Single Output switching power supply 96W 48V 2A Transformer AC to DC Converter
Features:
1. Reliable quality and good price
2. High efficiency and low working temperature
3. Built-in EMI filter
4. 100% full-load burn-in test
5. Protection: Over load protection, short circuit protection
Specification:
Model number | S-100-3 | S-100-5 | S-100-7.5 | S-100-12 | S-100-15 | S-100-24 | S-100-27 | S-100-48 |
DC Output Voltage | 3V | 5V | 7.5V | 12V | 15V | 24V | 27V | 48V |
Output Voltage Error | ± 2% | ± 2% | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% |
Rated Output Current | 20A | 20A | 13.6A | 8.5A | 6.7A | 4.5A | 3.7A | 2A |
Output Current Range | 0-20A | 0-20A | 0-13.6A | 0-8.5A | 0-6.7A | 0-4.5A | 0-3.7A | 0-2A |
Ripple and Noise | 75mVp-p | 75mVp-p | 70mVp-p | 60mVp-p | 60mVp-p | 50mVp-p | 50mVp-p | 50mVp-p |
Inlet Stability | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.3% | ± 0.3% | ± 0.3% | ± 0.2% | ± 0.2% |
Load Stability | ± 0.5% | ± 1% | ± 0.5% | ± 0.3% | ± 0.3% | ± 0.2% | ± 0.2% | ± 0.2% |
DC Output Power | 60W | 100W | 102W | 102W | 100.5W | 108W | 100W | 96W |
Efficiency | 74% | 78% | 80% | 82% | 82% | 85% | 86% | 86% |
Adjustable Range for DC Voltage | 2.85-3V | 4.75-5.5V | 6.75-8.25V | 10.8-13.2V | 13.5-16.5V | 21.6-26.4V | 26-32V | 43.2-52.8V |
AC Input Voltage Range | 85~132VAC/180~264VAC selected by switch 47~63Hz; 255~370VDC | |||||||
Input Current | 2.4A/115V 1.2A/230V | |||||||
AC Inrush Current | Cold-Start Current: 30A/115V, 60A/230V | |||||||
Leakage Current | <1mA/240VAC | |||||||
Overload Protection | 105%~150% Type: Cut Output, Reset: Auto Recovery | |||||||
Over Voltage Protection | .......... | |||||||
Temperature Coefficient | ± 0.03% /°C (0~50°C) | |||||||
Start, Rise, Hold time | 200ms, 100ms, 30ms | |||||||
Vibration | 10~500Hz, 2G 10min, /1 cycle, a total of 60 minutes, Each axes | |||||||
Withstand Voltage | Input and Output Interval: 1.5KVAC, Input and Enclosure: 1.5KVAC, Output and Enclosure: 0.5KVAC | |||||||
Isolation Resistance | Input and Output Interval: Input and Enclosure, Output and Enclosure: 500VDC/100M Ohms | |||||||
Working Temperature and Humidity | -10°C~+60°C (Refer to Output Derating Curve), 20%~90%RH | |||||||
Dimension | 199*98*38 mm | |||||||
Weight | 0.65kg | |||||||
Safety Standards | Meet UL 1012 requirement (Not apply for the mark) | |||||||
EMC Standards | Meet FCC Part 15J Condition class B |
1. The testing condition for the parameter above is: 230VAC input, rated load, 25°C 70%RH, Temperature .
2. Error, include the setting error, line stability and load stability.
3. Wave test: adopting "A12" twisted pair wire for 20MHz, and 0.1uF-47uF capacitor short-circuit for interrupting .
4. Inlet Voltage Stability test: when it is over load, the lowest voltage of inlet is representative to the highest voltage .
5. Load stability test: the load is from 0% to 100% .
Dimension unit:mm