17KW High COP Air Energy Heat Pump Air to Water Equipment SDWA-017Y
Brief Introduction
Nominal heating conditions:
Model Parameter
Model | SDWA-017Ycode name.pdf | |||
Compressor capacity | 6HP | |||
Function | Hot water | |||
Electricity | 380V 3N-50Hz | |||
Working conditions | ℃ | -25~+43 | ||
Nominal heating capacity | KW | 17 | ||
COP | KW/KW | 4.1 | ||
Nominal input power | KW | 4.14 | ||
Max. running currency | A | 11.5 | ||
Highest water temperature | ℃ | 60 | ||
Compressor quantity | Set | 1 | ||
Refrigerant/charging quantity kg | / | R22/4.8 | ||
Air blow type | / | Top | ||
Water pipe diameter | / | 1 1/2'' | ||
Rating flow | m³/h | 3 | ||
Water side pressure loss | kPa | ≤45 | ||
Noise level | dB(A) | 62 | ||
Overall dimensions(L×W×H) | mm | 860×820×1080 | ||
Weight | kg | 197 |
Application
Any places need hot water:
Home bathroom, public bathroom, swimming pool, factory production line, domitory etc.
Yushen Products Advantages
Main technology
Ultra-low temperature air energy operation technology, air source heat pump manufacturers have their own ultra-low temperature technology, and now most of the domestic ultra-low temperature operation technology of air energy manufacturers is imported from Germany. On this basis, the development of ultra-fast defrosting technology. Since the air energy heat pump main unit is generally installed outdoors, frosting may occur in frequent rain and snow. The air source heat pump main unit can intelligently judge the demand for defrosting, a very short defrosting time of 90 seconds, and this defrosting time is only one-sixth of the products of other industries.
2. Turbine direct injection and enthalpy technology, which is called jet blasting technology in the industry. Because the heating efficiency of the air energy heat pump in extreme cold weather will be greatly attenuated, resulting in unsatisfactory heating effect. At this point, the ultra-low temperature air source heat pump needs to use the jet boosting technology to create a two suction port in the scroll, through the first The second suction circuit increases the refrigerant flow and the difference of the main circulating refrigerant, greatly improves the refrigerant circulation system, makes full use of the refrigerant flow and utilization rate in the compressor, and improves the stability and heating efficiency of the system. The ultra-low temperature air source heat pump is the first to break the dilemma that the air energy heat pump can not operate efficiently in the north. The 46,000-square Langfang air energy heating project provides reference and guidance for the peers.