Specifications
Brand Name :
inntronic
Model Number :
IPW2C
Place of Origin :
China
MOQ :
1pc
Payment Terms :
L/C
Delivery Time :
15-30 days
Price :
Negotiable
pattern :
Single Point Load Cell
Capacity :
7.2kg to 72kg
output :
2mv/v
Material :
Aluminum load cell
application :
static weighing
interchangeable brand :
HBM
IP protection :
IP67
Accuracy grade :
C3
Non-linearity :
0.0166
Sensitivity :
130*25.4*31.4
Description
IPW2C 7.2kg to 72kg Single Point Load Cell for static weighing
Special features

− Accuracy class C3/C3MR and C6/C6MR with OIML-R60 test report
− Max. capacities: 7.2 kg ... 72 kg
− Off center load compensated(OIML R76)
− Degree of protection IP67(according to EN 60 529)
− Shielded connection cable
− optimized for dynamic weighing applications

Optional:

- Different accuracy classes with OIML-R60 test report
− Connection cable in six wire circuit
− Different cable lengths
− Aligned output, suitable for
− Aligned output, suitable for connectionin parallel

TypeIPW2C
Accuracy class1)C3; C3MR
Number of load cell intervals (nLC)3000
Maximum capacity (Emax)2))kg7.212183672

Minimum LC verification interval (vmin)
Accuracy class C3

g1251020

Temperature effect on
zero balance (TK0)
Accuracy class C3

% v.
Cn /
10 K

±0.0194±0.0233±0.0389±0.0389±0.0389

Minimum LC verification interval (vmin)
Accuracy class C3MR

g0.512510

Temperature effect on
zero balance (TK0)
Accuracy class C3MR

% v.
Cn /
10 K

±0.0097±0.0116±0.0155±0.00194±0.0194
Max. platform sizemm380 x 380
Sensitivity (Cn)mV/V2.2±0.2
Zero balance0±0.12

Temperature effect on
sensitivity (TKC)3)
Temperature range
+20 ... +40℃ [+68 ... +104℉]
−10 ... +20℃ [+14 ... +68℉]

% v.
Cn /
10 K

±0.0175
±0.0117

Hysteresis error (dhy)3)% of Cn±0.0166
Non-linearity (dlin)3)±0.0166
Minimum dead load output return (DR)±0.0166
Off center load error4)±0.0233
Input resistance (RLC)Ω300 ... 500
Output resistance (R0)300 ... 500
Reference excitation voltage (Uref)V5
Nominal range of excitation voltage (BU)1 ... 12
Insulation resistance (Ris) at 100 VDC> 2
Nominal temp. range (BT)

°C
[°F]

−10 ... +40 [+14 ... +104]
Service temp. range (Btu)−10 ... +50 [+14 ... +122]
Storage temp. range (Btl)−25 ... +70 [−13 ... +158]

Safe load limit (EL ), at max.
100mm eccentricity

% of
Emax

150
160

Lateral load limit (Elq), static

% of
Emax

300
Breaking load (Ed)300
Weight (G), approx.kg0.25

Protection class according to
EN 60 529 (IEC 529)

IP67

Material: Measuring element
Coating
Cable sheath

Aluminum
Silicone rubber
PVC

Load Cell IPW2C 72kg C3 Single Point weighing Load Cell force sensor Aluminium weight sensor For Static Weighing 2mv/vLoad Cell IPW2C 72kg C3 Single Point weighing Load Cell force sensor Aluminium weight sensor For Static Weighing 2mv/v

Load Cell IPW2C 72kg C3 Single Point weighing Load Cell force sensor Aluminium weight sensor For Static Weighing 2mv/v
Load Cell IPW2C 72kg C3 Single Point weighing Load Cell force sensor Aluminium weight sensor For Static Weighing 2mv/v

Send your message to this supplier
Send Now

Load Cell IPW2C 72kg C3 Single Point weighing Load Cell force sensor Aluminium weight sensor For Static Weighing 2mv/v

Ask Latest Price
Brand Name :
inntronic
Model Number :
IPW2C
Place of Origin :
China
MOQ :
1pc
Payment Terms :
L/C
Delivery Time :
15-30 days
Contact Supplier
Load Cell IPW2C 72kg C3 Single Point weighing Load Cell force sensor Aluminium weight sensor For Static Weighing 2mv/v

Innovation Electronic Co.,Ltd

Site Member
8 Years
zhejiang, hangzhou
Since 2012
Business Type :
Manufacturer, Distributor/Wholesaler, Agent, Importer, Exporter, Trading Company, Seller
Total Annual :
1500000-2000000
Certification Level :
Site Member
Contact Supplier
Submit Requirement