20A Current Booster High Current High Power Potentiostat
CS2020B Current Booster
Single-channel potentiostat (CS350M/ CS310M/ CS300M etc) can achieve maximum±2A/10V output when it’s used alone. This value is ±1A/10V for each channel of bipotentiostat (CS2350M/CS2150M) and multichannel potentiostat (CS310X).
A current booster CS2020B can be connected to single-, bi-, or multi-channel potentiostat to boost the current (up to 20A). Please note that one set CS2020B can boost only one channel of bi- / multi-channel potentiostat.
When not connected the booster, the potentiostat can also be used alone.
CS2020B current booster +single channel potentiostat (such as CS350M)
CS2020B current booster +multi-channel potentiostat(framed in red)
Fig. 1: Curve for galvanostatic experiment- output constant current as high as 20A
Fig. 2: Connection of CS2020B with battery core anode and cathode
Fig. 3: EIS results of CATL-LAE895 battery core
Key specifications (when combination of CS2020B+potentiostat)
Potential range: ±10V
Current range: ±20A
Current range: 20Afixed range
Compliance voltage: ±13V (when output±20Alimit current, maximum output ±10V@20A)
EIS Frequency range: =50KHz
Communication: RS485
Techniques (when combination of CS2020B+potentiostat)
Stable polarization
• Open Circuit Potential (OCP)
• Potentiostatic (I-T curve)
• Galvanostatic
• Potentiodynamic (Tafel plot)
• Galvanodynamic (DGP)
Transient Polarization
• Multi Potential Steps
• Multi Current Steps
• Potential Stair-Step (VSTEP)
• Galvanic Stair-Step (ISTEP)
Chrono Method
• Chronopotentiometry (CP)
• Chronoamperametry (CA)
• Chronocaulometry (CC)
Voltammetry
• Linear Sweep Voltammetry (LSV)
• Cyclic Voltammetry (CV)
Electrochemical Impedance Spectroscopy (EIS)
• EIS vs Frequency (IMP)
• EIS vs Time (IMPT)
• EIS vs Potential (IMPE)(Mott-Schottky)
Battery test
• Battery Charge and Discharge
• Galvanostatic Charge and Discharge (GCD)
• Potentiostatic Charging and Discharging(PCD)
• Potentiostatic Intermittent Titration Technique(PITT)
• Galvanostatic Intermittent Titration Technique(GITT)
Corrosion Measurements
• Cyclic polarization curve (CPP)
• Linear polarization curve (LPR)
• Electrochemical Potentiokinetic Reactivation (EPR)
• Electrochemical Noise (EN)
• Zero resistance Ammeter (ZRA)
Standard supply for CS2020B booster:
- CS2020B current booster instrument*1 set
- Power cable *1 pcs
- DB9 serial port connection cable *2 pcs (1 for replacement in the future in case it’s broken)
- DB15 connection cable*2 pcs (1 for replacement)
- Potential sampling cable*2 pcs (1 for replacement)
- CS2020B Specialized electrode cable (alligator electrode cable*2 and copper terminal electrode cable*2, 1 pcs each for replacement)
- High power dummy cell *1