Electrical Specification | ||
ITEM | CONDITION | SPECIFICATION |
1.1 Rated Input Voltage | 100Vac - 240Vac | |
1.2 Input Voltage Range | Continuously | 90Vac to 264Vac |
1.3 Input Frequency Range | Continuously | 47Hz to 63Hz |
1.4 Input Current | 100Vac - 240Vac 47Hz to 63Hz | 2.4A – 0.9A |
1.5 Efficiency | 115Vac, 60Hz | ≥ 87% |
230Vac, 50Hz | ≥ 89% | |
100W Load, after warm-up 10 mins | ||
1.6 Inrush Current | 115Vac, | Shall be less than the rating of PSU critical component. |
230Vac, | (Including rectifiers, fuse surge and current limiting device) | |
100% Rated Load | ||
1.7 Power Saving | 115Vac, 63Hz | ≤ 0.21W |
230Vac, 47Hz | ≤ 0.21W | |
NO Load | ||
1.8 Leakage Current | 264Vac, 60Hz | |
Touch Current | ≤ 0.25mA | |
Earth Leakage Current | ≤ 0.75mA | |
2. Output Characteristics: | ||
ITEM | CONDITION | SPECIFICATION |
2.1 Output Rated Voltage | 24.0V | |
Convection air cooling | 0 A to 4.16 A | |
2.2 Output Current | 7 CFM Forced air cooling | 0 A to 6.25 A |
2.3 Output Voltage Regulation | 24.0V ± 3 % | |
2.4 Fan Driver | 24.0V Main Power load 2.5W Min. | 12.0V ± 10 % |
500mA Max. | ||
2.5 Output Voltage Ripple and Noise | 115Vac, 47Hz to 63Hz 230Vac, 47Hz to 63Hz | ≤ 240mVp-p |
(0.1uF/100V Ceramic Cap. and 10uF/63V Tantalum Cap. | ||
Paralleled between the output connector, BW=20M Hz) | ||
2.6 Turn-On Delay Time | At 100Vac / 100W load, output voltage within regulation | ≤ 1000 mSec. |
2.7 Hold Up Time | 100W Load, 115Vac / 230Vac 150W Load, 115Vac / 230Vac Output voltage within regulation | ≥ 20 ms |
≥ 8 ms | ||
2.8 Load Transient Response | The test step: the load regulation 0~50% or 50%~100%@1A/us,50Hz, at line voltage. | 24.0V ± 5 % |
3. Protection Characteristics: | ||
ITEM | CONDITION | SPECIFICATION |
3.1 Short Circuit Protection | When an internal fault occurs, or an external fault (overload or short circuit) is applied to the power supply, the power supply shall shut down and enter auto-recovery mode | Auto-recovery and no damage |
3.2 Over Voltage Protection | The output trip voltage shall not exceed 35V. That will be return to normal state by | Shut down and latch. |
AC reset. | ||
3.3 Over Power Protection | When an internal fault occurs, or an external fault is applied to the power supply, such as an overload or short | Auto-recovery and no damage |
circuit is applied to the output, the power supply shall shut down and enter | ||
auto-recovery mode. | ||
3.4 Over Temperature Protection | The power supply will shutdown during abnormal thermal rise occurs. Returning back to normal operation when the power supply is cooled down and remove the AC mains input OFF and ON to reset the system. | Shut down and latch. |
4. Environmental Characteristics: | ||
ITEM | CONDITION | SPECIFICATION |
4.1 Safety Standard | UL ES 62368-1 | Design to meet |
CSA C22.2 No. 62368-1 TUV EN 62368-1 | ||
IEC 62368-1 | ||
4.2 EMC | EN55032 EN61000-3-2 EN61000-3-3 EN55024 | Design to meet |
4.2.1 EMI : | 115Vac, 60Hz | FCC CFR PART 15B CISPR 32, EN55032 Class B |
Conducted Emission Radiated Emission | 230Vac, 50Hz | |
100% Rated Load | ||
4.2.2 Input Current Harmonic Refer to EN61000-3-2 | Harmonic distortion | Class D |
4.2.3 Line Flicker | ||
Refer to EN61000-3-3 | ||
4.2.4 Electron Static Discharge (Refer to EN61000-4-2 Energy Storage Capacitor 150pF; Discharge Resistor 330Ω) | Air Discharge: ±8KV min. Contact Discharge: ±6KV min. | Normal operation shall be continued |
4.2.5 Radiated Immunity Refer to EN61000-4-3 | 3V/m | Normal operation shall be continued |
4.2.6 Electric Fast Transients Refer to EN61000-4-4 | Impulse: ±1KV L, N | Normal operation shall be continued |
4.2.7 Lightning Surge Refer to EN61000-4-5 | ±2KV differential mode | Normal operation shall be continued |
±4KV common mode | ||
4.2.8 Conducted Immunity Refer to EN61000-4-6 | 3V rms | Normal operation shall be continued |
4.2.9 Magnetic Field Immunity Refer to EN61000-4-8 | 3A/m | Normal operation shall be continued |
4.2.10 Voltage Dip Immunity Refer to EN61000-4-11 | 230Vac, 50Hz | Criteria Class A Class A Class B |
>95% reduction for 10 ms (0.5 cycles) | ||
30% reduction for 500 ms (25 cycles) | ||
>95% reduction for 5000 ms (250 cycles) | ||
4.3 Cooling | Convection air cooling | 100W |
7 CFM Forced air cooling | 150W | |
4.4 Dielectric Strength (Hi-Pot) | Input to Output Input to Ground Output to Ground | 3000Vac |
1500Vac | ||
500Vac | ||
4.5 Temperature | Operating | -20°C to +70°C |
Storage | -40°C to +85°C | |
Derating | Derate from 100% at +50°C, linearly to 50% at +70°C | |
![]() | ||
4.6 Relative Humidity | Operating Storage | 10% ~ 90% (non–condensing) |
5% ~ 95% (non–condensing) | ||
4.7 Atmospheric Pressure | Operating Storage | 5000M max. |
4.8 Vibration | Operation, 0.01g²/Hz at 5 Hz s fffloping to 0.02g²/Hz at 20 Hz, and maintaining 0.02g²/Hz from 20 Hz to 500 Hz. The area under the PSD curve is 3.13gRMS. The duration shall be 20 | Normal operation shall be continued |
minutes per axis for all three axes on all samples. | ||
4.9 MTBF | At output power 100W and +25°C ambient, calculated per MIL-HDBK-217F | > 100,000 hours |
4.10 RoHS | Lead and it’s compound (Pb) Mercury and it’s compound (Hg) Cadmium and it’s compound (Cd) | < 1000 PPM |
Hexavlent chromium compound (Cr+6) PBB | < 1000 PPM | |
PBDE | < 100 PPM | |
< 1000 PPM | ||
< 1000 PPM | ||
< 1000 PPM | ||
5. Mechanical Characteristics : | ||
ITEM | CONDITION | SPECIFICATION |
5.1 Dimension (Length x Width x Height) | 127.0mm * 76.2mm * 27.0mm (5 “ * 3 “ * 1.06 “) | |
5.2 Weight | 168g (typical) | |
5.3 Input Connector | Input Connector (IN1) | B2P3-VH(LF)(SN), JST |
or Equivalent | ||
5.4 Output Connector | Input Connector (CN200) | B6P-VH(LF)(SN), JST |
or Equivalent |