Specifications
Brand Name :
Metalwork
Model Number :
3AV5-12
Certification :
CE, ISO, CCC
Place of Origin :
China
MOQ :
1 set
Price :
Negotiable
Payment Terms :
L/C, T/T
Supply Ability :
100 sets per month
Delivery Time :
20 days
Packaging Details :
Plywooden package
Model :
3AV5-12
Breaking Capacity :
20, 25, 31.5, 40KA
Rated Voltage :
12KV
Rated Current :
630A, 1000A, 1250A, 1600A, 2000A, 2500A, 3150A
Mechanical Life :
20000 times
Motor Voltage :
DC/AC 110V 220V
Types :
withdrawable, stationary, side-mounted
Warranty :
1 year
Description

3AV5-12/1250-31.5 Indoor High-voltage Vacuum Circuit Breaker

3AV5 circuit breaker series is indoor high-voltage switchgear, suitable for rated voltage 12 kV, frequency 50 Hz three-phase power system, as protection and control appliances, with high reliability, easy operation, simple maintenance and other characteristics. The circuit breaker can be used for middle-type switchgear and fixed switchgear as well as oil-free transformation. Because of the special advantages of vacuum circuit breaker, it is especially suitable for frequent operation requiring rated current, or many times to break the short-circuit current. The 3AV5 vacuum circuit breaker has three installation modes: fixed type, extraction type and side mounted. For special requirements, please contact the manufacturer.

Three Phase Indoor Vacuum Circuit Breaker High Voltage Side Mounted AC 50HZ 12KV 3150A

Technical Parameters:

Items Unit Date
Rated voltage

KV

12
Rated impulse withstand voltage 75
Rated short-time power frequency withstand voltage (1min) 42
Rated frequency Hz 50~60
Rated short-circuit breaking current KA 20 25 31.5 40
Rated current A

630 1000

1250

630 1000

1250 1600

1250 1600

2000 2500

1600 2000 2500 3150 4000
Rated short-time withstand current KA 20 25 31.5 40
Rated peak tolerable current 50 63 80 100
Rated short-circuit making current (peak value) 50 63 80 100
Secondary circuit power frequency withstand voltage (1min) V 2000
Rated operation sequence

O-0.3S-CO-180S-CO

O-180S-CO-180S-CO (at 40KA)

Rated single/back-to-back capacitance bank breaking current

Set breaking current

A 630/400 (40KA 800/400)
Rated short-circuit breaking current DC flow percentage ≤35%
Opening time (rated voltage) ms 20-50
Closing time (rated voltage) ms 30-70
Mechanical life times 20000
Rated short-circuit breaking current breaking times times 50 (40KA 30)
Allowable wear accumulate thickness of moving and static contacts mm 3
Rated closing operating voltage v AC110/220 DC110/220
Rated opening operating voltage v AC110/220 DC110/220
Rated voltage of energy storage motor v AC110/220 DC110/220
Rated power of energy storage motor w 80
Contact opening distance mm 11±1
Contact stroke mm 3.5±1
Contact bounce time ms ≤2 (40KA ≤3)

Three - phase opening and closing

heterogeneity

ms ≤2
Average closing speed *1 m/s 0.9-1.3
Average closing speed*2 m/s 0.4-0.8
Main circuit resistance μΩ

≤50 (630A) ≤45 (1250A)

≤35 (1600-2000A) ≤25 (above 2500A)


Send your message to this supplier
Send Now

Three Phase Indoor Vacuum Circuit Breaker High Voltage Side Mounted AC 50HZ 12KV 3150A

Ask Latest Price
Brand Name :
Metalwork
Model Number :
3AV5-12
Certification :
CE, ISO, CCC
Place of Origin :
China
MOQ :
1 set
Price :
Negotiable
Contact Supplier
Three Phase Indoor Vacuum Circuit Breaker High Voltage Side Mounted AC 50HZ 12KV 3150A
Three Phase Indoor Vacuum Circuit Breaker High Voltage Side Mounted AC 50HZ 12KV 3150A
Three Phase Indoor Vacuum Circuit Breaker High Voltage Side Mounted AC 50HZ 12KV 3150A
Three Phase Indoor Vacuum Circuit Breaker High Voltage Side Mounted AC 50HZ 12KV 3150A

METALWORK MACHINERY (WUXI) CO.LTD

Verified Supplier
8 Years
jiangsu, wuxi
Since 2006
Business Type :
Manufacturer, Exporter
Total Annual :
10,000,000-20,000,000
Employee Number :
180~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement