Multi Functional Commercial Air Source Heat Pump Long Heating Time 62 DBA
Commercial Air Source Heat Pump Introduction
The biggest advantage of Commercial Air Source Heat Pump (ASHP) is energy saving. Generally 40% energy-saving than convnetional AC in heating.
An ASHP uses a refrigerant system involving compressors and condensers to absorb heat at one place and release it at another.
Commercial Air Source Heat Pump can be used as a space heater or cooler, and are sometimes called "reverse-cycle air conditioners".
In domestic heating use, an ASHP absorbs heat from outside air and releases it inside the building, as hot air, hot water-filled radiators, underfloor heating and/or domestic hot water supply.
Commercial Air Source Heat Pump Applications
Heating and cooling for all kinds of buildings such as office building, hotel and residential community.
It could connected with all kinds of indoor deveices, fan coil, radiators, floor coils.
This series standard models
Model | SLNA-017Y | SLNA-032Y | SLNB-035Y | SLNB-047Y | SLNC-075Y | |||
Compressor capacity | 6HP | 10HP | 12.5HP | 15HP | 25HP | |||
Function | Heating and Cooling | Heating and Cooling | Heating and Cooling | Heating and Cooling | Heating and Cooling | |||
Electricity | 380V-3N-50Hz | 380V-3N-50Hz | 380V-3N-50Hz | 380V-3N-50Hz | 380V-3N-50Hz | |||
Working conditions | ℃ | -25~~+45 | -25~+45 | -25~+45 | -25~+45 | -25~+45 | ||
Data | Heata | Nominal capacity | KW | 12 | 21.5 | 22.3 | 28.1 | 44.5 |
Input power | KW | 4.55 | 9.1 | 9.4 | 11.7 | 18.3 | ||
COP | / | 2.4 | 2.3 | 2.35 | 2.4 | 2.4 | ||
Heating IPLV(H) | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 | |||
Coolb | Nominal capacity | KW | 14 | 25 | 28 | 39 | 62 | |
Input power | KW | 5 | 10 | 10.4 | 13.1 | 20.7 | ||
COP | / | 2.5 | 2.5 | 2.7 | 2.9 | 3 | ||
Cooling IPLV(C) | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 | |||
A7W35c | KW/COP | 19.5/4.21 | 32.0/4.1 | 35.0/4.1 | 47.0/4.1 | 75.0/4.2 | ||
A2W35 | KW/COP | 27/3.60 | 27/3.60 | 28.5/3.60 | 39.5/3.20 | 62.5/3.20 | ||
A-7W35 | KW/COP | 21.5/2.8 | 21.5/2.8 | 23.5/2.9 | 32/2.9 | 50/2.9 | ||
A-15W55 | KW/COP | 19.7 /1.94 | 19.7 /1.94 | 20.2 /1.94 | 28.1/1.94 | 45.5 /1.97 | ||
A-20W45 | KW/COP | 18.1/2.02 | 18.1/2.02 | 18.7/2.02 | 23.6/2.03 | 37.4/2.04 | ||
Max. running currency | A | 25 | 25 | 27 | 35 | 56 | ||
Compressor quantity | set | 2 | 2 | 1 | 2 | 2 | ||
Refrigerant/charging quantity kg | / | R22/4.8 | R22/3.7*2 | R22/9 | R22/10 | R22/15*2 | ||
Air blow type | / | Side | Top | Side | Top | Top | ||
Water pipe diameter | mm | G1.2〞 | 32 | 32 | 50 | 50 | ||
Rating flow | m³/h | 3.2 | 5.5 | 5.9 | 8.3 | 12.6 | ||
Water side pressure loss | kPa | ≤45 | ≤45 | ≤45 | ≤45 | ≤45 | ||
Noise level | dB(A) | 62 | 62 | 62 | 62 | 62 | ||
Overall dimensions(L×W×H) | mm | 1120×440×1360 | 1530×750×1370 | 1490×900×1900 | 1450×1100×2080 | 2100×1100×2080 | ||
Weight | kg | 130 | 320 | 350 | 470 | 730 |
a:Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal heating capacity. | ||||||||
b:Nominal refrigeration conditions: ambient dry bulb temperature 35℃, outlet water temperature 7℃, water flow 0.172 * nominal cooling capacity | ||||||||
c:A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃ |
A: We are manufacturer factory. Our factory is located in Shandong province with an area of 530,000 sq meters .
Q: Do you provide OEM service
A: yes,with OEM service provided, MOQ> 20 Units.
QHow long is your heat pump delivery ?
A: production time generally it is 1-5 working days if the goods are in stock.
or it is 15-25 working days if the goods are not in stock, it is according to quantity.
Delivery also depends on sea shipment to your country.
Company Service