Specifications
Brand Name :
TIANAN
Model Number :
ZGS-Z. G-/35
Certification :
ISO9001-2000, ISO9001, CCC
Place of Origin :
CHINA
MOQ :
1unit
Price :
Pending
Payment Terms :
L/C, T/T, D/P, D/A
Supply Ability :
2000Sets/Year
Delivery Time :
45 work days
Packaging Details :
Nude
Cooling Method :
Oil-immersed Type Transformer
Rated voltage :
36KV
Mechanical endurance :
>2000
Rated Capacity :
630KVA~1600KVA
Phase :
Three
Rated voltage of LV :
0.27kV, 0.3kV, 0.315kV, 0.4kV
Connecting symbol :
Dyn11 or Yyn0
HV tapping range :
+5% or + 2x2.5%
Description

36kV Combined Transformer for Photovoltaic power generation

Product Description:

Summarize:
ZGS-Z.F-/36 series wind power combined transformer is a special power equipment integrating step-up transformer, HV current limited fuse, load switch, LV switch and related auxiliary equipments. It transforms the 0.69kV voltage produced by wind power motor into 35kV,and output the electricity through 35KV cable circuit, which is the ideal equipment in wind power complete set equipment.

Normal ambient conditions for service:
1. Altitude shall be within 2000m
2. Ambient temperature range shall be : -40ºC~+40ºC
3. Outdoor wind speed shall not exceeds 35m/s
4. Relative humidity: daily average value shall not exceed 95%, monthly average value 90%
5. Installation site: indoor
6. Service environment: installed in sites with no fire or explosion danger, serious fifth, chemical corrosion and fierce vibration.
7. When transcend the above normal ambient conditions for service, users can negotiate with us to solve.


Product technical parameter
Parameter of 35kV oil immersed load switch
Table 1
S/N Name Unit Parameter
1 Rated voltage KV 40.5
2 Rated current A 315 630
3 Rated frequency Hz 50
4 Rated short-circuit withstand current kA/2s 12.5 20
5 Rated peak withstand current kA 31.5 50
6 Mechanical endurance times >2000
7 1 min power withstand voltage (phase-to-phase, phase-to-earth) kV 95
8 Lightning impulse level (phase-to-phase, phase-to-earth) KV 185

Parameter of 35kV fuse
Table 2
Rated voltage Fuse rated current A Fusing element rated current A Rated Max. breaking current kA
40.5 40 20,25,31.5,40,50,63 31.5

Parameter of lightning arrester
Table 3
Rated voltage Continuous operating voltage DC reference voltage (1mA) Nominal discharging current Nominal discharging current residual 2ms square-wave current withstand value

51kV
40.8kV ≥73kV 5kA(peak value) ≤134kV (peak value) ≥250A(peak value)

Condensation controller and other auxiliary equipment can be added in the body as per clients' requests.
Note: As per different requirement from client, the capacity of transformer can be customized.
Send your message to this supplier
Send Now

36kV Compact Transformer Substation For Photovoltaic Power Generation

Ask Latest Price
Brand Name :
TIANAN
Model Number :
ZGS-Z. G-/35
Certification :
ISO9001-2000, ISO9001, CCC
Place of Origin :
CHINA
MOQ :
1unit
Price :
Pending
Contact Supplier
36kV Compact Transformer Substation For Photovoltaic Power Generation

Ningbo Tianan (Group) Co.,Ltd.

Verified Supplier
8 Years
zhejiang, ningbo
Since 1969
Business Type :
Manufacturer, Exporter, Trading Company, Seller
Total Annual :
250000000-300000000
Employee Number :
3000~3500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement