Specifications
Brand Name :
Kaideli
Model Number :
ECG series
Certification :
CE,ISO9001-2008
Place of Origin :
China
MOQ :
1 Piece
Price :
$100.00 - $1,700.00/sets
Payment Terms :
TT,LC,Western Union
Supply Ability :
2000 Set/Sets per Month
Delivery Time :
10-15 days
Packaging Details :
Wood box packing
Applicable Industries :
Hotels, Building Material Shops, Machinery Repair Shops, Food & Beverage Factory, Farms, Home Use, Retail, Food Shop, Construction works , Food & Beverage Shops
Showroom Location :
Viet Nam, Philippines, Mexico, Thailand, Kazakhstan, Nigeria, Uzbekistan, Tajikistan
Video outgoing-inspection :
Provided
Machinery Test Report :
Provided
Type :
Evaporator
Application :
Refrigeration Parts
Warranty :
1 Year
Color :
Option (White,green,black)
Refrigerant :
Optional
Brand :
Kaideli
Fin space :
4.5-12mm
Test :
2.6Mpa
Cooling capacity :
1.2kw--114kw
Voltage :
220/380v
Package :
Export wooden
Fin material :
Aluminun
Usage :
Freezer
After Warranty Service :
Online support
Local Service Location :
None
Marketing Type :
New Product 2023
After-sales Service Provided :
Video technical support, Field installation, commissioning and training, No after-sales service, Online support
Port :
Ningbo/Shanghai/Guangzhou
Conditon :
New
Description

Product name: Commercial Dual Discharge Glycol Cool Room Chiller Unit 4.5-12mm Fin space

ECG SERIES COMMERCIAL DUAL-DISCHARGE GLYCOL UNIT COOLERS

1. Product description:

ECG series air coolers are designed with ethylene glycol solution as secondary coolant and ultra-thin structure, with air inlet from the bottom and air outlet from two sides. ECG series coolers are mainly used in cold storage that use ethylene glycol solution as secondary coolant. The product has a small installation space and is mainly used in a manned processing room with low temperature glycol solution as the secondary refrigerant. ECG series coolers can be used at 10℃, 0℃ and -18℃ respectively.

This series of products have the following characteristics:

● Casing: Al-Mg alloy sheet with silver powder coating (RAL7001) , it has strong anti-corrosion property and light weight.

● Evaporator end plate adopts aluminum plate, effectively protect copper tube, reduce weight.

● Double water plate design: the outer water plate with hinge structure design, convenient operation; The inner water tray adopts the flume structure of aluminum plate. The condensed water or defrosted water is directly discharged into the outlet of the outer water tray through the inner water tray.

● Coil:copper pipe φ12, the tube spacing is 38.1×33 ,triangle arrangement, heat transfer efficiency is high.

● Corrugated aluminum fins with hydrophilic film, fin spacing of 4.0 and 6.0mm to meet the different temperature requirements of cold storage.

● Fans:external rotor fan, fan specification φ350, working temperature -30~60℃, the number of fans 1 to 4. With high speed and low speed design, can meet different noise requirements.

● Defrosting:standard electric heating defrosting, stainless steel heating pipe are distributed on the coil tube fin and inner water plate, has a good defrosting effect.

● IP65 grade waterproof junction box and waterproof connector, the fan and heating pipe adopt independent wire box ,with better waterproof effect, high reliability.

● The outlet of the air cooler is equipped with schrader alve, which is convenient for users to detect pressure.

● Strict factory pressure test, test pressure 23bar.

2. Standard configuration and options:

Parts Configuration Parts Configuration
Casing Al-Mg alloy sheet with powder coating Fin Aluminum fins
sheet with powder coating Hydrophilic aluminum fins
Galvanized sheet with powder coating Defrosting Air defrosting
Stainless steel plate Electric heating pipe
Fan WEIGUANG motor Water ×
EBM motor Drainpipe hot wire
The wind bucket motor × Wind duct heating belt ×

●:Standard;○:Options;×:Do not choose

3. Technical data sheet:

3.1 Fan standard speed(1420rpm)

3.1.1 Fin spacing 4.0mm

Model

Glycol 25%

T1=-3, T2=2

Tr=10,RH85%

Glycol 34%

T1=-10, T2=-7

Tr=0,RH85%

Surface

Tube

Volume

Airflow Airthrow Connect pipe Weight
Capacity (KW)

Liquid Flow

(m3/h)

Capacity (KW)

Liquid Flow

(m3/h)

m2 dm3 m3/h m Inlet Outlet Drain kg
ECG351/CLN-ET 3.5 0.6 2.6 0.8 13.1 2.5 2200 6 φ22 φ22 G1” 31
ECG351/DLN-ET 4.4 0.8 3.2 1.0 17.5 3.4 2000 6 φ22 φ22 G1” 33
ECG352/CLN-ET 7.1 1.3 5.1 1.6 26.3 4.7 4400 8 φ28 φ28 G1” 51
ECG352/DLN-ET 8.8 1.6 6.3 2.0 35.0 6.3 4000 8 φ28 φ28 G1” 55
ECG353/CLN-ET 10.6 2.0 7.7 2.5 39.4 6.9 6600 10 φ28 φ28 G1” 73
ECG353/DLN-ET 13.1 2.4 9.4 3.0 52.5 9.2 6000 10 φ35 φ35 G1” 79
ECG354/CLN-ET 14.2 2.6 10.2 3.3 52.5 9.1 8800 12 φ35 φ35 G1” 93
ECG354/DLN-ET 17.5 3.2 12.6 4.0 70.0 12.2 8000 12 φ35 φ35 G1” 100

In the table, T1 is the inlet temp. of ethylene glycol solution, T2 is the outlet temp., and Tr is the temp. of cold room.

3.1.2 Fin spacing 6.0mm

Model

Glycol 34%

T1=-10, T2=-7

Tr=0,RH85%

Glycol 50%

T1=-28,T2=-25

Tr=-18,RH95%

Surface

Tube

Volume

Airflow Airthrow Connect pipe Weight
Capacity (KW)

Liquid Flow

(m3/h)

Capacity (KW)

Liquid Flow

(m3/h)

m2 dm3 m3/h m Inlet Outlet Drain kg
ECG351/CDN-ET 2.1 0.7 1.9 0.7 9.0 2.5 2350 6 φ22 φ22 G1” 30
ECG351/DDN-ET 2.6 0.8 2.4 0.8 12.0 3.4 2200 6 φ22 φ22 G1” 32
ECG352/CDN-ET 4.3 1.4 3.9 1.4 18.1 4.7 4700 8 φ28 φ28 G1” 50
ECG352/DDN-ET 5.3 1.7 4.8 1.7 24.1 6.3 4400 8 φ28 φ28 G1” 53
ECG353/CDN-ET 6.4 2.0 5.8 2.0 27.1 6.9 7050 10 φ28 φ28 G1” 71
ECG353/DDN-ET 7.9 2.5 7.2 2.5 36.1 9.2 6600 10 φ35 φ35 G1” 76
ECG354/CDN-ET 8.5 2.7 7.8 2.7 36.1 9.1 9400 12 φ35 φ35 G1” 91
ECG354/DDN-ET 10.6 3.4 9.6 3.4 48.2 12.2 8800 12 φ35 φ35 G1” 97

In the table, T1 is the inlet temp. of ethylene glycol solution, T2 is the outlet temp., and Tr is the temp. of cold room.

3.2 Fan low speed(920rpm)

3.2.1 Fin spacing 4.0mm

Model

Glycol 25%

T1=-3, T2=2

Tr=10,RH85%

Glycol 34%

T1=-10, T2=-7

Tr=0,RH85%

Surface

Tube

Volume

Airflow Airthrow Connect pipe Weight
Capacity (KW)

Liquid Flow

(m3/h)

Capacity (KW)

Liquid Flow

(m3/h)

m2 dm3 m3/h m Inlet Outlet Drain kg
ECG351/CLS-ET 2.9 0.5 1.8 0.6 13.1 2.5 1150 5 φ22 φ22 G1” 31
ECG351/DLS-ET 3.5 0.6 2.1 0.7 17.5 3.4 1300 5 φ22 φ22 G1” 33
ECG352/CLS-ET 5.8 1.1 3.7 1.2 26.3 4.7 2300 7 φ28 φ28 G1” 51
ECG352/DLS-ET 7.0 1.3 4.2 1.3 35.0 6.3 2600 7 φ28 φ28 G1” 55
ECG353/CLS-ET 8.7 1.6 5.5 1.8 39.4 6.9 3450 8 φ28 φ28 G1” 73
ECG353/DLS-ET 10.5 1.9 6.3 2.0 52.5 9.2 3900 8 φ35 φ35 G1” 79
ECG354/CLS-ET 11.6 2.1 7.4 2.4 52.5 9.1 4600 10 φ35 φ35 G1” 93
ECG354/DLS-ET 14.0 2.6 8.4 2.7 70.0 12.2 5200 10 φ35 φ35 G1” 100

In the table, T1 is the inlet temp. of ethylene glycol solution, T2 is the outlet temp., and Tr is the temp. of cold room.

3.2.2 Fin spacing 6.0mm

Model

Glycol 34%

T1=-10, T2=-7

Tr=0,RH85%

Glycol 50%

T1=-28,T2=-25

Tr=-18,RH95%

Surface

Tube

Volume

Airflow Airthrow Connect pipe Weight
Capacity (KW)

Liquid Flow

(m3/h)

Capacity (KW)

Liquid Flow

(m3/h)

m2 dm3 m3/h m Inlet Outlet Drain kg
ECG351/CDS-ET 1.5 0.5 1.3 0.5 9.0 2.5 1300 5 φ22 φ22 G1” 30
ECG351/DDS-ET 1.8 0.6 1.6 0.6 12.0 3.4 1450 5 φ22 φ22 G1” 32
ECG352/CDS-ET 3.1 1.0 2.7 1.0 18.1 4.7 2600 7 φ28 φ28 G1” 50
ECG352/DDS-ET 3.6 1.2 3.1 1.2 24.1 6.3 2900 7 φ28 φ28 G1” 53
ECG353/CDS-ET 4.6 1.5 4.1 1.5 27.1 6.9 3900 8 φ28 φ28 G1” 71
ECG353/DDS-ET 5.4 1.7 4.7 1.7 36.1 9.2 4350 8 φ35 φ35 G1” 76
ECG354/CDS-ET 6.1 2.0 5.4 2.0 36.1 9.1 5200 10 φ35 φ35 G1” 91
ECG354/DDS-ET 7.2 2.3 6.3 2.3 48.2 12.2 5800 10 φ35 φ35 G1” 97

In the table, T1 is the inlet temp. of ethylene glycol solution, T2 is the outlet temp., and Tr is the temp. of cold room.

4. Electrical parameter table:

Model Fan Motor Electric defrosting
Voltage(V) Input(W) Current(A) Speed(r/min) Coil(KW) Tray(KW) Total(KW)
ECG351/**N-ET 380-3 165 0.43 1420 2×0.6 2×0.6 2.4
ECG352/**N-ET 380-3 330 0.86 1420 2×1.1 2×1.1 4.4
ECG353/**N-ET 380-3 495 1.29 1420 2×1.6 2×1.6 6.4
ECG354/**N-ET 380-3 660 1.72 1420 2×2.0 2×2.0 8.0
ECG351/**S-ET 380-3 80 0.32 920 2×0.6 2×0.6 2.4
ECG352/**S-ET 380-3 160 0.64 920 2×1.1 2×1.1 4.4
ECG353/**S-ET 380-3 240 0.96 920 2×1.6 2×1.6 6.4
ECG354/**S-ET 380-3 320 1.28 920 2×2.0 2×2.0 8.0

5.How to select correct evaparator:

Generally,Choose evaporator capacity=cold room cooling capacity *1.15

1.When the cold room temperature is around 0℃, select 4.5mm as fin space.

Evaporator choose=1.0*Q0

2.When the cold room temperature is around -18℃, select 6mm as fin space.

Evaparator choose=1.1*Q0

3.When the cold room temperature is around -25℃, select 9mm as fin space.

Evaparator choose=1.27*Q0

Remarks: The water defrost and hot gas defrost type are also optional.

Customized specification leave me message for details.

6.Want to know other related products?-click picture for detailed specification

Commercial Dual Discharge Glycol Cool Room Chiller Unit 4.5-12mm Fin space

7.How to assure quality? Any procedure?

Our QC department will make sure of each step

Commercial Dual Discharge Glycol Cool Room Chiller Unit 4.5-12mm Fin space

8.Do you factory?
We are factory established in 1995 and through 28years developed,welcomed by all our customers.Because of all your support now we are a big family of more than 300 people,covered 50000 square meters,and your supporting is very important of continuing our dream of eating fresh and healthy food.

Commercial Dual Discharge Glycol Cool Room Chiller Unit 4.5-12mm Fin space

Commercial Dual Discharge Glycol Cool Room Chiller Unit 4.5-12mm Fin space

9.Do you attend exhibition?

Each year we will attend domestic national and foreign exhibition,also we will support our agent to attend exhibition,welcome to join us.

Commercial Dual Discharge Glycol Cool Room Chiller Unit 4.5-12mm Fin space

10.Why choose us

Professional:28 years focus one thing-refrigeration equipments

Commercial Dual Discharge Glycol Cool Room Chiller Unit 4.5-12mm Fin space

Material we use sufficient

Commercial Dual Discharge Glycol Cool Room Chiller Unit 4.5-12mm Fin space

Certificate:CE, ISO, and cetiifcate of producing special pressure equipment

Commercial Dual Discharge Glycol Cool Room Chiller Unit 4.5-12mm Fin space

11.Projects reference?

Commercial Dual Discharge Glycol Cool Room Chiller Unit 4.5-12mm Fin space

12.FAQ

1, Q:Where is your factory address?

A:We are factory and located in refrigeration equipment producing base Shengzhou,Zhejiang province.

2, Q: What is your package?

A: Our package comply to custom require not include original wood.

3, Q:What is your MOQ?

A: Ordinary products can order from 1 set.

4, Q: Can you offer sample?

A: Yes,we can offer sample.and cost and delivery at your charge.

5, Q:I can't find products on your list?

A: Please contact me directly.

6,Q:How can i confirm your factory?

A: We have third party verified document of Bureau Veritas report,you can download in company page or leave me message to get.

Send your message to this supplier
Send Now

Commercial Dual Discharge Glycol Cool Room Chiller Unit 4.5-12mm Fin space

Ask Latest Price
Brand Name :
Kaideli
Model Number :
ECG series
Certification :
CE,ISO9001-2008
Place of Origin :
China
MOQ :
1 Piece
Price :
$100.00 - $1,700.00/sets
Contact Supplier
Commercial Dual Discharge Glycol Cool Room Chiller Unit 4.5-12mm Fin space

ZHEJIANG KAIDI REFRIGERATION EQUIPMENT CO.,LTD

Verified Supplier
3 Years
zhejiang
Since 1995
Business Type :
Manufacturer
Total Annual :
120,000,000-150,000,000
Employee Number :
500~1000
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement