High And Low Temperature Impact Thermal Shock Test Chamber , Climatic Chamber
Thermal shock occurs when a thermal gradient causes different parts of an object to expand by different amounts. This differential expansion can be understood in terms of stress or of strain, equivalently. At some point, this stress can exceed the strength of the material, causing a crack to form. If nothing stops this crack from propagating through the material, it will cause the object's structure to fail.
Programmable Thermal Shock Test Chamber is used to test the bearing extent of the material structures and composite material in an instant and continuous high temperature and extremely low temperature environment, that is in the shortest time to test its thermal expansion and contraction caused by chemical change or physical harm, which is widely used in metal, plastic, rubber, electronics and other materials and it can be used as an important reference for improving product quality.
The Thermal Shock Test Chamber is widely used in metal, plastic, rubber, electronics and other materials and it can be used as an important reference for improving product quality.
Thermal shock test chamber Specification:
Model | SM-150-2P-A | SM-200-2P-A | SM-300-2P-A | SM-500-2P-A | |
Temperature | Temperature impact range | -65℃~150℃ (A:-45℃~150℃;B:-65℃~150℃;) | |||
Temperature fluctuation | ±1.0℃ | ||||
Low temperature precooling time |
25.0℃~-75.0℃ Within 60 mins 1.0~3.0℃/min |
||||
High temperature preheating time |
25.0℃~150.0℃ Within 45 mins 3.0~7.0℃/min | ||||
Temperature conversion time | 3s | ||||
Temperature recovery time | Within 5 mins | ||||
Material / components |
Internal material | Stainless steel(SUS304) | |||
External material | Cold rolled steel sheet / powder spraying | ||||
Heat insulating material | 100mm thickness polyurethane plate+10mm thickness mineral wool |
||||
Fan | Centrifugal blower | ||||
Compressor | semi-closed | ||||
Condenser | Air cooling, water cooling | ||||
Refrigerant | R404A,R23,R508 | ||||
Evaporator | Fin - and - Tube Heat Exchanger | ||||
Heater | Nickel chromium alloy heating wire | ||||
Size | Interior size(mm) W*H*D |
500*600*500 | 650*460*670 | 960*460*670 | 960*650*800 |
Outer size(mm) W*H*D |
1250*2530*1650 | 1400*2250*1850 | 1750*2250*1850 | 1750*2630*1980 | |
Volume(L) | 150L | 200L | 300L | 500L | |
Operating ambient temperature | +5 ~ 35℃ | ||||
Power supply | 380V AC 50/60Hz | ||||
Controller | SANWOOD SH5600:Equipped with RS232, RS485 port;(7.0 inch controller) USB data export |