Heating And Cooling Recirculating Air Cooled Water Chiller For Hotel , Office
Model HLWH~ | 110S | 160S | 210S | 240S | 280S | 310S | 340S | ||
Rated Cooling Capacity | Cooling Capacity (KW) | 109 | 155 | 208 | 245 | 283 | 307 | 337 | |
Comp. Input Power (KW) | 34.7 | 47.7 | 63.2 | 71.2 | 82.4 | 89.9 | 99.9 | ||
Rated Heating Capacity | Heating Capacity (KW) | 119 | 167 | 224 | 260 | 301 | 326 | 360 | |
Comp. Input Power (KW) | 32.6 | 44.8 | 59.6 | 67.0 | 77.6 | 84.6 | 94.1 | ||
Refrigerant | R22 | ||||||||
Power Supply | 380V/ 3ph/ 50Hz | ||||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Low & High pressure protection, Low temp. protection, Water flow protection. | ||||||||
Number of Refrigeration Circuit | 1 | ||||||||
Capacity Control (%) | 0, 50, 75, 100 | ||||||||
Refrigerant Charge (Kg) | 30 | 42 | 56 | 68 | 78 | 84 | 93 | ||
Air Cooled Heat Exchanger | Ripple Aluminum Fins Around Copper Pipe | ||||||||
| Dia.of Pipe (inch) | 2-1/2" | 3" | 3" | 3" | 4" | 4" | 4" | |
Water Side Max Pressure (MPa) | 1 | ||||||||
Chilled Water Flow(m3/h) | 18.7 | 26.7 | 35.7 | 42.1 | 48.7 | 52.7 | 58.0 | ||
Water Pressure Drop (kPa) | 28 | 33 | 48 | 55 | 61 | 64 | 66 | ||
Flow of Hot Water(m3/h) | 20.4 | 28.8 | 38.4 | 44.7 | 51.7 | 56.1 | 61.9 | ||
| Air Flow×1000m3/h | 56.8 | 80.4 | 113.6 | 115.2 | 115.2 | 160.8 | 160.8 | |
Power×Qty (KW) | 1.2×4 | 2.0×4 | 1.2×8 | 1.2×8 | 1.2×8 | 2.0×8 | 2.0×8 | ||
Running Noise dB(A) | 75 | 75 | 75 | 75 | 75 | 75 | 75 | ||
Total Weight (Kg) | 1550 | 1960 | 2940 | 3120 | 3300 | 3480 | 3660 | ||
Running Weight(Kg) | 1660 | 2140 | 3160 | 3340 | 3550 | 3730 | 3980 |
1. Rated Cooling Capacity Based on: DB Temperature 35℃/WB Temperature 24℃ |
Chilled water inlet/outlet temp. 12℃/7℃, Fouling factor: 0.088㎡.°C/KW. |
2. Rated Cooling Capacity Based on: DB Temperature 7℃/WB Temperature 6℃ |
Hot water inlet/outlet temp. 40℃/45℃; Hot water range: 45℃~45℃; |
2. Chilled Water Range: 5~20℃; Lowest Ambient Temperature: -5℃~43℃; |
3. Heat recovery unit water in/out temperature: 50℃/55℃; |
4.Changes of Specification for lmprovement May Be made without Notice. |
Feature:
1. Cooling capacity: 109kw~337kw , Heating capacity:
6.. Accept orders for special requirements
7. It can be widely used in hotel, office building, school, hospital, factory and other buildings.
8. Easy installation, simple maintenance;
9. High precise control and reliable operation.
Advantage:
Compact structure, strong and durable , Compact structure, strong and durable