80 PLUS power supply 500w Desktop PSU RPD500-60EGN
The Product Features
PC PSU Introduction
The PC PSU DESCRIPTION
This specification describes a 500 watts power supply. With 6 output, and remote ON/OFF control for ATX-12V system and a “Power factor correction (active PFC)” circuit at 100V-240Vac.
APPLICATION: Desktop
WATTAGE: 500W
DIMENSION : 140mm(L) x 150mm(W) x 86mm(H)
PRODUCT HIGHLIGHT
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Output Rise Time:
Hold up Time: 115V/60Hz 17mSec. Minimum@100% Load,
GENERAL SPECIFICATION
ENVIRONMENTAL SPECIFICATION
Output Voltage and Current Rating
+3.3V | +5V | +12V1 | +12V2 | -12V | +5Vsb | |
Ripple-Noise(R-P) mV | 50mV | 50mV | 50mV | 120mV | 200mV | 50mV |
Regulation Load % | ±5% | ±5% | ±5% | ±5% | ±10%% | ±5% |
Output Max.(A) | 24A | 24A | 18A | 18A | 0.3A | 3.5A |
Output Min.(A) | 0.1A | 0.2A | 0.1A | 0A | 0A | 0A |
NOTES
1) +3.3V & +5V total output not exceed 130W.
When +5V is load to 22A, the +3.3V maximum load is 3A. When +3.3V is load to 24A, the +5V maximum load is 10A.
(2) +12V1 & +12V2 total output not exceed 432W(36A).
(3) All outputs shall be safety-isolated from the AC mains and share a common return. This common return must be connected to supply chassis.
(4) Voltages and ripple are measured at the load side of mating connectors with a 0.1uF monolithic ceramic capacitor paralleled by a 10uF electrolytic capacitor across the measuring terminals.
This content is subject to change, please refer to specification for more detail.