High quality 396W 48V 8.3A Single Output switching power supply AC to DC
Features:
1. Reliable quality and good price
2. High efficiency and low working temperature
3. Built-in EMI filter
4. 100% full-load burn-in test
5. Protection: Over load protection, short circuit protection
Specification:
Model number | S-400-12 | S-400-15 | S-400-24 | S-400-36 | S-400-48 |
DC Output Voltage | 12V | 15V | 24V | 36V | 48V |
Output Voltage Error | ± 2% | ± 2% | ± 1% | ± 1% | ± 1% |
Rated Output Current | 33A | 26.6A | 16.6A | 11A | 8.3A |
Output Current Range | 0-33A | 0-26.6A | 0-16.6A | 0-11A | 0-8.3A |
Ripple and Noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p |
Inlet Stability | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% |
Load Stability | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% |
DC Output Power | 396W | 399W | 398W | 396W | 396W |
Efficiency | 80% | 81% | 83% | 83% | 84% |
Adjustable Range for DC Voltage | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% |
AC Input Voltage Range | 90~132VAC/180~264VAC selected by switch 47~63Hz; 254~370VDC | ||||
Input Current | 6A/115V 3A/230V | ||||
AC Inrush Current | Cold-Start Current: 25A/115V 50A/230V | ||||
Leakage Current | <3.5mA/240VAC | ||||
Overload Protection | 105%~135% Type: Cut Output, Reset: Auto Recovery | ||||
Over Voltage Protection | 115%~135% of the output voltage | ||||
Temperature Coefficient | ± 0.03% /°C (0~50°C) | ||||
Start, Rise, Hold time | 200ms, 100ms, 30ms | ||||
Vibration | 10~500Hz, 2G 10min/1 cycle, a total of 60 minutes, Each axes | ||||
Withstand Voltage | Input and Output Interval: 1.5KVAC, Input and Enclosure: 1.5KVAC, Output and Enclosure: 0.5KVAC | ||||
Isolation Resistance | Input and Output Interval: Input and Enclosure, Output and Enclosure: 500VDC/100M Ohms | ||||
Working Temperature and Humidity | -10°C~+60°C (Refer to Output Derating Curve), 20%~90%RH | ||||
Dimension | 215*115*50 mm | ||||
Weight | 1.15kg | ||||
Safety Standards | GB4949, UL60950, EN60950 | ||||
EMC Standards | Design according to GB9254 EN55022 EN55024 Class A |
1. The testing condition for the parameter above is: 230VAC input, rated load, 25°C 70%RH, Humidity.
2. Error, include the setting error, line stability and load stability.
3. Wave test: adopting "A12" twisted pair wire for 20MHz, and 0.1uF-47uF capacitor short-circuit for interrupting .
4. Inlet Voltage Stability test: when it is over load, the lowest voltage of inlet is representative to the highest voltage .
5. Load stability test: the load is from 0% to 100% .
6. C3.4 must be knocked down.
Dimension unit:mm