Control Panel Screw Air Compressor Spare Parts 1900071011
Air compressor controller instruction:
After power on, the controller is in the stop state, the stop light is on, showing the exhaust temperature value.The displayed exhaust temperature value is the actual measured exhaust temperature value plus the exhaust temperature modification value.The temperature modification is used to make up for the deviation between the actual measured temperature and the actual temperature.
The Settings:
1.Instructions for setting the state:
When you hold down the "Esc" key for more than 3 seconds at any time, you will enter the setting state.At this point, the "stop" indicator light is on, and the failure indicator light is always on.
2.Addition and subtraction of setting values:
The set value can be added by pressing the start button "RUN" on the controller panel. The set value can be added by pressing the start button for a short time, and the set value can be rapidly increased by pressing the admission time. In the same way, the set value can be reduced by pressing the STOP button on the controller panel.
3.Change the type of setting parameter:
Hold down the "Esc" key to switch between parameter types.
4.Exit setting status:
If there is no operation for 7 consecutive seconds, the setting value is written to E2PROM for saving, and the shutdown state is entered
Control function:
1-- Start button (This button can be used to start the compressor.Indicator light (8) is on, indicating that EⅡ computer controller is running.)
2--Display (displays information about the compressor's working status, maintenance and faults)
3--Scroll key (this key can be used to scroll up or down the display)
4--tab stop key TAB (press this key, you can select the parameter marked by the horizontal arrow, and you can only modify the parameter with the horizontal arrow behind it.)
5--Function keys (Function keys can be used to control and set the compressor)
6--Power indicator (indicating that the power is on)
7--Comprehensive alarm indicator (if there is an alarm, maintenance alarm, the indicator will light up)
8--Auto run indicator light (indicating that the computer controller is running automatically)
9--Stop button (press this button to stop the compressor. (8) will go out. After running for 30 seconds under unloaded conditions, the compressor will stop running)
S3-Emergency stop button (press this button to immediately stop the compressor in an emergency, after troubleshooting, pull out the button to release the lock.)
If you don't find the part number you want in my online shop, please do not hesitate to contact us, Maybe I can check it for you. At the same time, we are a factory and can also customize unconventional filter elements for you at any time.
Control Panel: