High And Low Temperature Chamber For Thermal Cycling Test
Application:
examine and determine the storage and working performance of electronic, electrical, automobile electrical appliances and materials etc, under high and low temperature environment conditions, which is for schools, factories, war industries, searching departments and other units
Model | SMC-80-CC-FB | SMC-150-CC-FB | SMC-225-CC-FB | SMC-408-CC-FB | SMC-800-CC-FB | SMC-1000-CC-FB | SMC-1500-CC-FB | |
Temperature | Temperature control range | -70℃~180℃ (A:0℃~180℃;B:-20℃~180℃;C:-40℃~180℃;D:-70℃~180℃) | ||||||
Temperature fluctuation | ±0.5℃ | |||||||
Cooling rate | 180.0℃~-70.0℃ Within 100 mins 1.0~3.0℃/min | |||||||
Heating rate | -70.0℃~180.0℃ Within 60 mins 3.0~5.0℃/min | |||||||
Temperature uniformity | ±1.5℃ (-40.0℃~100.0℃) | |||||||
±2.0℃ (100.1℃~180.0℃or-40.0℃~-70.0℃) | ||||||||
Humidity | Humidity control range | 10.0%RH~98.0%RH (60℃ above corresponds to 10%RH) | ||||||
Humidity fluctuation | ±1.0% RH | |||||||
Humidity uniformity | ±2.0%RH | |||||||
Material / components | Internal material | Adopts 1.2mm thickness stainess steel(SUS304) | ||||||
External material | Adopts 1.2mm thickness Cold rolled steel sheet / powder spraying | |||||||
Heat insulating material | 100mm thickness polyurethane plate+10mm thickness mineral wool | |||||||
Fan | Centrifugal blower | |||||||
Compressor | Semi-closed Germany Bock, Germany Bitzer | |||||||
Condenser | Air cooling, water cooling | |||||||
Refrigerant | R404A,R23,R508 | |||||||
Evaporator | Fin - and - Tube Heat Exchanger | |||||||
Heater | Nickel chromium alloy heating wire | |||||||
Humidifier | Steam humidifier | |||||||
Options | Standard configuration | 2 ∅100MM pressure relief port, 4 explosion-prood chains | ||||||
Multipoint temperature monitor | Adopts Sanwood developed controller, which can be used to acquire surface temperature points of multiple products | |||||||
C02 fire extinguisher | Automatic fire extinguishing and automatic shutdown of the machine to protect the equipment from burning | |||||||
C0, H2 gas detector | When the battery will produce gas, it will detect gas solubility and discharge to outdoor when it exceeds the standard | |||||||
Exhaust valve | When the test sample produces harmful gas, ventilate and exhaust internally | |||||||
Size | Interior size(mm) W*H*D | 500*500 *400 | 500*600 *500 | 500*750 *600 | 800*850 *600 | 1000*1000 *800 | 1000*1000 *1000 | 1200*1000 *1250 |
Outer size(mm) W*H*D | 700*1680 *1180 | 700*1720 *1275 | 700*1930 *1290 | 1000*2050 *1400 | 1200*2100 *1590 | 1200*100 *1780 | 1400*2100 *2030 | |
Volume(m³) | 80L | 150L | 225L | 408L | 800L | 1000L | 1500L | |
Weight | 280 | 380 | 450 | 620 | 680 | 840 | 955 | |
Operating ambient temperature | +5 ~ 35℃ | |||||||
Power supply | 220V AC 50/60Hz 22A | 220V AC 50/60Hz 31A | 220V AC 50/60Hz 33A | 380V AC 50/60Hz 17A | 380V AC 50/60Hz 25A | 380V AC 50/60Hz 27A | 380V AC 50/60Hz 50A | |
Controller | Standard: South Korea TEMI-1500 Optional: South Korea TEMI-2500,South Korea TEMI-2700 |
Product Catalog:
Temperature and Humidity Test Chamber .pdf