Heavy Duty Tension Load Cell Delicate Structure With Resistance To Partial Load Ability
RATED CAPACITY | DIMENSIONS | |||||||
A | B | C | D | E | F | G | H | |
10-25LB | 4.63 | 2.5 | 0.5 | 0.7 | 0.25 | 0.75 | 2.62 | 1/4-28UNF*0.50dp |
50-200LB | 4.63 | 2.5 | 0.75 | 0.95 | 0.25 | 0.75 | 2.62 | 1/4-28UNF*0.51dp |
Items | UNIT | TECHNICAL DATA |
Capacities | lb | 10,15,25,50,100,200 |
Rated output | mV/V | 2±10% |
Safe overload | FS | 150% |
Excitation voltage | V | 10-20 AC/DC |
Input resistance | OHMS | 385±10 |
Output resistance | OHMS | 350±3 |
Zero balance | FS | ±1.00% |
Seal type | FS | ENVIRONMENTALLY SEALED,POTTED,IP67 |
Non-linearity | FS | ±0.03% |
Hysteresis | FS | ±0.02% |
Repeatability | FS | ±0.02% |
Creep | FS | ±0.03% |
Compensated temperature range | ºC | -10 ~ +40 |
Temperature effect on zero | FS/ºC | ±0.02% |
Temperature effect on output | FS/ºC | ±0.001% |
Insulation resistance | MEGOHMS | >5000 |
Load cell cable | 4 conductor, 10 FT | |
Load cell wiring | Red +EXC Black -EXC Green +SIG White -SIG Braid/yellow: shield |