Solid Walk-In Temperature And Humidity Chamber
Feature
Cooling unit.
Comprising the refrigeration equipment and humidification systems required for the control of the temperature and air humidity insidethe walk-in chamber. The basic version requires either mains water or tower water for cooling.
Air Treatment Unit
Powerful fans draw the chamber air across the heat exchangers for cooling and dehumidification, heaters and control sensors before recirculating the conditioned air back into the chamber. A Pt100 sensor (temperature) and a capacitive probe (humidity) is used for control.
User interface.
The control system interface is placed near the door for all the versions of the walk-in chamber. It comprises:
- Emergency STOP push button.
- Touch panel programmer / controller.
- Serial interface RS 232/422
- Software + personal computer (optional).
Test room.
Vapour tight prefabricated panels suitable for multiple assembly and take down operations, AISI 304 interior, blue plastic coated zincor steel exterior. Insulation thickness: 120 mm.
Advantages.
- Reduction in the lead-time for chamber production.
- Improved cost-effectiveness of the equipment.
- The facility to use the same combination of plant unit and air handling system on walk-in chambers which have:
- Different geometry
- Different temperature rates
- Different minimum and maximum temperature limits
- Different thermal load
- Easy to assemble on site.
- Easy to disassemble, relocate and rebuild the equipment, if necessary.
- Possibility to upgrade or refurbish existing facilities by using the plant unit / air handling system / user interface without requiring major reconstruction work.
Specification:
Model | SMC-080-CC-WT | SMC-120-CC-WT | SMC-160-CC-WT | SMC-250-CC-WT | SMC-340-CC-WT | SMC-400-CC-WT | Temperature | Temperature control range | -65℃~80℃(+15℃)(A:0℃~80℃;B:-20℃~80℃;C:-40℃~80℃;D:-65℃~80℃) | Temperature fluctuation | ±0.5℃ | Cooling rate | 80.0℃~-65.0℃ Within 110 mins 1.0~2.0℃/min | Heating rate | -65.0℃~80.0℃ Within 70 mins 2.0~5.0℃/min | Temperature uniformity | ±2.0℃ (-40.0℃~80.0℃) | ±2.5℃ (-40.0℃~-65.0℃) | Humidity | Humidity control range | 20.0%RH~95.0%RH | Humidity fluctuation | ±1.5% RH | Humidity uniformity | ±3.0%RH | Material / | Internal material | Stainless steel(SUS304) | components | External material | Cold rolled steel sheet / powder spraying | | Heat insulating material | 100mm thickness polyurethane plate+10mm thickness mineral wool | | Fan | Centrifugal blower | | Compressor | Semi-closed Germany Bock, Germany Bitzer | | Condenser | Water-cooled | | Refrigerant | R404A,R23,R508 | | Evaporator | Fin - and - Tube Heat Exchanger | | Heater | Nickel chromium alloy heating wire | | Humidifier | Steam humidifier | Size | Interior size(mm) | 1970*2100*1970 | 3020*2100*1970 | 4070*2100*1970 | 3020*2100*4070 | 4070*2100*4070 | 5120*2100*4070 | W*H*D | Outer size(mm) | 2170*2350*3500 | 3220*2350*3500 | 4270*2350*3500 | 4650*2350*4270 | 5720*2350*4270 | 5320*2350*6150 | W*H*D | Volume(m³) | 8.0m³ | 12.0m³ | 16.0m³ | 25.0m³ | 34.0m³ | 40.0m³ | Operating ambient temperature | +5 ~ 35℃ | Power supply | 380V AC 50/60Hz | Controller | Standard: South Korea TEMI-1500 Optional: South Korea TEMI-2500,South Korea TEMI-2700 | |
Product Catalog:
Large Temperature (& Humidity) Test Chamber.pdf