Specifications
Brand Name :
SANWOOD
Model Number :
SM-4315A
Certification :
CE
Place of Origin :
China
MOQ :
1
Payment Terms :
T/T
Supply Ability :
50 sets per month
Delivery Time :
1 week
Packaging Details :
Sanwood standard package: Wooden case
Standard :
EN149 GB2626 YY0469 GB19083 CFR42-84
Specimen :
Melt Blown, Respirator, Facepiece, Mask
Aerosol type :
NaCl
aerosol particle sensor :
Laser scattering particles counter
test fixture :
fixtures for half-mask, facemask, respirator
Description

Multi-Channel Particle Filtration Efficiency Tester PFE test machine

MODEL: SM4315A

Multi-Channel Particle Filtration Efficiency Tester is used to test the filtration level of aerosol particles by respirator filter element under certain environmental conditions.

The aerosol particles (sodium chloride) with a certain concentration and particle size distribution are generated by the aerosol generator, and pass through the tested sample at the specified air flow rate. The concentration of the particles before and after the test sample is tested, and the filtration efficiency of the tested sample to the particles is evaluated by the percentage of the decrease of the particle concentration.

SM4315A tester adopts high-efficiency aerosol generator, high-precision laser multi-channel aerosol particle sensor, precision differential pressure sensor and precision flowmeter. It is controlled by microcomputer to precisely control the air flow and aerosol concentration

By replacing the test head, SM4315A can test the filtration efficiency of masks, respirator and protective clothing, and one machine is multi-purpose.

SM4315A can also test the suction resistance of the sample.

Testing Scope:

Medical protective mask, Daily protective mask, Disposable respirator, Half mask respirator, Full mask respirator, Protective clothing, Melt blown cloth, etc.

Testing Standards:

GB2626 6.3 GB 19082 5.7 GB 19083 5.4 GB/T 32610 Appendix A
YY 0469 5.6.2 EN 143 8.7 EN 149 8.11 EN 13274-7
JIS T8151 5.1 CFR 42.84 84.181

Product features:

1. The flow range is 0-100l / min, the accuracy is ± 2%, and the resolution is 0.1L/min;

2. The flow rates cover many worldwide test standards;

3. The pressure detection range is 0Pa ~ 1000Pa, the accuracy is 1%, and the resolution is 0.1Pa;

4. Concentration detection range: (0.001-100) mg / L, 0.001 mg / L (0.001-100mg/m3, 0.001mg/m3) ;

5. Automatic control of aerosol generation;

6. Automatic control of aerosol concentration;

7. Salt aerosol generator;

8. Built in high-precision, multi-channel laser scattering particles (aerosol particle sensor);

9. Particle size measurement range: 0.3 mm, 0.5 mm, 0.7 mm, 1.0 mm, 2.5 mm, 5.0 mm;

10. Six Chanel (0.3 mm, 0.5 mm, 0.7 mm, 1.0 mm, 2.5 mm, 5.0 mm) particle filtration efficiency display;

11. Aerosol concentration display;

12. Self-Clean Program built-in;

13. A variety of clamps, suitable for testing masks, respirators and protective clothing, melt blown cloth;

14. Pneumatic clamp;

15. Built-in antistatic device;

16. Built-in HEPA filter;

17. Built-in clean air source;

18. Touch screen control, simple operation;

19. Thermal printer, automatic printing of test data.

PFE Mask Test Machine

Send your message to this supplier
Send Now

PFE Mask Test Machine

Ask Latest Price
Brand Name :
SANWOOD
Model Number :
SM-4315A
Certification :
CE
Place of Origin :
China
MOQ :
1
Payment Terms :
T/T
Contact Supplier
PFE Mask Test Machine
PFE Mask Test Machine

Guangdong Sanwood Technology Co.,Ltd

Active Member
8 Years
Since 1995
Business Type :
Manufacturer
Total Annual :
5000000-8000000
Employee Number :
100~200
Certification Level :
Active Member
Contact Supplier
Submit Requirement