Radiators Host Machine Air Source Heat Pump Ultra-low Temperature Type
Quick Details
Model data
Model | SLNA-017Ycode name.pdf | |||
Compressor capacity | 6HP | |||
Function | Heating and Cooling | |||
Electricity | 380V-3N-50Hz | |||
Working conditions | ℃ | -25~~+45 | ||
Data | Heata | Nominal capacity | KW | 12 |
Input power | KW | 4.55 | ||
COP | / | 2.4 | ||
Heating IPLV(H) | 2.7 | |||
Coolb | Nominal capacity | KW | 14 | |
Input power | KW | 5 | ||
COP | / | 2.5 | ||
Cooling IPLV(C) | 2.7 | |||
A7W35c | KW/COP | 19.5/4.21 | ||
A2W35 | KW/COP | 27/3.60 | ||
A-7W35 | KW/COP | 21.5/2.8 | ||
A-15W55 | KW/COP | 19.7 /1.94 | ||
A-20W45 | KW/COP | 18.1/2.02 | ||
Max. running currency | A | 25 | ||
Compressor quantity | set | 2 | ||
Refrigerant/charging quantity kg | / | R22/4.8 | ||
Air blow type | / | Side | ||
Water pipe diameter | mm | G1.2〞 | ||
Rating flow | m³/h | 3.2 | ||
Water side pressure loss | kPa | ≤45 | ||
Noise level | dB(A) | 62 | ||
Overall dimensions(L×W×H) | mm | 1120×440×1360 | ||
Weight | kg | 130 |
a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal heating capacity
b:Nominal refrigeration conditions: ambient dry bulb temperature 35℃, outlet water temperature 7℃, water flow 0.172 * nominal cooling capacity
c:A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃
Yushen Products Advantages
Applications
House, Villas' air conditioning, hot water supply;office buildings' air conditioning ;hotels and restaurants
About air source heat pump
1) The air source heat pump system is a combination of cold and heat sources. There is no need to set up a special freezer room or boiler room. The unit can be placed on the roof or the ground at will, without occupying the effective use area of the building. The construction and installation is very simple.
(2) The air source heat pump system has no cooling water system, no cooling water consumption, and no power consumption of the cooling water system. From the perspective of safety and hygiene, considering air source heat pumps also has obvious advantages.
(3) Because the boiler is not needed, the corresponding boiler fuel supply system, dust removal system and flue gas emission system are not needed, the system is safe and reliable, and has no pollution to the environment.
(4) The cold (hot) water unit adopts modular design. It does not need to set up a standby unit. During the operation, the computer automatically controls and adjusts the running status of the unit to make the output power adapt to the working environment.