Specifications
Brand Name :
Yushen
Model Number :
SLNA-007U/009U(P) SLNA-007UVP , SLNA(B)-014UP
Certification :
CCC, ISO, CQC
Place of Origin :
China
MOQ :
1 set
Price :
negotiable
Payment Terms :
T/T
Supply Ability :
10 sets/day
Delivery Time :
1-2weeks
Packaging Details :
Reinforced Carton box with wooden tray
Key word :
Home Air Source Heat Pump
Control :
automatic
Function :
both Cooling and heating
Refrigerant :
Freon R404a and other
Suitable working conditions :
-25C~+45C
Electricity :
220V-3N-50hz
Description

Compact Size Ultra-low Temperature Air Source Heat Pump No Pollution Water Heater

Key features

Environmentally friendly products

no pollution, no burning emissions, will not cause harm to the human body, and have good social benefits. The utility model has stable performance, is not affected by the environment, and the product runs all the year round, and is not affected by bad weather such as nighttime, cloudy weather, rain and snow, and can realize hot water 24 hours a day, 365 days a year. The utility model has good safety performance, no hidden danger, heat exchange with water by indirect heating method, no leakage, air leakage, etc., and is hidden in electric water and gas water heaters.

Convenience

The air energy heat pump occupies a small space and has a similar shape. The air conditioner outdoor unit can be directly connected or connected to the insulated water tank heating tube. It is suitable for high-rise buildings and large-scale central heating in large and medium-sized cities. It is the best choice. . No solar panels are needed, the area is reduced by 95%, and the area is 50%. Solar water heaters can be used to reduce solar collectors, save a large amount of solar collectors, and reduce the volume of hot water storage tanks.

Yushen Products Advantages

1. Jet Booster compressors, no decay in heating in low environmental temperature

2. Yushen ASHP could work in untra low temeprature cold climate -25C

3. More than 6 million M2 heating area project cases all over the different latitude area.

4.Automatic testing line,100% finished products testing

5. long heating time and less defrosting time,35% more powerful than other products

Select models

code name.pdf

Model SLNA-007UM SLNA(B)-009U(P) SLNA(B)-014U(P)
Compressor capacity 2HP 3HP 5HP
Function Heating and Cooling Heating and Cooling Heating and Cooling
Electricity 220V-1N-50Hz 220V-1N-50Hz 220V-1N-50Hz
Working conditions -25~~+45 -25~~+45 -25~~+45
Data Heata Nominal capacity KW 3.9 5.8 9.2
Input power KW 1.69 2.52 3.96
COP / 2.3 2.3 2.3
Heating IPLV(H) 2.53 2.53 2.6
Coolb Nominal capacity KW 4.4 6.5 11.0
Input power KW 1.69 2.6 4.31
COP / 2.6 2.5 2.55
Cooling IPLV(C) 2.7 2.7 2.75
A7W35c KW/COP 6.4/4.1 9.2/4.10 14.0/4.1
A2W35 KW/COP 5.8/3.6 8.0/3.6 11.2/3.60
A-7W35 KW/COP 4.3/2.7 5.9/2.7 9.5/3.0
A-15W55 KW/COP 3.4/1.9 5.0/1.90 8.4 /1.94
A-20W45 KW/COP 2.9/1.94 4.5/1.95 7.7/2.00
Max. running currency A 13.2 18 30
Compressor quantity set 1 1 1
Refrigerant/charging quantity kg / R404A/2.2 R404A/2.2 R22/4.50
Air blow type / Side Side Side
Water pipe diameter inch G1〞 G1〞 G1.2〞
Rating flow m³/h 1.6 1.6 2.5
Water side pressure loss kPa ≤35 ≤35 ≤35
Noise level dB(A) 59 59 61
Overall dimensions(L×W×H) mm 1087×435×901 1087×435×901 1120×440×1360
Weight kg 70 70 130

a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal heating capacity

b:Nominal refrigeration conditions: ambient dry bulb temperature 35℃, outlet water temperature 7℃, water flow 0.172 * nominal cooling capacity

c:A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃

Application

Air source heat pump heating and cooling units could heat and refriegration.They could be matched with underfloor coil, fan coils,radiators etc. widely used in new-built or energy-saving transformation buildings, such as appartments,villas, mini hotels, tec.

How air source heat pump energy saving

Equipment Air Source Heat Pump Electric boiler Gas boiler Oil boiler
Energy heating value 860Kcal/kwh 860Kcal/kwh 8000Kcal/M3 10300Kcal/L
Annual COP >=400% <=90% <=75% <=75%
Heating results 860*400%=3440Kcal/kwh 860*90%=774kcal/kwh 800*75%=6000kcal/M3 10300*75%=7725kcal/L
Making 1M3 hot water need 1000/3440=14.5Kwh 1000/774=64.6kwh 1000/6000=8.3kwh 1000/7725=6.47L
Unit price of energy USD 0.15/kwh USD 0.15/kwh USD1/m3 USD 1.1/L
Price 2.175 9.69 8.3 7.117

Send your message to this supplier
Send Now

Compact Size Ultra Low Temperature Heat Pump No Pollution Water Heater

Ask Latest Price
Brand Name :
Yushen
Model Number :
SLNA-007U/009U(P) SLNA-007UVP , SLNA(B)-014UP
Certification :
CCC, ISO, CQC
Place of Origin :
China
MOQ :
1 set
Price :
negotiable
Contact Supplier
Compact Size Ultra Low Temperature Heat Pump No Pollution Water Heater

Shandong Yushen Energy Technology Co., Ltd.

Active Member
7 Years
shanghai, shanghai
Since 2014
Business Type :
Manufacturer
Total Annual :
7000000-12000000
Certification Level :
Active Member
Contact Supplier
Submit Requirement