat+215

Spear+3 Flange Bayonet adapter

5

Gasket Material

S, E, F, FF

S: Silicon rubber

E: EPDM rubber

F: Fluorine rubber

FF: Encapsulated fluoroelastomer

6 Application Pharmaceutical grade for bio-pharmaceutical&food and beverage industry
7 Special Specification Remarks Standard Specification Default

Production equipment - Introduction of automatic production line

0.45um PVDF Pleated Filter Element 20 Inch With 226 Silicon Rubber

0.45um PVDF Pleated Filter Element 20 Inch With 226 Silicon Rubber

  1. International advanced production lines
  2. From the storage, production and processing of raw materials to inspection and detection are all carried out in the 100-grade purification workshop.
  3. The material of components are FDA approved, which meets the requirements of new USP for biological safety test of VI-121℃ plastics in VIVO
  4. Each filter cartridge has passed the integrity test and can be traced throughout the whole process.
Send your message to this supplier
Send Now

0.45um PVDF Pleated Filter Element 20 Inch With 226 Silicon Rubber

Ask Latest Price
Watch Video
Brand Name :
LENGE
Model Number :
LENGE-PVDF
Certification :
CE/SGS/ISO/FDA
Place of Origin :
China
MOQ :
1 PCS
Price :
USD 20-30 / PCS
Contact Supplier
video
0.45um PVDF Pleated Filter Element 20 Inch With 226 Silicon Rubber
0.45um PVDF Pleated Filter Element 20 Inch With 226 Silicon Rubber
0.45um PVDF Pleated Filter Element 20 Inch With 226 Silicon Rubber

Wuxi Lenge Purification Equipments Co., Ltd.

Site Member
3 Years
jiangsu, wuxi
Since 1998
Business Type :
Manufacturer
Total Annual :
45000000-50000000
Employee Number :
350~400
Certification Level :
Site Member
Contact Supplier
Submit Requirement