Specifications
Brand Name :
Tianan Electric
Model Number :
CZBT1-132
Certification :
IEC
Place of Origin :
CHINA
MOQ :
1 unit
Price :
Pending
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
10000 units/year
Delivery Time :
45 days
Packaging Details :
Wooden Carton
Frequency :
50Hz
Special Conditions :
Depends on The Customer
System Voltage :
132KV 145Kv
Capacity :
16000KVA
Sound level :
≤65 dB
Protection accuracy :
5P20
Description

Promotional Various Durable Using Power Transformer Mobile Compact Substation

* Carefully Selected Materials
The shell is made of stainless steel, aluminum alloy, cold-rolled plate, color steel plate, tiled, wooden strip, etc., and has good insulation, sealing and excellent heat resistance.

* With Major Brands
Effective control and protection system, fast installation and operation, superior performance.

* High Quality
The internal wiring is neatly arranged, the loss is low, and the heat dissipation performance is strong, which can be used in different environments.

* Long Service Life Of Equipment
The use of automated equipment to ensure accurate product size, production and production in strict accordance with international standards, maintenance-free during the period, the quality is more guaranteed.

Service condition

1 Ambient condition

a. Altitude ≤ 1000m;

b. Ambient temperature

Range of temperature: -25℃~+40℃;

c. Wind speed (outdoor) ≤ 35m/s;

d. Relative humidity ≤ 90%(+25℃);

e. Installation spot

The place shall have no fire, explosion, chemical corrosion and exquisite vibration.

2 Move condition of the substation

a. Max. speed ≤ 30km/h,when road surface is flat;

b. Max. speed ≤ 10km/h, when road surface is not flat.

Note: If the above condition can’t satisfy requirements, customer can consult with manufacturer to resolve it.

Table1

No. Item Unit Parameter
1 System voltage kV 132
2 Rated voltage kV 145
3 Rated frequency Hz 50
4 Rated current A 2000 ,1600
5 Rated 1min power frequency withstand voltage kV 275
6 Rated lightning impulse withstand voltage kV 650
7 Rated short time withstand current KA 25,31.5,40
8 Rated short time withstand time s 3
9 Rated peak withstand current kA 63,80,100

Table 2 Rated technical parameter of circuit breaker

No. Item Unit Parameter
1 System voltage kV 132
2 Rated voltage kV 145
3 Rated frequency Hz 50
4 Rated current A 2000
5 Rated 1min power frequency withstand voltage kV 275
6 Rated lightning impulse withstand voltage kV 650
7 Rated short time withstand current / time KA/s 40/4
8 Rated peak withstand current kA 100
9 Rated short circuit breaking current kA 40
10 Rated short circuit making current kA 100
11 DC component % 40
12 Rated operation sequence O 0.3s CO 180s CO
13 Opening time ms 35±5
14 Closing time ms 105±15
15 Breaking time ms ≤60
16 Non-simultaneity between poles Closing ms ≤5
Opening ms ≤3
17 Fracture no. of each pole 1
18 Mechanical endurance Times ≥6000
19 Full capacity continuous breaking times Times ≥20
20

SF6 gas pressure

(20℃)

Rated value MPa 0.60
Alarm value MPa 0.55
Locking value MPa 0.50
21

SF6 gas moisture

content(μl/l)

Acceptance value PPm ≤150
Operation allowable value PPm ≤300
22 SF6 yearly gas leakage rate % ≤0.5
23 Total weight of each circuit breaker kg 2000

Table3 table4 Parameters of current transformer

Rated primary current 150,300,500,750,1000,1500,2000
Rated secondary current 5A

Rated output capacity and accuracy level

See table 4

Current ratio Rated output capacity VA Measure accuracy level Protection accuracy level

150/5

300/5

500/5

750/5

1000/5

1500/5

2000/5

20

20

30

30,40

40,50

50

50

0.5

0.5

0.5

0.5

0.5

0.5

0.5

5P20

5P20

5P20

5P20

5P20

5P20

5P20

Note: (1) Straight-through type bushing current transformer is attached in the circuit breaker.

Table5 Parameters of lightning arrester

No. Item Unit Parameter
1 System voltage kV 132
2 Rated voltage kV 150
3 Rated frequency Hz 50
4 Nominal discharge current kA 10
5 DC 1mA reference voltage kV ≥245
6 Residual voltage under lightning impulse current (peak) kV ≤435
7 Residual voltage under operation impulse current (peak) kV ≤370
22 Residual voltage under steep wave impulse current (peak) kV ≤490

Table 6 Parameters of neutral point lightning arrester

No. Item Unit Parameter
1 System voltage kV 132
2 Rated voltage kV 90
3 Rated frequency Hz 50
4 Nominal discharge current kA 1.5
5 DC 1mA reference voltage kV ≥140
6 Residual voltage under lightning impulse current (peak) kV ≤260
7 Residual voltage under operation impulse current (peak) kV ≤240
8 Residual voltage under steep wave impulse current (peak) kV /

Table7 Technical parameters of switch equipment on LV side

No. Item Unit Parameter
1 System voltage kV 11.5
2 Rated voltage kV 12
3 Rated frequency Hz 50
4 Rated current A 2000,1600,1250,
5 Rated 1min power frequency withstand voltage kV 42/48
6 Rated lightning impulse withstand voltage kV 75/85
7 Rated short time withstand current kA 40,31.5,25
8 Rated short time withstand time s 4
9 Rated peak withstand current kA 100,80,63
10 Rated short circuit breaking current kA 40,31.5,25
11 Rated short circuit making current kA 100,80,63
12 Rated operation sequence O 0.3s CO 180s CO
13 Mechanical endurance Times ≥10000

Promotional Various Durable Transformer Mobile Electrical Substation Transformer

Send your message to this supplier
Send Now

Promotional Various Durable Transformer Mobile Electrical Substation Transformer

Ask Latest Price
Brand Name :
Tianan Electric
Model Number :
CZBT1-132
Certification :
IEC
Place of Origin :
CHINA
MOQ :
1 unit
Price :
Pending
Contact Supplier
Promotional Various Durable Transformer Mobile Electrical Substation Transformer
Promotional Various Durable Transformer Mobile Electrical Substation Transformer

Ningbo Tianan (Group) Co.,Ltd.

Verified Supplier
8 Years
zhejiang, ningbo
Since 1969
Business Type :
Manufacturer, Exporter, Trading Company, Seller
Total Annual :
250000000-300000000
Employee Number :
3000~3500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement