Advantage:
◆ Upper computer programming software compatible with Works 2/GX Developer8.86 (supports Ladder diagram and SFC language, does not support structured programming/labels).
◆ Powerful, compatible with FX3G/FX3U/FX3S PLC, high processing speed.
◆ Military level 32 bit CPU adopted, which is faster and more adapted to industrial environment of high electromagnetic interference.
◆ Special encryption, prevent illegal reading thoroughly. 8-bit encryption, 12345678 as password can thoroughly prevent reading of ladder logic program.
◆ Clock supported, rechargeable battery adopted.
Parameter:
Display | Dimension | 134*102*34mm |
Cutout size | 120*94mm | |
Type | 4.3"TFT | |
Feature | 60K-color resistive touch screen, supports portrait display | |
Memory | RAM | 64MB |
ROM | NOR Flash 8MB | |
CPU | 32bit CPU 408MHz | |
I/O | DI/DO | Max 12DI/12DO |
DI/DO level | Input: Passive NPN, public terminal isolated Transistor output: Low level NPN, COM connect to negative; Relay output: Normally open dry contact | |
DO type and load | Relay MR/MOS tube, MOS tube: 2A/point, 4A/4 point COM, 5A/12 point COM; MR: 2A/point, 5A/12 point COM. | |
Analog I/O (optional) | Max 4AI/2AO | |
AI type (optional) | Thermocouple E/E_/K/K_/S/S_/T/T_/J/J_ / PT100/ PT1000/ NTC10K/ NTC50K/ NTC100K/ 0~10V/ 0~5V/ 0~20mA/ 4~20mA/ mixed | |
AO type (optional) | 0~10V /0~5V/ 0~20mA/ 4~20mA/ mixed | |
High-speed function | High-speed counting | Single phase 6 channel 60KHz, or 2 AB 60KHz + 1 AB 10KHz, or 2 ABZ 60KHz + 1 AB phase 10 KHz |
High-speed pulse | 8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz. High-speed counting + high-speed pulse < 480KHz | |
Connection | HMI | Type-C HMI download port (can download PLC program through the USB penetrating function), RS232 port |
PLC | 1 TYPE-C, 1 RS232 (program port) | |
1 RS485 or 2 RS485 COM ports (one of which is changed from the default RS232 port); 1 WIFI (occupy default RS232 port) | ||
Software | HMI | Coolmay mView HMI Programming Software |
PLC | Compatible with Mitsubishi GX Developer 8.86 and WORKS 2 |
Precautions for PLC programming:
The PLC is compatible with GX Developer8.86/GX Works2 and below. If you use other versions of software, incompatibility may occur.
When the PLC program is downloaded, there is a prompt error: Cannot specify the com port,
GX 8.86 software: Online-Transfer settings change com port;
Works 2: All targets-Change the com port in all connected targets;
If there is a communication abnormality, cable abnormality and other prompts, remove it by cutting off the power, checking the cable, checking whether the power supply is normal, or replacing the computer.
In the GX Developer8.86 software version, choose the figure:
In the Works 2 software version, choose the figure: (Note: the label is forbidden)