40kg Counting Scale Portable Load Cell Sensor For Weight Measurement ODM
-- Accuracy class C3 with OIML-R60 test report
-- Off center load compensated (OIML R 76)
-- Max. capacities: 3 kg ... 40 kg
-- Degree of protection IP67(according to EN 60 529)
-- Shielded connection cable
-- Optimized for static weighing applications
-- Accuracy class C6 with OIML-R60 test report
-- Connection cable in six wire circuit
-- Different cable lengths
− Aligned output, suitable for connectionin parallel
Type | IPW6C | ||||||||
Accuracy class1) | C3; C3MR | ||||||||
Number of load cell intervals (nLC) | 3000 | ||||||||
Maximum capacity (Emax)2)) | kg | 3 | 5 | 10 | 15 | 20 | 30- | 40 | |
Minimum LC verification interval (vmin) Accuracy class C3 | g | 10 | 10 | 20 | 20 | 50 | 50 | 50 | |
Temperature effect on zero balance (TK0) Accuracy class C3
| % v. Cn / 10 K
| ±0.0233 | ±0.0280 | ±0.0280 | ±0.0186 | ±0.0350 | ±0.0233 | ±0.0350 | |
Minimum LC verification interval (vmin) Accuracy class C3MR | g | 0.2 | 0.5 | 1 | 1 | 2 | 2 | 5 | |
Temperature effect on zero balance (TK0) Accuracy class C3MR | % v. Cn / 10 K
| ±0.0093 | ±0.0140 | ±0.0140 | ±0.0093 | ±0.0140 | ±0.0093 | ±0.0175 | |
Max. platform size | mm | 300 x 300 | |||||||
Sensitivity (Cn) | mV/V | 2.0±0.2 | |||||||
Zero balance | 0±0.12 | ||||||||
Temperature effect on sensitivity (TKC)3) Temperature range +20 ... +40℃ [+68 ... +104℉] −10 ... +20℃ [+14 ... +68℉] | % v. Cn / 10 K
| ±0.0175 ±0.0117 | |||||||
Hysteresis error (dhy)3) | % of Cn | ±0.0166 | |||||||
Non-linearity (dlin)3) | ±0.0166 | ||||||||
Minimum dead load output return (DR) | ±0.0245 | ||||||||
Off center load error4) | ±0.0233 | ||||||||
Input resistance (RLC) | Ω | 300 ... 500 | |||||||
Output resistance (R0) | 300 ... 500 | ||||||||
Reference excitation voltage (Uref) | V | 5 | |||||||
Nominal range of excitation voltage (BU) | 1...12 | ||||||||
Insulation resistance (Ris) at 100 VDC | GΩ | > 2 | |||||||
Nominal temp. range (BT) | °C [°F] | −10 ... +40 [+14 ... +104] | |||||||
Service temp. range (Btu) | −10 ... +50 [+14 ... +122] | ||||||||
Storage temp. range (Btl) | −25 ... +70 [−13 ... +158] | ||||||||
Safe load limit (EL ), at max. 100mm eccentricity | % of Emax | 150 100 | |||||||
Lateral load limit (Elq), static | % of Emax | 300 | |||||||
Breaking load (Ed) | 300 | ||||||||
Deflection at Emax (snom), approx. | mm | < 0.5 | |||||||
Weight (G), approx. | kg | 0.25 | |||||||
Protection class according to EN 60 529 (IEC 529) | IP67 | ||||||||
Material: Measuring element Coating Cable sheath | Aluminum Silicone rubber PVC |