Model | TH-80(A~F) | TH-150(A~F) | TH-225(A~F) | TH-408(A~F) | TH-800(A~F) | TH-1000(A~F) |
Internal Dimension WxHxD (mm) | 400x500x400 | 500x600x500 | 600x750x500 | 600x850x800 | 1000x1000x800 | 1000x1000x1000 |
Enternal Dimension WxHxD (mm) | 950x1650 x950 | 1050x1750 x1050 | 1200x1900 x1150 | 1200x1950 x1350 | 1600x2000 x1450 | 1600x2100 x1450 |
Temperature Range | Low Temperature(A:25ºC B:0ºC C:-20ºC D:-40ºC E:-60ºC F:-70ºC) High Temperature 150ºC | |||||
Humidity Range | 20%~98%R.H.(10%-98% R.H. / 5%-98% R.H ,is a special optional condition, need Dehumidifier) | |||||
Analytic Accuracy/ Distribution uniformity of temperature and humidity | 0.1ºC; 0.1% R.H/±2.0ºC; ±3.0% R.H. | |||||
Control Accuracy of Temperature and Humidity | ±0.5ºC; ±2.5% R.H. |
Model | TS-49(A~C) | TS-80(A~C) | TS-150(A~C) | TS-252(A~C) | TS-450(A~C) | ||||
Internal Dimension WxHxD ( mm) | 400x350x350 | 500x400x400 | 600x500x500 | 700x600x600 | 800x750x750 | ||||
External Dimension WxHxD (mm) | 1400x1800x1400 | 1550x1950x1550 | 1600x2000x1700 | 1700x2100x1750 | 1800x2200x1900 | ||||
Temperature Range: Type A:-40ºC~+150ºC: Type B:-55ºC ~+150ºC :T ype C:-65ºC ~+150ºC ( 200ºC is Optional) | |||||||||
temperature Range of Testing zone | High: +60ºC~+150ºC ( 200ºC is Optional); Low: -10ºC~-40ºC / -55ºC / -65ºC | ||||||||
Exposure Time of High Temperature | +60ºC ~ +150ºC (200ºC is Optional) 30Mins |
Model | THR-volume (low-temperature options : A ~ F) |
Inner Dimensions(cm) | Customers designated space size and design |
Temperature Range | Low Temperature(A:25ºC B:0ºC C:-20ºC D:-40ºC E:-60ºC F:-70ºC) High Temperature 80ºC (80ºC ~150ºC is optional) |
Humidity Range | 20%~98%R.H.(10%-98% R.H. / 5%-98% R.H ,is a special optional condition, need dehumidifier) |
Analytic Accuracy/Distribution Uniformity of Temperature& Humidity | 0.1ºC; 0.1% R.H/±2.5ºC; ±3.5% R.H. |
Control Accuracy of Temperature and Humidity | ±0.5ºC; ±2.5% R.H. |
Model | SH-60 | SH-90 | SH-120 | SH-160 | SH-200 | ||||
Internal Dimension WxHxD (mm) | 600x450x400 | 900x600x500 | 1200x800x500 | 1600x800x500 | 2000x1000x500 | ||||
External Dimension WxHxD (mm) | 1100x600x1200 | 1400x950x1200 | 1900x1300x1400 | 2300x1300x1400 | 2700x1500x1500 | ||||
Lab Temperature | Saline test (NSS ACSS) 35±1 °C ;Corrosion Test (CASS)50±1 °C | ||||||||
Pressure Bucket Temperature | Saline test method (NSS ACSS) 47±1 °C / Corrosion Test (CASS)63±1 °C | ||||||||
Lab Capacity(L) | 110 | 270 | 500 | 800 |
|
For Products resistant to pressure and air tightness testing, A PCT pressure Accelerated Aging Test Chamber could help you=>
Model | PCT - 35 | PCT - 45 | PCT - 55 | PCT - 65 | |
Internal Dimension Φ×D (mm) | 300×450 | 450×550 | 550×650 | 650×750 | |
External Dimension Φ×D (mm) | 800×1250×930 | 960×1380×1050 | 1050×1450×1100 | 1150x1600x1500 | |
Temperature Range of Saturated Steam (Operating temperature) | (Temperature Rangeof Saturated Steam:100ºC~135ºC) ,Temperature Range: 120ºC,100Kpa/ 133ºC 200 Kpa;(143ºC is special order) | ||||
Relative Pressure/ Absolute Pressure | Relative pressure: display values indicated on the pressure gaugeAbsolute pressure: Value that add 100 Kpa based on display values indicated on the pressure gauge (The actual value in the inner box) |