Rated Load :
max 3000kg
Voltage: :
DC19-29V
Cable length: :
8m, 4 blank wire
Installation location :
under the rope hitch plate
Display mode :
Weight/percentage
Structure :
Split type
Alarm relay output :
5(overload,full load,empty load, optical,acousti
Description

SUMMIT Split type elevator overload control system 3000kg RHP-F-OMS-560 installed at elevator the rope hitch ;oint overload measurement control device
Installation loacation: installed at wire rope hitch point :OMS-560-RHP-F-3T(rated load: 3000kg)
SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device
Description:
The elevator over load control device OMS-560-RHP-F is one kind of split type load weighing solution ,and it consists of 1 or 2 pressure load sensor RHP-F and a controller OMS-560, and the pressure load cell is typically plated under the wire rope hitch plate. This method have no impact on the crossing height requirements and are there-fore especially suitable for new installation and modernization projects.
Features:

  1. Cost efficient and precise method
  2. Very easy to install
  3. Static load at fixing point(under the plate of wire rope attachment)
  4. Suitable for the new installations and modernization project
  5. Menu-guided operation
  6. 5 relays output overload,full,half empty,optical, audio output
  7. DIN Rail or on flat surface mounting with screws
  8. IP-65 rated plastic box.
  9. Integrated software to correct weight increases due to compensating chain.
  10. Display load as well as percentage
  11. Protecting important data from being disturbed by password
  12. Automatic correction of zero drift, makes the equipment in optimum stage
  13. Self-learning function, regulating high floor additional weight error
  14. Control equipment swap entirely,self-diagnosis and alarming
  15. Self-learning operating conducted by any fixed load

Control Unit:OMS-560
Operation Voltage AC/DC16-48V Sensor operation voltage DC5V
Nominal power 4W Signal Hold Voltage AC/DC12-45V
Input Channel (Load Cell ) 2 Measuring precision 0.1%
Relay Number

5(overload,full,half empty,optical, audio output)

Operation temperature -45degree-+85degree
Contact Load 8A250VAC,5A 250VAC,5A 30VDC Size 90x84x58mm
Display Type 4 digits 0.56 inch LED Weight 265g
Display mode Weight/percentage Shell material ABS


Model: RHP-F
Rated Load 3000kg/PC Output Resistance 700M+/-2 ohm
Rated Output 2.0+-0.02%mv/v Safe Overload 150% F.S.
Total error +/-0.5% F.S Ultimate Overload 200% F.S.
Repeatability +/-0.5% F.S. Construction material Stainless Alloy steel
Creep 30min +/-0.05% F.S/30min Protection Class IP68
Zero Balance +/-1% F.S. Insulation impedance ≥5000Ω
T C SPAN +/-0.02% F.S./10 degree Celsius Cable length 8m(black)
Operation temperature range -30 to 70 degree Celsius Connection type 4 bank wire
Input Resistance 760+/-10 ohm
Excitation
DC 5-12V


Wiring Diagram:
SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device
4 blank wires:
SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device
Installation location&Size:
SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device
SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device

Instruction:
The purpose of the SUMMIT Load Weighing system is to measure the load in the elevator and pro-vide usable information about the load to the elevator controller. This information is used forpre-torquing and for dispatching decisions, e.g. light load anti-nuisance, heavy load and over-load.
The system usually consists of a sensor or group of sensors mounted on the elevator’s some position such as clamping on wire rope, or under cabin, under the wire rope plate installation and a control unit. The sensor(s) provide a signal to the control unit directly related to the amount of load in the cab. The load weighing control accepts this signal and provides usable data to the elevator controller in the form of an analog signal and discrete relay contacts.

Using SUMMIT solutions loads can be weighed in every imaginable situation.We offer you flexible, modular solutions for both requirements, and wide experience with modernization projects. we attention to detail in the design of their modular system allows great freedom to configure load weighing systems to suit all types of cabin.

Send your message to this supplier
Send Now

SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device

Ask Latest Price
Brand Name :
SUMT, ANT
Model Number :
OMS-560-RHP-F-3T
Place of Origin :
NINGBO CITY, CHINA
MOQ :
MOQ:10sets
Price :
USD80-150/PC
Payment Terms :
T/T, Western Union, MoneyGram,Paypal
Contact Supplier
SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device
SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device

Ningbo youte electric Co.,LTD

Verified Supplier
3 Years
ningbo
Since 1996
Business Type :
Manufacturer, Importer, Exporter, Seller
Total Annual :
15000000-20000000
Employee Number :
150~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement