Specifications
Place of Origin :
China
Brand Name :
Zion communication OR OEM
Certification :
CE, RoHS, VDE, UL, CUL, LPCB
Model Number :
Fire Resistant Cable Unshielded 1.50mm2
MOQ :
20 KM
Packaging Details :
100M, 200M, Plastic Spool, Carton
Delivery Time :
25 working days
Payment Terms :
T/T, L/C
Supply Ability :
1000KM / Month
Conductor :
Solid Bare Copper
Insulation :
Silicone Rubber
Jacket :
FRLS PVC
Color :
Red
Package :
100M, 200M, Plastic Spool, Carton
Description

FRLS Unshielded 1.50mm2 in Red Fire Proof Jacket with Solid Bare Copper Conductor

Quick Detail:

  • Fire Resistant Cable
  • FRLS Unshielded 1.50mm2
  • Bare Copper Conductor
  • Silicone Rubber Insulation
  • Fire Resistance Low Smoke PVC
  • 100M, 200M, Plastic Spool, Carton
  • 180 Minutes under Fire of 750 Degrees without Short-Circuit.
  • MOQ: 20 KM

Description:

KT1435 FRLS Unshielded 1.50mm2 Fire Resistant Cable Bare Copper Silicone Insulation

is a specific type of fire alarm cable Produced by Zion communication. These cables are used for

installation in fire systems for connecting fire alarms etc. The cable can be installed

in dry and moist areas as well for fixed open air installation. This cable type with

electrostatic screening (St) protects the transmission circuits against extern-electrical

interferences. And all these cables comply to:

IEC60331-23-2003

IEC60332-3-22-2005

IEC61034-2-2005

EC60754-1-99

IEC60754-2-99

IEC60331-21:1999

BS EN 61034-2:2005

BS 7629-1:2008

BS EN 50267-2-1:1999

Zion communication using best raw material and best worker to produce KT1435 FRLS Unshielded 1.50mm2 Fire Resistant Cable Bare Copper Silicone Insulation to meet high performance in practical application.

KT1435 FRLS Unshielded 1.50mm2 Fire Resistant Cable Bare Copper Silicone Insulation is packed in 200m Spool, 2 Spools in Carton, then will be layed on pallet to protect the spool and easier carry. Because of good managing methods, Zion communication’S price of KT1435 FRLS Unshielded 1.50mm2 Fire Resistant Cable Bare Copper Silicone Insulation is not high although our quality is really high.

Applications:

These cables are used for installation in fire systems for connecting fire alarms etc.

The cable can be installed in dry and moist areas as well for fixed open air installation.

This cable type with electrostatic screening (St) protects the transmission circuits

against extern-electrical interferences.

KT1435 FRLS Unshielded 1.50mm2 Fire Resistant Cable Bare Copper Silicone Insulation

APPLICATION:
These cables are used for installation in fire systems for connecting fire alarms etc.
The cable can be installed in dry and moist areasas well for fixed open air installation.
This cable type with electrostatic screening (St) protects the transmission circuits
against externelectrical interferences.
Standards:
All these cables comply to:
IEC60331-23-2003
IEC61034-2-2005
IEC60754-2-99
IEC60332-3-22-2005
IEC60754-1-99
IEC60331-21:1999
BS 7629-1:2008
BS EN 61034-2:2005
BS EN 50267-2-1:1999
Fire Testing:
180 minutes under fire of 750 degrees without short-circuit.
ELECTRICAL DATA (AT20OC):
Minimum
Bend Radius
Min.Insulation
resistance
Max.Working
Temperature
Test voltage
(rms value)
Max. Operating
voltage peak value
MΩ/km V V
8×Diameter 200 -15℃~+90℃ 1000 300
TYPES AND MECHANICAL DATA:
Types
sqmm (mm2)
Conductor
BC (mm)
Insulation Level of
twisting
Jacket Matterial OD of
Jacket (mm)
1×2×1.50 1×2×1.35 Silicone FRLS 6.90
2×2×1.50 2×2×1.35 Silicone FRLS 8.00
*Notes Class 1: Solid BC: Bare Copper
Order Informations:
Marking Zion communication KT1435 FRLS Unshielded n×2×1.50MM2 CABLE
Package 100M, 200M, Plastic Spool, Carton
More info. Please contact with us.

Competitive Advantage:

1, From raw materials to final products, we perform intense quality checks to maintain our product quality:

A, Incoming material inspected by QC.

B, Manufacturing Process Control

C: Workers trained daily/weekly/monthly

D: Work instructions manual at each work station

E: 5S system implemented

F: Machine maintenance procedure

G: Quality Control and Final Inspection

The QC staff will check the material, process product

and final product according to the specification or test procedure.

2, Our R&D efforts center on reinforcing and developing element technologies

needed to support the future growth and success for customers and Zion communication.

3, We know customers have urgent needs.

We are skilled at effective communication to interact with customers.

In order to provide prompt service, we can answer for you 7*24 hours.

4, We can Quickly and professionally answer for the inquire

5, More than 1000 kinds of cable, connectors and assembles can be produce and organized from us

6, Intime delivery

FRLS Unshielded 1.50mm2 in Red Fire Proof Jacket with Solid Bare Copper Conductor

Send your message to this supplier
Send Now

FRLS Unshielded 1.50mm2 in Red Fire Proof Jacket with Solid Bare Copper Conductor

Ask Latest Price
Place of Origin :
China
Brand Name :
Zion communication OR OEM
Certification :
CE, RoHS, VDE, UL, CUL, LPCB
Model Number :
Fire Resistant Cable Unshielded 1.50mm2
MOQ :
20 KM
Packaging Details :
100M, 200M, Plastic Spool, Carton
Contact Supplier
FRLS Unshielded 1.50mm2 in Red Fire Proof Jacket with Solid Bare Copper Conductor
FRLS Unshielded 1.50mm2 in Red Fire Proof Jacket with Solid Bare Copper Conductor
FRLS Unshielded 1.50mm2 in Red Fire Proof Jacket with Solid Bare Copper Conductor
FRLS Unshielded 1.50mm2 in Red Fire Proof Jacket with Solid Bare Copper Conductor
FRLS Unshielded 1.50mm2 in Red Fire Proof Jacket with Solid Bare Copper Conductor

HANGZHOU ZION COMMUNICATION CO., LTD

Verified Supplier
10 Years
zhejiang, hangzhou
Since 1999
Business Type :
Manufacturer, Exporter
Total Annual :
80 Million-100 Million
Employee Number :
400~500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement