Single Output switching power supply 35W 12V 3A Transformer AC to DC
Features:
1. Reliable quality and good price
2. High efficiency and low working temperature
3. Built-in EMI filter
4. 100% full-load burn-in test
5. Protection: Over load protection, short circuit protection
Specification:
Model number |
S-35-5 |
S-35-12 |
S-35-15 |
S-35-24 |
DC Output Voltage |
5V |
12V |
15V |
24V |
Output Voltage Error |
± 2% |
± 1% |
± 1% |
± 1% |
Rated Output Current |
7A |
3A |
2.4A |
1.5A |
Output Current Range |
0-7A |
0-3A |
0-2.4A |
0-1.5A |
Ripple and Noise |
100mVp-p |
75mVp-p |
75mVp-p |
50mVp-p |
Inlet Stability |
± 0.5% |
± 0.5% |
± 0.5% |
± 0.5% |
Load Stability |
± 1% |
± 0.5% |
± 0.5% |
± 0.5% |
DC Output Power |
35W |
36W |
36W |
36W |
Efficiency |
70% |
76% |
78% |
78% |
Adjustable Range for DC Voltage |
+10%, -5% |
± 10% |
± 10% |
± 10% |
AC Input Voltage Range |
85~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDC |
|||
Input Current |
0.8A/115V 0.45A/230V |
|||
AC Inrush Current |
Cold-Start Current: 18A/115V, 36A/230V |
|||
Leakage Current |
<0.5mA/240VAC |
|||
Overload Protection |
105%~150% Type: Cut Output, Reset: Auto Recovery |
|||
Over Voltage Protection |
.......... |
|||
Temperature Coefficient |
± 0.03% /°C (0~50°C) |
|||
Start, Rise, Hold time |
200ms, 100ms, 30ms |
|||
Vibration |
10~500Hz, 2G 10min, /1 cycle, a total of 60 minutes, Each axes |
|||
Withstand Voltage |
Input and Output Interval: 1.5KVAC, Input and Enclosure: 1.5KVAC, Output and Enclosure: 0.5KVAC |
|||
Isolation Resistance |
Input and Output Interval: Input and Enclosure, Output and Enclosure: 500VDC/100M Ohms |
|||
Working Temperature and Humidity |
-10°C~+60°C (Refer to Output Derating Curve), 20%~90%RH |
|||
Dimension |
129*98*38 mm |
|||
Weight |
0.4kg |
|||
Safety Standards |
Meet UL 1012 requirement (Not apply for the mark) |
|||
EMC Standards |
Meet FCC Part 15J Condition class B |
1. The testing condition for the parameter above is: 230VAC input, rated load, 25°C 70%RH, Humidity .
2. Error, include the setting error, line stability and load stability.
3. Wave test: adopting "A12" twisted pair wire for 20MHz, and 0.1uF-47uF capacitor short-circuit for interrupting .
4. Inlet Voltage Stability test: when it is over load, the lowest voltage of inlet is representative to the highest voltage .
5. Load stability test: the load is from 0% to 100% .
Dimension unit:mm