-70 Deg C Tempearture Humidity Testing Walk-in Stability Chamber with 20%~98 R.H.
Equipment Summary:
ASLi Walk-in Stability Chamber is consist of Control Panel, electrical panels, moisturizing plate blower, heater, humidifier, freezer. It provides a large spare to test the temperature and humidity for large-scale parts, semi-finished products, it applied to test products that large-scale or the quantity more, such as: computer terminals, vehicle parts.
Corresponding Standard:
1. GB11158 Technical conditions for high-temperature testing room
2. GB10589-89 Technical conditions for low-temperature testing room
3. GB/T10586-89 technical conditions for humidity testing room
4. GB/T2423.1-2001 testing methods for low-temperature
5. GB/T2423.2-2001 testing methods for high-temperature
6. GB/T2423.3-93 technical conditions for humidity testing room
7. GB/T2423.4-93 testing method for alternating hot and humid
8. IEC60068-2-1.1990 testing methods for low-temperature
9. IEC60068-2-2.1974 testing methods for high-temperature
10. GJB150.3 High-temperature test
11. GJB150.4 Low-temperature test
12. GJB150.9 muggy test
13. GB/T2423.22 temperature test
Applicable Industry:
used in defense industry, aerospace industry, automation components, automotive parts, electrical and electronic parts, plastics, chemical, pharmaceutical industries and related products
Walk in stability environmental rooms technical parameters:
Model | TH-80 (A~F) | TH-150 (A~F) | TH-225 (A~F) | TH-408 (A~F) | TH-800 (A~F) | TH-1000 (A~F) |
Internal Dimension WxHxD (mm) | 400x500x 400 | 500x600x 500 | 600x750x 500 | 600x850x 800 | 1000x1000x 800 | 1000x1000x 1000 |
External Dimension WxHxD (mm) | 950x1650 x950 | 1050x1750 x1050 | 1200x1900 x1150 | 1200x1950 x1350 | 1600x2000 x1450 | 1600x2100 x1450 |
Temperature Range | Low Temperature(A:25°C B:0°C C:-20°C D:-40°C E:-60°C F:-70°C) High Temperature 150°C | |||||
Humidity Range | 20%~98%R.H.(10%-98% R.H. / 5%-98% R.H.,is optional , need Dehumidifier) | |||||
Distribution Uniformity of temperature and humidity | ±2.0°C; ±3.0% R.H. | |||||
Control Accuracy of Temp. and Humi. | ±0.5°C; ±2.5% R.H. | |||||
Temperature Humidity Control Chart | | |||||
Temperature Rising /Falling Velocity | Rising approx. 0.1~3.0°C/min; Falling approx. 0.1~1.5°C/min; ( Falling >1.5°C/min is optional) | |||||
Inner and Outer Material | Interior is SUS 304# stainless steel, exterior is stainless steel or see cold-rolled steel with paint coated. | |||||
Insulation Material | Resistant to high temperature, high density, formate chlorine, ethyl acetum foam insulation materials | |||||
Cooling System | Wind cooledor water cooled; single segment compressor for -40°C, double segment compressor for -70°C | |||||
Protection Devices | Fuse-free switch, overloading protection switch for compressor, high and low voltage coolant protection switch, over-humidity and over-temperature protection switch, fuses, fault warning system, water short storage warning protection | |||||
Optional Accessories | Inner door with operation hole , Recorder, Water Purifier, Dehumidifier | |||||
Compressor | French Tecumseh Brand, Germany Bizer Brand | |||||
Power | AC220V 50/60HZ , AC380V 50/60HZ | |||||
Weight (Kg) | 150 | 180 | 250 | 320 | 400 | 450 |