Professional Manufacturer High Low Temperature humidity Climate Test Chambers
Model | TH-80(A~F) | TH-150(A~F) | TH-225(A~F) | TH-408(A~F) | TH-800(A~F) | TH-1000(A~F) |
Internal Dimension WxHxD (mm) | 400x500x400 | 500x600x500 | 600x750x500 | 600x850x800 | 1000x1000x800 | 1000x1000x1000 |
External Dimension WxHxD (mm) | 950x1650x950 | 1050x1750x1050 | 1200x1900x1150 | 1200x1950x1350 | 1600x2000x1450 | 1600x2100x1450 |
Temperature Range | Low Temperature(A:25°C B:0°C C:-20°C D:-40°C E:-60°C F:-70°C) High Temperature 150°C | |||||
Humidity Range | 20%~98%R.H.(10%-98% R.H. / 5%-98% R.H.,is optional , need Dehumidifier) | |||||
Distribution Uniformity of temperature and humidity | ±2.0°C; ±3.0% R.H. | |||||
Control Accuracy of Temp. and Humi. | ±0.5°C; ±2.5% R.H. | |||||
Temperature Humidity Control Chart |
| |||||
Temperature Rising /Falling Velocity | Rising approx. 0.1~3.0°C/min; Falling approx. 0.1~1.5°C/min; ( Falling >1.5°C/min is optional) | |||||
Inner and Outer Material | Interior is SUS 304# stainless steel, exterior is stainless steel or see cold-rolled steel with paint coated. | |||||
Insulation Material | Resistant to high temperature, high density, formate chlorine, ethyl acetum foam insulation materials | |||||
Cooling System | Wind cooledor water cooled; single segment compressor for -40°C, double segment compressor for -70°C | |||||
Protection Devices | Fuse-free switch, overloading protection switch for compressor, high and low voltage coolant protection switch, over-humidity and over-temperature protection switch, fuses, fault warning system, water short storage warning protection | |||||
Optional Accessories | Inner door with operation hole , Recorder, Water Purifier, Dehumidifier | |||||
Compressor | French Tecumseh Brand, Germany Bizer Brand | |||||
Power | AC220V 50/60HZ , AC380V 50/60HZ | |||||
Weight (Kg) | 150 | 180 | 250 | 320 | 400 | 450 |
Corresponding Standard:
1. GB11158 high-temperature testing condition
2. GB10589-89 low-temperature testing condition
3. GB10592-89 high-low-temperature testing condition
4. GB/T10586-89 humidity testing condition
5. GB/T2423.1-2001 low-temperature testing condition
6. GB/T2423.2-2001 high-temperature testing condition
7. GB/T2423.3-93 humidity testing condition
8. GB/T2423.4-93 alternating temperature testing machine
9. GB/T2423.22-2001 temperature testing method
10. IEC60068-2-1.1990 low-temperature testing method
11. IEC60068-2-2.1974 high-temperature testing method
12. GJB150.3 high-temperature test
13. GJB150.4 low-temperture test
14. GJB150.9 humidity test
Applicable Industries:
High And Low Constant Temperature Humidity Test Chamber/Temperature Test Chamber applied to control the product quality, such as electronic, plastic products, electrical appliances, instruments, food, vehicles, metals, chemicals, building materials, aerospace, medical care and so on.
ASLi main test equipments:
Environmental chambers, temperature (humidity) chamber, Thermal shock chamber, PCT /Hast chamber (Highly accelerated stress test chamber), ESS chamber, Walk in stability chamber, Vacuum oven,
Electrodynamic vibration shaker, mechanical shock tester, environmental combined vibration chamber, etcGB12831-86 Vulcanized rubber artificial climate (xenon lamp) Aging Tester