Class 100 SS304 Laminar Flow Hood for GMP Modular Clean Room Area with PVC Softwall
Brief introduction
1, Class 100 Laminar Flow Hood is a kind of air cleaning unit that can offer some high clean environment , can install above needing the craft of high cleanliness to click in a flexible way , clean laminar flow is covered and can be used individually, a lot of all right associations become the clean area of banding.
2, Class 100 Laminar Flow Hood after high-efficient filter, is it shed layer to form with certain wind speed air, make clean air current vertical to flow while being one-way , guarantee workspace reach the cleanliness of the technological requirement, send into the workspace.
3, There are two kinds installing of outer and inside of air blowers, installation way is hanging type and floor support type two kinds.
Cleanliness in the workspace≥0.5m grain of dus≤3.5(FS209E100 grade )
the noise of liter≤64 Db(A)
Average air velocity0.3-0.55m/s
Except that have specification production now according to our factory, can especially design and make according to customer's enquiry .
It is a kind of air purification equipment that can offer some high clean environment that laminar flow is covered. It is made up by case body , air blower , result air cleaner , damping layer , lamps and lanterns of the beginning ,etc. mainly, the outer cover is gushed out and molded. This product can both hang and be supported on the ground, the structure is compact, easy to use. Can use individually, can a lot of connections make up and lead the strong clean area.
Class 100 Laminar Flow Hood is after passing the air with certain wind pressure by the air blower on the high-efficient air cleaner , pressed by the damping layer, it is the clean air that presents the vertical laminar flow type air current to send into the workspace, thus guaranteed the workspace reaches the high cleanliness that the craft needs. Compared with toilet Clean laminar flow covering, have investment provinces, with instant effect, requiring the building construction of factory building low, install it conveniently, such advantages as the province electricity ,etc., used in such
1.Specification: HEPA supply outlet is made of fine cold-rolled steel plate with the surface of electrostatic spray. The ingredient of HEPA supply outlet include plenum chamber, HEPA, diffusion perforation panel. With the advantages of small investment and simple construction, HEPA supply outlets are usually installed at the ceiling of clean room as the terminal air purification device.
2.Features:
a. The valve of HEPA supply outlet is used to adjust uniform air blow and static pressure by the integrated of HEPA and plenum box.
b. Light weight and easy installation make it especially suitable for the clean room
of choi steel partition.
Size (L x W x H) | 1035 x 730 x 600 mm 1) | 1340 x 730 x 600 mm | 1340 x 2090 x 600 mm |
Hepa Size | 915 x 610 x 69 mm-1 PCS | 1220 x 610 x 69 mm-1 PCS | 1220 x 610 x 69 mm-3 PCS |
Effiency | G4(EN779) | G4(EN779) | G4(EN779) |
H14(EN1822) | H14(EN1822) | H14(EN1822) | |
Operating Power | 180W | 240W | 680W |
Avg Air Velocity | 0.36m/s~0.54m/s | ||
Touch Sreen | Siemens | ||
PLC | Siemens | ||
PAO test port | Φ8MM | ||
Differential Manometer | DWYER | ||
Curtain | PC /PVC | ||
Air Velocity | 0-1 m/s | ||
Lighting | ≥300 Lux | ||
Weight | 69 kg | 84 kg | 178 kg |