High Temperature Heat Pump To Heat House 2HP~3HP Power Saving
Brief Introduction
1.More convinent.
Compared to conventional AC unit, Air source heat pump could conected to more indoor devices such as underfloor heating coil, radiator.No need to change indoor facilities if you want to change the AC
2. Significantly energy saving
ASHP use less than 30% electricity,more than 70% energy are absorb from the air, it saves the bills.
3.Easy to install
The unit can be installed outdoors, such as in open spaces such as roofs and floors. It has a small footprint and is easy to install. It does not need to be equipped with a machine room to save space.
Comparasion to Electric AC unit
Items | Air source heat pump | Air conditioner unit |
When heating | 40% energy saving than Ac | --- |
When cooling | Equal energy consumption | Equal |
Installation | Easy | easy |
Maintenance | Little | some |
Suitable for Ender | AC fans, under floor,radiator | AC fans only |
Extra | Hot water | no |
Yushen Products Advantages
Model data/ Parameter
Model | SLNA-007UMcode name.pdf | |||
Compressor capacity | 2HP | |||
Function | Heating and Cooling | |||
Electricity | 220V-1N-50Hz | |||
Working conditions | ℃ | -25~~+45 | ||
Data | Heata | Nominal capacity | KW | 3.9 |
Input power | KW | 1.69 | ||
COP | / | 2.3 | ||
Heating IPLV(H) | 2.53 | |||
Coolb | Nominal capacity | KW | 4.4 | |
Input power | KW | 1.69 | ||
COP | / | 2.6 | ||
Cooling IPLV(C) | 2.7 | |||
A7W35c | KW/COP | 6.4/4.1 | ||
A2W35 | KW/COP | 5.8/3.6 | ||
A-7W35 | KW/COP | 4.3/2.7 | ||
A-15W55 | KW/COP | 3.4/1.9 | ||
A-20W45 | KW/COP | 2.9/1.94 | ||
Max. running currency | A | 13.2 | ||
Compressor quantity | set | 1 | ||
Refrigerant/charging quantity kg | / | R404A/2.2 | ||
Air blow type | / | Side | ||
Water pipe diameter | inch | G1〞 | ||
Rating flow | m³/h | 1.6 | ||
Water side pressure loss | kPa | ≤35 | ||
Noise level | dB(A) | 59 | ||
Overall dimensions(L×W×H) | mm | 1087×435×901 | ||
Weight | kg | 70 |
a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal
b:Nominal refrigeration conditions: ambient dry bulb temperature 35℃, outlet water temperature 7℃, water flow 0.172 * nominal cooling capacity
c:A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃