SONTUOEC LC1-D Magnetic AC Contactor LC1-D09 LC1-D12 LC1-D18 LC1-D25 LC1-D32 LC1-D40 LC1-D50 LC1-D65 LC1-D80 LC1-D95 with tranparent cover
Product Description
LC1-D Series Contactors are divided into AC contactors (voltage AC), which are used in power, distribution and power applications. Contactors in a broad sense refer to electrical appliances that use coil current to generate magnetic field and close contacts in order to control load.
Because the main circuit of AC and DC can be switched off quickly and the device of high current control (up to 95A) circuit can be connected frequently, contactor is often used for motor as control object, and also for controlling power loads such as plant equipment, electric heater, working mother machine and various power units. Contactors can not only connect and cut off electricity. The circuit also has the function of low voltage release protection. Contactor control capacity is large, suitable for frequent operation and long-distance control, is one of the important components of automatic control system.
LC1-D AC Contactor is suitable for using in the circuits up to the rated voltage 660v, AC 50hz or 60hz, rated current up to 95A, for making , breaking frequently starting &machine-interlocking device etc,it becomes the dalay contactor, mechanical interlocking contactor,star-delta starter.with the thermal relay, it is combined into the electromagnetic starter.The contactor is produced according to IEC60947-2,VDE0660&BS5442
SPECIFICATION
Type | LC1-D09 | LC1-D12 | LC1-D18 | LC1-D25 |
Rated workingcurrent (A) | AC3 | 9 | 12 | 18 | 25 |
AC4 | 3.5 | 5 | 7.7 | 8.5 |
Standardpower ratingsof 3-phase motors 50/60Hz incategory AC-3 | 220/230V | 2.2 | 3 | 4 | 5.5 |
380/400V | 4 | 5.5 | 7.5 | 11 |
415V | 4 | 5.5 | 9 | 11 |
500V | 5.5 | 7.5 | 10 | 15 |
660/690V | 5.5 | 7.5 | 10 | 15 |
Rated heat current (A) | 20 | 20 | 32 | 40 |
Electrical life | AC3 (x104) | 100 | 100 | 100 | 100 |
AC4 (x104) | 20 | 20 | 20 | 20 |
Mechanical life (x104) | 1000 | 1000 | 1000 | 1000 |
Number of the contacts | 3P+NO |
3P+NC |
Type | | LC1-D32 | LC1-D40 | LC1-D50 | LC1-D65 | LC1-D80 | LC1-D95 |
Rated workingcurrent (A) | AC3 | 32 | 40 | 50 | 65 | 80 | 95 |
AC4 | 12 | 18.5 | 24 | 28 | 37 | 44 |
Standardpower ratingsof 3-phase motors 50/60Hz incategory AC-3 | 220/230V | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
380/400V | 15 | 18.5 | 22 | 30 | 37 | 45 |
415V | 15 | 22 | 25 | 37 | 45 | 45 |
500V | 18.5 | 22 | 30 | 37 | 55 | 55 |
660/690V | 18.5 | 30 | 33 | 37 | 45 | 55 |
Rated heat current (A) | 50 | 60 | 80 | 80 | 125 | 125 |
Electrical life | AC3 (x104) | 80 | 80 | 60 | 60 | 60 | 60 |
AC4 (x104) | 20 | 15 | 15 | 15 | 10 | 10 |
Mechanical life (x104) | 800 | 800 | 800 | 800 | 600 | 600 |
Number of the contacts | 3P+NC+NO |
Standard Control Circuit Voltage
Volts | 24 | 42 | 48 | 110 | 220 | 230 | 240 | 380 | 400 |
50Hz | 440 | 500 | 600 | 50Hz | B5 | D5 | E5 | F5 | M5 |
60Hz | U5 | Q5 | V5 | N5 | R5 | S5 | Y5 | 60Hz | B6 |
50/60Hz | E6 | F6 | M6 | - | U6 | Q6 | - | - | R6 |