4CE-9Y (9HP) Medium and low Temperature Water-Cooled Refrigertion Condensing Unit,Water-Cold Chiller Condensing Unit
The compression condensing unit adopts shell-and-tube water-cooling condensers, the heat transfer tubes are high-efficiency and dense-ribbed copper tubes, the tube boxes at both ends can be disassembled and replaced when necessary, so as to facilitate the connection of the cooling water tubes, the unit can be matched with the chocolate industry, ice cream industry, etc. .
Stable performance, high efficiency and energy saving. COMPRESSOR FEATURES: With a durable valve design, high-quality wear-resistant bearing components and easy maintenance, use and speed control, smooth operation, and equipped with efficient, suction cooling motor.
Features:
1. low noise water cooled units energy regulation and start off unloading; built in check valves and safety valves; light weight, low vibration, low noise, small footprint.
2. low noise water cooled unit motor protection device phase sequence, missing and start-up Delay Protection;
3. low noise water cooled unit exhaust temperature, oil flow oil pressure protection for R22, R134a, R404a, R507 refrigerant;
4. low noise water cooled Unit each unit factory standard with computer controller, automatically adjust the running time of the compressor, extend the life of the compressor;
5. low noise water cooled unit is mainly used in places where the temperature requirement is-5 °c ~-20 °C, such as: food processing and storage, fruit and vegetable processing and fresh keeping, chemical industry, pharmaceutical industry, process ice water, air conditioning, etc. .
6. low noise water cooled units are widely used in fresh storage, cold storage, controlled atmosphere storage, low temperature workshop, process ice water and other places.
Specifications:
Based on -15℃ evaporating temperature and 18℃ suction temperature and 0℃ K subcooling for the liquid refrigerant.
Temperature range | Model (R404) | Horse Power | Applicable coldroom |
High temp | 2HES-2Y | 2HP | Chiller room |
High temp | 2GES-2Y | 2HP | Chiller room |
High temp | 2FES-3Y | 3HP | Chiller room |
High temp | 2EES-3Y | 3HP | Chiller room |
High temp | 2DES-3Y | 3HP | Chiller room |
High temp | 2CES-4Y | 4HP | Chiller room |
High temp | 4FES-5Y | 5HP | Chiller room |
High temp | 4EES-6Y | 6HP | Chiller room |
High temp | 4DES-7Y | 7HP | Chiller room |
High temp | 4CES-9Y | 9HP | Chiller room |
High temp | 4VES-10Y | 10HP | Chiller room |
High temp | 4TES-12Y | 12HP | Chiller room |
High temp | 4PES-15Y | 15HP | Chiller room |
High temp | 4NES-20Y | 20HP | Chiller room |
High temp | 4HE-25Y | 25HP | Chiller room |
High temp | 4GE-30Y | 30HP | Chiller room |
High temp | 6HE-35Y | 35HP | Chiller room |
Low temp | 2FES-2Y | 2HP | Freezer room |
Low temp | 2EES-2Y | 2HP | Freezer room |
Low temp | 2DES-2Y | 2HP | Freezer room |
Low temp | 2CES-3Y | 3HP | Freezer room |
Low temp | 4FES-3Y | 3HP | Freezer room |
Low temp | 4EES-4Y | 4HP | Freezer room |
Low temp | 4DES-5Y | 5HP | Freezer room |
Low temp | 4CES-6Y | 6HP | Freezer room |
Low temp | 4TES-9Y | 9HP | Freezer room |
Low temp | 4PES-12Y | 12HP | Freezer room |
Low temp | 4NES-14Y | 14HP | Freezer room |
Low temp | 4HE-18Y | 18HP | Freezer room |
Low temp | 4GE-23Y | 23HP | Freezer room |
Low temp | 6HE-28Y | 28HP | Freezer room |
Low temp | 6GE-34Y | 34HP | Freezer room |
Low temp | 6FE-44Y | 44HP | Freezer room |
Packing: each unit with a separate plywood wooden case.