Intake Valve 1613683600 For Atlas Copco Air Compressor

Common faults

1,Is not loaded

The intake valve does not load the main reasons are: the solenoid valve does not get electricity; Solenoid valve damage; Solenoid valve with impurities caused by bad action or exhaust port blockage; Due to the deterioration of lubricating oil caused by the intake valve piston seal ring and cylinder friction increased and cannot be reset; The accommodating valve controls the closing of the intake valve. Elimination method: check the equipment circuit, to ensure that the solenoid valve is normal; Replace the solenoid valve coil or the entire solenoid valve body; Remove the solenoid valve to remove internal impurities; Clean the oil stains inside the intake valve, clean the oil stains inside the cylinder of the intake valve, and replace the high-quality lubricating oil; It is not recommended for non-professionals to adjust the adjusting valve (module) of the intake valve.

2,Not unloaded

The intake valve does not unload the main reasons are: the solenoid valve is not powered off; Solenoid valve damage; The small hole in the solenoid valve is blocked; The cut-off hole in the intake valve is blocked; The unloading speed is too fast. Elimination method: check the circuit, restore the solenoid valve normal; Replace the solenoid valve coil or the entire solenoid valve body; Open the solenoid valve to remove internal impurities; Open the intake valve to remove impurities in the closure hole; Adjust the discharge speed, increase the pipe diameter or add an elbow.

32, Fuel injection of the intake valve

The main reasons for the injection of the intake valve are: poor oil and gas separator; Oil return check valve is blocked; The air filtration effect is not good, the inlet valve core sealing surface adhesion impurities caused by poor sealing; Compressor working environment is bad, inlet valve piston and spring seat matching pair wear. Elimination method: check the oil and gas separator, and replace the new oil core; Remove the oil return check valve, remove the internal impurities of the check valve; Check the air filter, and replace the new air filter, air inlet valve pipe clean; Shorten the maintenance period and suggest the user to improve the compressor working environment

Product Name Intake valve
Product Number 1613683600
Use Atlas Copco Compressor
Brand QINGDAO FUTAI
Material Strict implementation of air compressor parts technical standard
MOQ 1 PC
Delivery time 3-5 days

Intake Valve

1613683600 Air Compressor Intake Valve For Atlas Copco Air Compressor

Send your message to this supplier
Send Now

1613683600 Air Compressor Intake Valve For Atlas Copco Air Compressor

Ask Latest Price
Brand Name :
QINGDAO FUTAI
Model Number :
1613683600
Certification :
ISO 9001:2015
Place of Origin :
CHINA
MOQ :
1
Packaging Details :
Carton, Wooden cases, Plastic bag, etc, make the package as your requirement.
Contact Supplier
1613683600 Air Compressor Intake Valve For Atlas Copco Air Compressor
1613683600 Air Compressor Intake Valve For Atlas Copco Air Compressor

Qingdao Futai Electromechanical Technology Co. Ltd.

Active Member
5 Years
shandong, qingdao
Since 2010
Business Type :
Manufacturer, Agent, Importer, Exporter, Trading Company, Seller
Total Annual :
100000-160000
Employee Number :
10~100
Certification Level :
Active Member
Contact Supplier
Submit Requirement