1 Product Name
1-1 Product Name: Customized Walk In Climate Chamber Temperature Humidity Test Chamber
2 Main Technical Parameters
2-1 Dimension: According to customer's requirements
2-2 Material : SUS#304ss
2-3 Temperature :-40°C~150°C (according to customer's requirements)
2-4 Temperature Indication Resolution: ±0.1°C
2-5 Temperature Control Accuracy: ±0.5°C
2-6 Temperature distribution uniformity:±2°C
2-6 Humidity: 20%~98%R.H (according to customer's requirements)
2-7 Humidity Indication Resolution: ±0.1%R.H
2-8 Humidity distribution uniformity: ± 5.0%R.H
Model | THR-volume (low-temperature options : A ~ F) |
Inner Dimensions(cm) | Customers designated space size and design |
Temperature Range | Low Temperature(A:25°C B:0°C C:-20°C D:-40°C E:-60°C F:-70°C) High Temperature 80°C (80°C ~150°C is optional) |
Humidity Range | 20%~98%R.H.(10%-98% R.H. / 5%-98% R.H ,is a special optional condition, need dehumidifier) |
Indication Resolution/Distribution Uniformity of Temperature & Humidity
| 0.1°C; 0.1% R.H/±2.5°C; ±3.5% R.H. |
Control Accuracy of Temperature and Humidity | ±0.5°C; ±2.5% R.H. |
Temperature Rising/Falling Velocity | Temperature rising approx. 0.1~3.0°C/min temperature falling approx. 0.1~1.0°C/min; ( The Falling Velocity Min.1.0°C /min is a optional) |
Cooling System | Water cooled |
Protection Devices | Fuse-free switch, overloading protection switch for compressor,high and low voltage coolant protection switch, over-humidity & over-temperature protection switch, fuses, fault warning system, water short storage warning protection |
Optional Accessories | Slope for cart , Recorder, Water Purifier, Dehumidifier |
Compressor | French Tecumseh Brand, Germany Bizer Brand |
Power | AC 380 V(±10%),50/60HZ ,3 ph 5 Lines |
What is the Temperature Humidity Environmental Test Climatic Chamber?
1. It's a very wide range of controlling the temperature and humidity that can fulfil users needs. It is stable, balanced heating and humidification performance, it also can be high accuracy and high stability for temperature and humidity control performance
2. It is equipped with high-precision intelligent thermostat, controller of temperature and humidity using touch-screen display. Optional equiped with temperature and humidity records
3. Refrigeration circuit of temperature testing machine automatically select to operate performance of refrigeration circuits, so that it starts cooling at high-temperature state
4. Door of large walk-in constant temperature and humidity testing machine with large viewing window for observation of the testing sample
5. It is equipped with advanced security, protective device leak circuit breakers, over-temperature protective device, lack phase protective devices and lack water protector
Design Standard of walk in test chamber:
GB/T2423.1-1989 low-temperature testing method
GB/T2423.2-1989 high-temperature testing method
GB/T2423.22-1989 temperature test
GJB150.5-86 temperature impact test
GJB360.7-87 temperature impact test
Customized Walk In Climate Chamber Temperature Humidity Test Chamber Price with Warning System