Portable Type AC Hipot Tester , AC 6KV DC 5KV Safety Tester , Programmable , Arc Detection
I. Product Description
The 9911/9912 Hipot tester is a high voltage and programmable safety tester with an output voltage of AC5kV and DC6KV. It can be widely used in the safety tests of household appliances, transformer, electrical equipments and components.
II. Refer Standard
III. Advantage
IV. Technical Data and optional model
MODEL | 9911A | 9911B | 9912A | 9912B | |||||
AC | Output voltage | range | 0.050~5.000kV | ||||||
accuracy | ±2% reading +5V | ||||||||
resolution | 1V | ||||||||
Max. Output capacity | 75W | 100W | |||||||
Max. Rated current | 15mA | 20mA | |||||||
Current gear | 2mA,15mA | 2mA,20mA | |||||||
Lower limit current | (0~15.00)mA, 0=Do not judge the lower limit |
(0~20.00)mA, 0=Do not judge the lower limit |
|||||||
Output waveform | Sine wave | ||||||||
Output waveform distortion | ≤ 2% (no load or pure resistive load) | ||||||||
Crest factor | 1.3~1.5 | ||||||||
Output signal type | DDS+ amplifier | ||||||||
AC | Voltage rise time | 0.3s ~ 999.9s 0 = voltage rise time off |
|||||||
Test time | 0.3s ~ 999.9s 0 = continuous test |
||||||||
Voltage drop time | 0.3s ~ 999.9s 0 = voltage fall time off |
||||||||
Interval time | 0.3s~999.9s 0=Interval time off |
||||||||
DC |
Output Voltage |
range | (0.050~6.000)kV | (0.050~6.000)kV | |||||
accuracy | ±(2%reading+5V) | ±(2%reading+5V) | |||||||
resolution | 1V | 1V | |||||||
Max.output capacity | 30W | 60W | |||||||
Max.rated current | 5.000mA | 9.999mA | |||||||
Current gear | 2mA,5mA | 2mA,10mA | |||||||
Current lower limit | (0~5.000)mA, 0=Do not judge the lower limit |
(0~9.999)mA, 0=Do not judge the lower limit |
|||||||
Ripple coefficient | ≤5%, 6kV/5mA | ≤5%, 6kV/10mA | |||||||
Discharge time | ≤200ms | ≤200ms | |||||||
Max. Charging current | 5mA | 9.999mA | |||||||
Voltage rise time | 0.3~999.9s 0=voltage rise time off |
0.3~999.9s 0=voltage rise time off |
|||||||
Test time | 0.3~999.9s 0=Continuous test |
0.3~999.9s 0=Continuous test |
|||||||
Voltage drop time | 0.3~999.9s 0=voltage drop time off | 0.3~999.9s 0=voltage drop time off | |||||||
Interval time | 0.3~999.9s 0=interval time off |
0.3~999.9s 0=interval time off |
|||||||
Voltage meter |
range | 0.050kV~6.000kV | |||||||
accuracy | ±(2%reading+5V) | ||||||||
resolution | 1V | ||||||||
Display value | RMS value | ||||||||
Current meter |
Test range | AC | 0 ~ 20mA | ||||||
DC | 0 ~ 10mA | ||||||||
resolution | AC | 2mA gear:1uA, 20(15mA)mA gear,10uA | |||||||
DC | 2mA gear :1uA, 10(5mA)mA gear,10uA | ||||||||
accuracy | ±(2%+5words) | ||||||||
Error Offset current | 0 ~ 2mA | ||||||||
Timer |
range | 0.1s~999.9s | |||||||
Accuracy/resolution | ±1%/0.1s |
V.Supply list