4.5L Liquid to Liquid Thermal Shock Chamber Fluorocarbon oil Thermal Shock Chamber
Test Space | 2.6L |
Specimen box size | 120*120*150mm |
Liquid Tank Size | 250*350*400mm |
External size | 1000mm*17500mm*1900mm |
Liquid test medium | Fluorocarbon oil |
Power supply | AC380V±10%,50Hz±1 |
Maximum system power | 15KW |
Maximum system current | 27A |
Cooling Method | Water-cooled (refrigerating unit) |
Liquid temperature shock test parameters | Low temperature liquid impact test range High temperature liquid impact test range | -65℃~0℃ +70℃~+150℃ |
Temperature fluctuation | ±0.3℃~±1.0℃ | |
Temperature uniformity | ±0.5℃~±2.0℃ | |
The temperature deviation | <±2℃ | |
High temperature liquid tank liquid preheating | Temperature setting range | +70℃~+200℃ Heating time: about 80 minutes from room temperature to +200 ℃ |
Low temperature liquid tank liquid precooling | Temperature setting range | ﹣80℃~0℃ Cooling time: about 90 minutes from room temperature to -80℃ |
Air conditioning room environment | Temperature < 25℃; Relative humidity < 65%RH | |
Temperature recovery time | <5min | |
Temperature conversion time | <10sec | |
Standard | GB2423.1 GB10589-89 GJB150.3-86 IEC68-2-14 MIL-STD-883 MIL-STD-810F MIL-STD-202F |