Temperature Humidity Vibration Combined Test Chamber
1. Temperature Humidity Vibration Combined Test ChamberApplications
This equipment complied with national standard,able to satisfy special testing requirements ,is widely applied for electronic and electric products, automotive parts ,components and materials by high low constant temperature ,temperature change,shock,damp heat vibration etc combined environment simulation reliability test .2. Standard Compliance
2. Temperature Humidity Vibration Combined Test ChamberManufacturing standard :
GB/T10586-2006 Specifications for damp heat chambers
GB/T10592-1989 Specification for low/high temperature test chambers
3. Temperature Humidity Vibration Combined Test ChamberInspection Standard :
GB/T5170.21996 Inspection methods for basic parameters of environmental testing equipments for electric and electronic products. Temperature testing equipments;
GB/T5170.51996 Inspection on methods for basic parameters of environmental testing equipments for electric and electronic products--Damp heat testing equipments
Model | Unit | 4060-5 | 7060-5 | 4120-5 | 7120-5 | 4220-5 | 7220-5 |
SMA Series temperature) | 4060-10 | 7060-10 | 4120-10 | 7120-10 | 4220-10 | 7220-10 | |
SMV Series( humidity) | 4060-15 | 7060-15 | 4120-15 | 7120-15 | 4220-15 | 7220-15 | |
Test volume | (L) | 600 | 1200 | 2200 | |||
Temperature test specification | |||||||
temperature range | ℃ | -40/+180 | -70/+180 | -40/+180 | -70/+180 | -40/+180 | -70/+180 |
temperature fluctuation | ℃ | ±0.1~±0.8 | |||||
Temperature uniformity | ℃ | ±0.5~±2.0 | |||||
Temperature rate | ℃/min | 5℃/min,10℃/min,15℃/min,20℃/min,25℃/min,30℃/min,35℃/min,40℃/min, | |||||
Climate test specification | ( SMV series) | ||||||
temperature range | ℃ | +10~+95 | |||||
temperature fluctuation | ℃ | ±0.1~±0.5 | |||||
temperature fluctuation | ℃ | ±0.5~±1.0 | |||||
humidity range | ℃/min | 10-95(98%r,h. When used in conjunction with the Blind) | |||||
humidity fluctuation | ℃/min | ±1~±3 | |||||
dew-point temperature | ℃ | +4to+94(C14 When used in conjunction with the Blind)/+4to+59( When used with a vertical perforated plate)/+4to+40( when used With horizontal hole bottom plate) | |||||
The maximum size of the vertical perforated plate | mm | max .Φ710 | max .Φ1000 | max .Φ1280 | |||
The maximum size of the bottom plate | mm | max.700×700 | max.1000×1000 | max.1200×1200 | |||
Test Chamber internal dimensions | (W*D*H)mm | 800×800×950 | 1100×1100×950 | 1400×1400×1100 | |||
Test Chamber external dimensions | (W*D*H)mm | 1225×2890×2150 | 1525×3590×2150 | 1825×3950×2300 | |||
Power | 400V±10%,50HZ,3/N/PE | ||||||
Rated power | KW | 11/16/20 | 14/20/24 | 21/24/30 | 24/26/32 | 26/35/54 | 34/44/65 |
cooling method | Water-cooled |