CE listed explosion proof temperature humidity test chamber
Product Description
Mainly used in battery overcharge and over discharge, charge and discharge test, the battery is placed in the explosion-proof box, external charge-discharge tester. Protection for the operator and the instrument.
Technical Specification
Model | SMC-80-CC-FB | SMC-150-CC-FB | SMC-225-CC-FB | SMC-408-CC-FB | SMC-800-CC-FB | SMC-1000-CC-FB | SMC-1500-CC-FB | Temperature | Temperature control | -70℃~180℃ | range | (A:0℃~180℃;B:-20℃~180℃;C:-40℃~180℃;D:-70℃~180℃) | Temperature fluctuation | ±0.5℃ | Cooling rate | 180.0℃~-70.0℃ Within 100 mins | 1.0~3.0℃/min | Heating rate | -70.0℃~180.0℃ Within 60 mins | 3.0~5.0℃/min | Temperature uniformity | ±1.5℃ (-40.0℃~100.0℃) | ±2.0℃ (100.1℃~180.0℃or-40.0℃~-70.0℃) | Humidity | Humidity control range | 10.0%RH~98.0%RH (60℃ above corresponds to 10%RH) | Humidity fluctuation | ±1.0% RH | Humidity uniformity | ±2.0%RH | Material / | Internal material | Adopts 1.2mm thickness stainess steel(SUS304) | components | External material | Adopts 1.2mm thickness Cold rolled steel sheet / powder spraying | | Heat insulating material | 100mm thickness polyurethane plate+10mm thickness mineral wool | | Fan | Centrifugal blower | | Compressor | Semi-closed Germany Bock, Germany Bitzer | | Condenser | Air cooling, water cooling | | Refrigerant | R404A,R23,R508 | | Evaporator | Fin - and - Tube Heat Exchanger | | Heater | Nickel chromium alloy heating wire | | Humidifier | Steam humidifier | Options | Standard configuration | 2 ∅100MM pressure relief port, 4 explosion-prood chains | Multipoint temperature | Adopts Sanwood developed controller, which can be used to acquire surface temperature points of multiple products | monitor | C02 fire extinguisher | Automatic fire extinguishing and automatic shutdown of the machine to protect the equipment from burning | C0, H2 gas detector | When the battery will produce gas, it will detect gas solubility and discharge to outdoor when it exceeds the standard | Exhaust valve | When the test sample produces harmful gas, ventilate and exhaust internally | Size | Interior size(mm) | 500*500 | 500*600 | 500*750 | 800*850 | 1000*1000 | 1000*1000 | 1200*1000 | W*H*D | *400 | *500 | *600 | *600 | *800 | *1000 | *1250 | Outer size(mm) | 700*1680 | 700*1720 | 700*1930 | 1000*2050 | 1200*2100 | 1200*100 | 1400*2100 | W*H*D | *1180 | *1275 | *1290 | *1400 | *1590 | *1780 | *2030 | Volume(m³) | 80L | 150L | 225L | 408L | 800L | 1000L | 1500L | Weight | 280 | 380 | 450 | 620 | 680 | 840 | 955 | Operating ambient temperature | +5 ~ 35℃ | Power supply | 220V AC 50/60Hz 22A | 220V AC 50/60Hz 31A | 220V AC 50/60Hz 33A | 380V AC 50/60Hz 17A | 380V AC 50/60Hz 25A | 380V AC 50/60Hz 27A | 380V AC 50/60Hz 50A | Controller | Standard: South Korea TEMI-1500 Optional: South Korea TEMI-2500,South Korea TEMI-2700 | |
Controller SH-5600,The control panel is provided with USB or RS232 port, a battery surface temperature detection display light( will be divided into three level alarm), a battery fault alarm reminder, a harmful gas alarm, an exhaust indication light, an emergency stop switch, outfire indication light and over temperature protection
Adopting explosion-proof lock and chain on the both sides of door to effectively prevent the door from bursting and hurting the operator when testing product exploded.

Design explosion-proof pressure relief port according to chamber size , the automatic / manual exhaust port, standard pressure limit is 0.104 MPa, quickly open the fan in the battery explosion, or burst explosion pressure outlet to exhaust high pressure gas, preventing people from getting injured.
Product Catalog:
High and Low Temperature Explosion-proof Test Cham...