CASS Corrosion Salt Spray Test Chamber , Automotive / Paint / Aerospace Salt Spray Testing Equipment
Features:
1, QSS-270 chamber material is made of P.V.C Sheet, sturdily and will not be out of shape.
2, QSS-270 test chamber is heated from five directions to ensure the temperature is uniformity distributed.
3, QSS-270 spray nozzle is specially made, enable to spray the salt water with considerable speed, then falls on the surface of samples.
4, Hot and moist air keeps the humidity in the QSS-270 test chamber conforms testing request.
5, High precision P.I.D. temperature controller limits the temperature difference within the range of ±0.1℃QSS-270.
QSS-270 Specifications:
Ambient Temp. and Humid. Range: +5℃ ~ +35℃ / <85%RH
Testing Temperature: NSS ACSS 35℃±1℃ / CASS 50℃±1℃
Air Temperature: NSS ACSS 47℃±1℃ /CASS 63℃±1℃
Solution Consistence: NaCi 5%
PH Value: NASS ACSS 6.5~7.2; CASS 3.0~3.2
Temperature Fluctuation: ≦±0.5℃
Temperature Uniformity: ≦2. 0℃
Temperature Deviation: ≦±2.0℃
Spray Quantum: 1.0~2.0(ml/80cm2/h)
Chamber Material: Polyvinyl chloride (PVC)
Heater: Corrosion-resistant titanium tube
Temperature Sensor: Platinum Resistance (PT-100)
Safety Device: Over-temperature protection , leakage protection
Specification:
Model | SM-Y-60D | SM-Y-90D | SM-Y-120D | SM-Y-160D | SM-Y-200D | Inner size | W | 600 | 900 | 1200 | 1600 | 2000 | D | 450 | 600 | 850 | 1000 | 1200 | H | 400 | 500 | 500 | 550 | 600 | Outer size | W | 1130 | 1460 | 2200 | 2600 | 3000 | D | 630 | 910 | 1200 | 1450 | 1650 | H | 1070 | 1280 | 1450 | 1550 | 1600 | Testing room volume(L) | 108 | 270 | 480 | 800 | 1440 | Brine tank capacity(L) | 15 | 25 | 40 | Max current(A) | 5 | 12 | 15 | 18 | 22 | Max Consumption Power(KW) | 1.5 | 2.5 | 3.5 | 5 | 7 | Power supply | AC220V,50HZ | AC380V,50HZ | Operating ambient temperature, humidity | <35℃,<85%RH | Testing room temperature | Brine test method(NSS ACSS)35℃±1℃/Erosion-resistant testing method (CASS)50℃±1℃ | Pressure Pot Temperature | Brine test method(NSS ACSS)47℃±1℃/Erosion-resistant testing method(CASS)63℃±1℃ | Brine solubility | 5% Sodium Chloride Solution or add 0.26 grams copper dichloride in the 5% Sodium | Chloride Solution per liter (CuCl2 2H2O) | PH | 6.5~7.2 3.0~3.2 | Compressed air pressure | 1.00±0.01kgf/cm2 | Spraying amount | 1.0~2.0ml/80cm2/h (Collect 16 hours at least, take their average) | Inside and outside material | Imported corrosion resistant, anti-aging, high strength PVC board | Heater | Corrosion resistance U type titanium tube | Temperature controller | LED digital display temperature controller, touch screen controller | Spraying mode | Continuous,intermittent spraying | Defrosting device | No | Yes | Safety device | Over temperature protection switch, leakage protection, status warning lamp | |