Color Haze Meter THC-100
The THC-100 color haze meter is designed with a full-spectrum LED light source and a spectral sensor. It is used to measure the haze, transmittance, color difference, platinum-cobalt chromaticity, yellowness, whiteness and other parameters of various transparent and translucent materials such as plastics, glass, and films, and can display the transmittance spectrum curve. The instrument uses a 7-inch touch screen design, which is simple and convenient to operate. The THC-100 color haze meter uses an open measurement area with two measurement states: horizontal and vertical. It can detect liquids and large-sized materials. The THC-100 color haze meter also uses a dual-caliber design of 21mm and 7mm, so small-sized materials can also be measured. The instrument is equipped with PC software to support data export and report printing.
Model | THC-100 |
Optical path structure | D/0 |
Wavelength range | 400-700nm |
Wavelength interval | 10nm |
Measuring aperture | 21mm , 7mm |
Measurement conditions |
Light source: CIE-A, CIE-C, CIE-D65 , A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CMF, U30, DLF, NBF, TL83, TL84 Observer angle: 2°, 10° |
Measuring time | Transmittance/haze: about 3s, other chromaticity indicators: 0.6s |
Measurement parameters |
Haze, total transmittance (T), spectral transmittance, CIE Lab, LCh, CIE Luv, XYZ, Yxy, Hunter Lab, MunsellMI, CMYK, whiteness WI (ASTM E313-00, ASTM E313-73,CIE/ISO,Hunter,Taube Berger Stensby),Yellowness YI(ASTM D1925,AST M E313-00, ASTM E313-73), Tint (ASTM E313-00), Metamerism Index Milm, APHA, Pt -Co (Platinum Cobalt Index), Gardner (Gardner Index), Color difference (△E*ab, △E*CH, △E*uv, △E*cmc (2:1), △E*cmc(1:1),△E*94,△E*00) |
Transmittance resolution | 0.01% |
Transmittance accuracy | Better than ±1% |
Transmittance repeatability | ≤0.03 (without preheating, standard deviation of 30 times of measuring a standard haze sheet with a haze of about 30 at 3s intervals) |
Haze resolution | 0.01% |
Haze accuracy | Better than ±1% |
Haze repeatability | ≤0.03 (without preheating, the standard deviation of 30 times of measuring the standard haze sheet with a haze of about 30 at an interval of 3s) |
Chromatic aberration repeatability | Standard deviation △E*ab, within 0.03 (measurement conditions: no preheating correction required, average value of 30 measurements of white glass at 3s intervals) |
Platinum-Cobalt Chroma Resolution | 0.01 |
Platinum-Cobalt Color Range | 0-500 |
Platinum-Cobalt Chromaticity Accuracy | ≤±(5%H+1), H is the standard value |
powered by | DC12V/3A |
Display | 7-inch touch screen, Android system |
System language | 14 languages |
Data Interface | USB(Type-B) |
Operating temperature range | 5~40℃, relative humidity 80% or lower (at 35℃), no condensation |
Storage temperature range | -20℃~45℃, relative humidity 80% or lower (at 35℃), no condensation |
Instrument dimensions | Length*width*height: 310mm*215mm*540mm |
Instrument weight | 5300g |