Optional APP Mobility Management Walk in Environmental Test Chamber
The test chamber is suitable for large size or a large number of machine products, parts, materials for high temperature, low temperature, high low temperature cycle test, and humid heat test. It is mainly used to simulate the product under the combined conditions of climate temperature and humidity or under the changing conditions of ambient temperature and humidity to detect whether the adaptation
ability and characteristics of the product change.
Test methods for environmental test equipment for electrical and electronic products
-- Temperature test equipment
Test methods for environmental test equipment for electrical and electronic products
-- Humidity and heat test equipment
JJF1101-2003 environmental test equipment temperature, humidity calibration specification
Temperature Chambers | ETZ8/4010 | ETZ12/4010 | ETZ17/4010 | ETZ28/4010 |
Climate Chambers | ECZ8/010 | ECZ12/010 | ECZ17/010 | ECZ28/010 |
Temperature Climate Cycling Chambers | ETCZ8/4010 | ETCZ12/4010 | ETCZ17/4010 | ETCZ28/4010 |
Test Space Volume (m³) | 8 | 12 | 17 | 28 |
Test Space Dimension (mm) | 2000W*2000D*2056H | 2000W*2000D*3040H | 2250W×2500D×3032H | 2250W*2500D*5000 |
External Dimension (mm) | 2240W*2240D*3800H | 2240W*2240D*4780H | 2490W*2740D*4900H | 2490W*2740D*6860 |
Floor Load (N/m³) | 30000 ETZ Series: -60,-40 / +80,+100,+150, +180 optional | |||
Temp. Range (℃) (NoLoad) | ECZ Series: 0 / +80,+100 optional | |||
Humid. Range (%RH) | ETCZ Series: -60,-40 / +80,+100,+150 optional | |||
Dewpoint Temp. Range (℃) | 15~95 (ETZ,ETCZ Series) +4~+59 / +4~+95 Heating /Cooling Rate (IEC60068-3-5) | |||
Level 1 (K/min) | 4.5 | 3.7 | 2.7 | 1.7 |
Level 2 (K/min) | 5.5 | 4.5 | 3.2 | 2.0 |
Temp. Constancy (K) | ±0.1~±0.5 (IEC60068-3-5) | |||
Temp.Homogeneity (K) | ±0.5~±3.0 (IEC60068-3-5) | |||
Humid. Constancy Entry (%RH) | ±1.0~±5.0 (IEC60068-3-5) (ECZ, ETCZ Series) | |||
Door Dimension Power(mm) | 900W×1900H(Single door) , 2000W*2000H (Double door) | |||
Power | AC 380V±10%, 50HZ , 3/N/PE |
Options Accessories | Standard Version |
Independent sensors for specimen protection (NE60519-2.1993) | 1 Entry port Φ100mm |
1 Entry port Φ50mm | 1 Silicon stopper for entry port |
Drier filter for compressingair | Automatic water supply |
Ultrasonic Humidifier | 1 Water tank with 20L |
Nitrogen gas auxiliary device | 1 Water filter |
Water-Cooled unit | |
Spare parts package | |
E-management and cyber-software | |
Video monitor system | |
APP for mobility management |