Multichannel potentiostat model CS310X (Option A: 4-channel, EIS*1)
Corrtest Multichannel potentiostat/ galvanostat/EIS is a versatile instrument offering 8 slots.
Multichannel potentiostat/ galvanostat model CS310X (Option A) is the 4-channel potentiostat. 4 slots are occupied with potentiostat boards. The rest 4 slots are idle for future adding potentiostat board(s). Option A equals that you have 4 sets independent potentiostat/galvanostat.
EIS module (10μHz~1MHz) is equipped in only ONE channel. Each channel potential control range is ±10V, current control range ±1A, can meet experiment requirement for most people.
Full floating module and electrical isolation design guarantee each channel is totally independent, which ensures accurate data and efficient simultaneous measurements.
Multichannel potentiostat (±1A, ±10V) Each channel is independent | |||
Model: CS310X | |||
Option A 4-channel, | Option B 4-channel, | Option C 8-channel, | Option D 8-channel, |
Application
- Reaction mechanism of Electrosynthesis, electrodeposition (electroplating), anodic oxidation.
- Electrochemical analysis, electro-catalysis, sensor;
- New energy materials, advanced functional materials, photoelectronic materials;
- Corrosion study of metals in water, concrete and soil etc;
- Fast evaluation of corrosion inhibitor, water stabilizer, coating and cathodic protection efficiency.
Specifications of CS310X multichannel potentiostat | |
Number of channels with boards: 4 | Channel insulation resistance: >100MΩ |
Communication: Ethernet | Lower-pass filter: covering 8-decade |
Potential control range: ±10V | Constant current control range: ±1A |
Potential accuracy: 0.1%×full range±1mV | Current accuracy: 0.1%×full range |
Potential resolution:10μV(>100Hz), 3μV(<10Hz) | Current resolution: 1pA |
Potential rise time: <1μs(<10mA), <10μs(<2A) | Current range: 2nA ~1A, 10 ranges |
Reference electrode input impedance: 1012Ω||20pF | Maximum current output: 1A |
Compliance voltage: ±21V | Current increment during scan: 1mA @1A/ms |
CV and LSV scan rate: 0.001mV~10000V/s | Potential increment during scan: 0.076mV@1V/ms |
CA and CC pulse width: 0.0001~65000s | DPV and NPV pulse width: 0.0001~1000s |
SWV frequency:0.001~100KHz | CV minimum potential increment: 0.075mV |
AD data acquisition:16bit@1MHz,20bit @1kHz | IMP frequency:10μHz~1MHz |
DA resolution:16bit, setup time:1μs | Current and potential range: automatic |
Operating System requirements: Windows 10 /11 | Weight: 12.5 Kg Dimensions: 40*40*14cm |
Electrochemical Impedance Spectroscopy (EIS) | |
Signal generator | |
Frequency range: 10μHz~1MHz | AC signal amplitude: 1mV~2500mV |
Frequency accuracy: 0.005% | Signal resolution: 0.1mV RMS |
DDS output impedance: 50Ω | DC Bias: -10V~+10V |
Wave distortion: <1% | Waveform: sine wave, triangular wave, square wave |
Scan mode: Logarithmic/linear, increase/decrease | |
Signal analyzer | |
Maximum integral time:106 cycles or 105s | Measurement delay:0~105s |
Minimum integral time:10ms or the longest time of a cycle | |
DC offset compensation | |
Potential compensation range: -10V~+10V | Current compensation range: -1A~+1A |
Bandwidth adjustment: automatic and manual, 8-decade frequency range |
Advantages
High current/voltage: Applied potential range ±10V, current ±1A. It can meet the needs of most studies.
EIS technique: Built-in EIS (10μHz~1MHz) is equipped in ONE channel.
Warranty: 5 years warranty. We're the manufacturer, and our engineers will provide technical support anytime you need.
Low cost: The price includes instrument host, software (experiment control & data processing), necessary cables, dummy cell. No other charges.
Reliability &quality: We've been in the market for 20 years, and now is the No. 1 brand of potentiostat product in China
Techniques in each channel-Option A
Stable polarization
Transient Polarization
Chrono Method
Voltammetry
Electrochemical Impedance Spectroscopy (EIS)(EIS is included in only one channel)
Corrosion Measurements
Battery test
Amperometric
# There is corresponding stripping technique
Simultaneous Measurements
You can run a same experiment for each channel at the same time. Set the same parameters for
each experiment once and run all independently. It's especially useful when you have many samples for one single test.
You can also choose different techniques in each channel. Set the parameters for each
experiment one by one, and run each experiment independently. As is shown in right picture, EIS, Galvanostatic charge & discharge, Cyclic Voltammetry, and polarization curve test are tested.