Specifications
Brand Name :
ASLI
Model Number :
UV-290
Certification :
CE , ISO, SGS
Place of Origin :
China
MOQ :
1 set
Price :
negotiate
Payment Terms :
T/T, Western Union
Supply Ability :
100 sets per month
Delivery Time :
25workdays
Packaging Details :
standard export plywood case
Internal Dimension :
W1150xH500xD500mm
External Dimension :
W1400xH1600xD750mm
Volume :
290 Liters
Applicable Standard :
GB/T16422,GB/T5170.9
Application :
Plastic
Humidity Range :
more than 95%R.H.
Description

high UV radiation and humidity UV Degradation chamber/Rack for aging laboratory


UV Aging Test Chambe for PV Module purpose
To precondition the module with ultra-violet (UV) radiation before the thermal cycle/humidity freeze tests to identify those materials and adhesive bonds that are susceptible to UV degradation


UV Aging Test chamber for pv module apparatus
1.A temperature -controlled test chamber with a window or fixtures for a UV light source and the module under test. The chamber shall be capable of maintaining the module temperature at 60±5ºC

2.A means for monitoring the temperature of the module to an accuracy of ±2.0ºC and repeatability of ±0.5ºC. the temperature sensors shall be attached to the front or back surface of the module near the middle without obstructing any of the UV light incident on the active cells within the module. If more than one module is tested simultaneously, it will suffice to monitor the temperature of one representative sample

3.Instrumentation capable of measuring the irradiance of the UV light produced by the UV light source at the test plane of the module, within the wavelength ranges of 280nm to 320nm and 320nm to 400nm with an unceratinly of ±15% or better

4.A UV light source capable of producing UV radiation with an irradiance uniformity of ±15% over the test plane of the module with no appreciable irradiance at wavelengths below 280nm and capable of providing the necessary total irradiance in the different spectral regions of interest


5.For light sources with a negligible spectral content in the visible range the module shall be short circuited. Alternatively the module can be connected to a load sized such that the module will operate near the maximum power point . the latter is recommended for light sources emitting a significant portion of light in the visible spectrum where the module exhibits a power equal to or large than20% of its STC measured power

UV aging test chamber procudrue

1.Using the calibrated radiometer measure the irradiance at proposed module test plane and ensure that at wavelengths between 280nm and 400nm it does not exceed 250w/m2 (i.e. about five times the natural sunlight level) and that it has a uniformity of ±15% over the test plane

2.Short-cicuit or attach the resistive load to the module and mount it in the test plane at the location selected in a 1), normal to the UV irradiance beam , make sure that the module temperature sensors read 60±5ºC

3.Subject the module front side to a total UV irradiation of at least 15KW/m2 in the wavelength range between 280nm and 400nm with at least 3% , but not more than 10% in the wavelength and between 280nm and 320nm ,while maintaining the module temperature within the prescribed range

high UV radiation and humidity UV Degradation chamber/Rack for aging laboratory​ Technical Parameters

Model

UV-290

Internal Dimension WxHxD (mm)

1150x500x500

External Dimension WxHxD (mm)

1400x1600x750

Applicable Standard

GB/T16422,GB/T5170.9

Temperature Range

R.T.+15°C~+70°C

Temperature Fluctuation

±0.5°C

Humidity Range

≥95%R.H.

Environmental Temperature for Use

+5°C~+35°C

Test Light Source

UVA,UVB UV light

Wave Length of Test light Source (nm)

280~400

Center Distance between Sample and Tube (mm)

50±2

Center Distance Between Tubes (mm)

75±2

Material of Internal Case

Stainless steel with sanding polish

Material of External Case

Stainless steel with sanding polish or painting coated

Heating and Humidifier

Electric-heat type steam generator ,heating and humidification

Safety System

Operation Interface

Digital smarts touch key input (Programmable)

Running Mode

Program/constant running type

Input

Black panel thermometer.PT-100 Sensor

Standard Configuration

1 pc Stainless steel shelves

Safety Configuration

Protection of electric leakage, power outage when over-load, over-temperature protection, water short storage, ground lead protection

Power

AC220V 1 phase 3 lines, 50HZ

High UV Radiation And Humidity UV Aging Test Chamber / Rack For Aging Laboratory High UV Radiation And Humidity UV Aging Test Chamber / Rack For Aging Laboratory

High UV Radiation And Humidity UV Aging Test Chamber / Rack For Aging Laboratory
Product Description

uv irradiation chambers can simulate the sun, rain and dew to damage the material,the machine using UV lamp simulate the effect of sunlight, cold rain and dew. Being tested materials are placed in a certain environment which the light and moisture are alternating. The materials are tested for several days or weeks, you can know the damage of material at outside for several months or several years, Damage types include: bleaching, discoloration, loss of light, powder, crack, turbidity, bubble-based, embrittlement, strength decline and oxidation.


Corresponding standard:


Accord with ASTMG53-77, GB,GJB,MIL,ASTM,CNS,IEC,JIS,AATCC,DIN,Fed Test,BS,SAE

Applicable industries:


accelerated weather tests is widely used in paint, resins, plastics, printing and packaging,aluminum, adhesives, auto, cosmetics, metals, electronics, electroplating, medicine, etc.

Product Pictures

High UV Radiation And Humidity UV Aging Test Chamber / Rack For Aging Laboratory

High UV Radiation And Humidity UV Aging Test Chamber / Rack For Aging Laboratory

High UV Radiation And Humidity UV Aging Test Chamber / Rack For Aging Laboratory

High UV Radiation And Humidity UV Aging Test Chamber / Rack For Aging Laboratory

Acceleration Stability Chamber with UV and Photostability Requirement for Plastic

Send your message to this supplier
Send Now

High UV Radiation And Humidity UV Aging Test Chamber / Rack For Aging Laboratory

Ask Latest Price
Brand Name :
ASLI
Model Number :
UV-290
Certification :
CE , ISO, SGS
Place of Origin :
China
MOQ :
1 set
Price :
negotiate
Contact Supplier
High UV Radiation And Humidity UV Aging Test Chamber / Rack For Aging Laboratory
High UV Radiation And Humidity UV Aging Test Chamber / Rack For Aging Laboratory
High UV Radiation And Humidity UV Aging Test Chamber / Rack For Aging Laboratory
High UV Radiation And Humidity UV Aging Test Chamber / Rack For Aging Laboratory

ASLi (CHINA) TEST EQUIPMENT CO., LTD

Active Member
10 Years
Since 1988
Business Type :
Manufacturer
Total Annual :
10000000-12000000
Employee Number :
100~120
Certification Level :
Active Member
Contact Supplier
Submit Requirement