Crawler crane models: XGC350
Max rated lifting capacity: 350t
Max lifting moment: 2400t.m
Typical working conditions
Main boom working conditions_Characteristics of main boom hook with boom end pulley auxiliary hook (HBS/1)
Main boom working condition_Working range of main boom main hook with arm end pulley auxiliary hook (HBS/1)
Main boom working condition_Working range of main boom main hook with arm end pulley auxiliary hook (HBS/1)
Main boom working condition_with arm end pulley auxiliary hook HBS/1_135t+50t main boom main hook performance (optional)
HBS/1 | Main boom length(m) | ||||||||||||
Radians | 24 | 30 | 36 | 42 | 48 | 54 | 60 | 66 | 72 | 78* | 84* | 90* | 96* |
(m) | t | t | t | t | t | t | t | t | t | t | t | t | t |
6 | 300.0 |
|
|
|
|
|
|
|
|
|
|
|
|
7 | 300.0 | 300.0 | 268.0 | 242.0 |
|
|
|
|
|
|
|
|
|
8 | 295.0 | 292.0 | 262.0 | 238.0 | 209.0 | 182.0 |
|
|
|
|
|
|
|
9 | 263.0 | 258.0 | 238.4 | 223.5 | 205.8 | 180.8 | 168.8 | 152.0 |
|
|
|
|
|
10 | 237.0 | 226.8 | 211.6 | 205.2 | 186.8 | 179.2 | 164.4 | 148.8 | 136.8 | 126.8 |
|
|
|
11 | 201.8 | 197.8 | 189.4 | 180.8 | 171.8 | 162.2 | 155.2 | 148.1 | 132.7 | 120.4 | 108.8 | 92.8 |
|
12 | 176.8 | 174.8 | 170.2 | 161.0 | 154.1 | 147.6 | 141.6 | 135.9 | 130.4 | 121.8 | 103.8 | 88.8 | 78.8 |
13 | 156.8 | 154.3 | 153.0 | 146.8 | 140.8 | 135.3 | 130.0 | 125.0 | 120.1 | 115.5 | 100.4 | 86.8 | 75.8 |
14 | 143.8 | 139.1 | 136.9 | 134.8 | 129.6 | 124.7 | 119.9 | 115.5 | 111.1 | 107.0 | 99.9 | 85.2 | 73.8 |
15 | 126.8 | 125.3 | 123.6 | 123.5 | 119.8 | 115.4 | 111.1 | 107.2 | 103.3 | 99.5 | 95.9 | 84.4 | 73.1 |
16 | 115.8 | 113.8 | 112.4 | 112.2 | 111.2 | 107.4 | 103.5 | 99.8 | 96.2 | 92.9 | 89.5 | 83.5 | 72.3 |
17 | 105.8 | 103.8 | 102.9 | 102.8 | 102.3 | 100.2 | 96.6 | 93.3 | 90.0 | 87.0 | 83.8 | 81.4 | 71.6 |
18 | 97.8 | 96.0 | 94.7 | 94.5 | 94.1 | 93.7 | 90.5 | 87.5 | 84.4 | 81.6 | 78.7 | 76.6 | 70.7 |
19 | 91.8 | 88.9 | 87.6 | 87.5 | 87.0 | 86.5 | 85.0 | 82.2 | 79.3 | 76.7 | 74.0 | 72.1 | 69.6 |
20 | 84.8 | 82.7 | 81.3 | 81.1 | 80.7 | 80.3 | 79.8 | 77.5 | 74.7 | 72.3 | 69.7 | 67.8 | 65.6 |
22 | 74.3 | 72.3 | 70.9 | 70.7 | 70.2 | 69.8 | 69.2 | 68.8 | 66.8 | 64.6 | 62.3 | 60.6 | 58.5 |
24 |
| 62.9 | 62.6 | 62.4 | 61.8 | 61.4 | 60.7 | 60.3 | 59.6 | 58.1 | 56.0 | 54.5 | 52.6 |
26 |
| 56.0 | 55.6 | 55.4 | 54.9 | 54.4 | 53.8 | 53.3 | 52.7 | 52.2 | 50.5 | 49.2 | 47.4 |
28 |
| 50.1 | 49.8 | 49.6 | 49.1 | 48.7 | 48.0 | 47.5 | 46.9 | 46.4 | 45.7 | 44.5 | 42.6 |
30 |
|
| 45.3 | 45.1 | 44.5 | 44.1 | 43.5 | 42.9 | 42.3 | 41.8 | 41.1 | 40.3 | 38.9 |
32 |
|
| 40.7 | 40.6 | 39.9 | 39.5 | 38.9 | 38.3 | 37.7 | 37.2 | 36.5 | 36.0 | 35.1 |
34 |
|
|
| 37.3 | 36.7 | 36.2 | 35.6 | 35.1 | 34.4 | 33.9 | 33.2 | 32.7 | 31.9 |
36 |
|
|
| 34.1 | 33.5 | 33.0 | 32.4 | 31.8 | 31.2 | 30.7 | 30.0 | 29.5 | 28.7 |
38 |
|
|
| 30.8 | 30.3 | 29.7 | 29.1 | 28.6 | 27.9 | 27.4 | 26.7 | 26.2 | 25.5 |
40 |
|
|
|
| 27.9 | 27.3 | 26.7 | 26.2 | 25.5 | 25.0 | 24.3 | 23.8 | 23.1 |
42 |
|
|
|
| 25.4 | 24.9 | 24.3 | 23.7 | 23.0 | 22.5 | 21.8 | 21.3 | 20.6 |
48 |
|
|
|
|
| 19.3 | 18.7 | 18.1 | 17.4 | 16.9 | 16.2 | 15.7 | 15.0 |
50 |
|
|
|
|
|
| 17.2 | 16.7 | 16.0 | 15.5 | 14.8 | 14.3 | 13.5 |
52 |
|
|
|
|
|
| 15.8 | 15.2 | 14.5 | 14.0 | 13.3 | 12.8 | 12.1 |
54 |
|
|
|
|
|
| 14.3 | 13.8 | 13.1 | 12.6 | 11.9 | 11.4 | 10.6 |
58 |
|
|
|
|
|
|
| 11.5 | 10.8 | 10.3 | 9.5 | 9.0 | 8.2 |
64 |
|
|
|
|
|
|
|
| 7.8 | 7.3 | 6.6 | 6.1 | 5.3 |
68 |
|
|
|
|
|
|
|
|
| 5.7 | 4.9 | 4.3 | 3.6 |
74 |
|
|
|
|
|
|
|
|
|
| 2.7 |
|
|
Notes:
1. The actual load must be deducted from the values in the table by the weight of the hook, sling and wire rope wrapped around the hook and the boom head.
2. The main boom length "*" mark combination must use a 1.31m waist rope, and the main boom length exceeding 78m must use an inclined wedge to assist the boom.
3. The tower arm rear pull plate must be removed from each boom section, and the tower arm guide pulley must be removed from the main boom reducer.
Main boom working condition_Characteristics of boom end pulley auxiliary hook with main boom main hook (HBS/2)
Main boom working condition_working range of boom end pulley auxiliary hook with main boom main hook (HBS/2)
Main boom working condition_working range of boom end pulley auxiliary hook with main boom main hook (HBS/2)
Main boom working condition_with main boom main hook HBS/2_130t+50t arm end pulley auxiliary hook performance
HBS/2 | Main boom length (m) | |||||||||||
Radians | 24 | 30 | 36 | 42 | 48 | 54 | 60 | 66 | 72 | 78* | 84* | 90* |
(m) | t | t | t | t | t | t | t | t | t | t | t | t |
7 | 28.0 |
|
|
|
|
|
|
|
|
|
|
|
8 | 28.0 | 28.0 | 28.0 |
|
|
|
|
|
|
|
|
|
9 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
|
|
|
|
|
|
|
10 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
|
|
|
|
|
11 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
|
|
|
12 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
|
13 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
14 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
15 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
16 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
17 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
18 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
19 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
20 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
22 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
24 |
| 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
26 |
| 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
28 |
| 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
30 |
|
| 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
32 |
|
| 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
34 |
|
|
| 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 |
36 |
|
|
| 28.0 | 28.0 | 28.0 | 27.9 | 27.6 | 27.2 | 26.9 | 26.6 | 26.4 |
38 |
|
|
| 28.0 | 28.0 | 28.0 | 27.7 | 27.1 | 26.4 | 25.8 | 25.1 | 24.7 |
42 |
|
|
|
| 24.0 | 23.6 | 23.0 | 22.5 | 21.8 | 21.2 | 20.4 | 19.9 |
44 |
|
|
|
|
| 21.8 | 21.2 | 20.7 | 20.0 | 19.4 | 18.6 | 18.1 |
48 |
|
|
|
|
| 18.2 | 17.5 | 17.0 | 16.3 | 15.8 | 15.1 | 14.6 |
50 |
|
|
|
|
|
| 16.1 | 15.6 | 14.9 | 14.4 | 13.7 | 13.2 |
54 |
|
|
|
|
|
| 13.3 | 12.8 | 12.1 | 11.6 | 10.9 | 10.4 |
58 |
|
|
|
|
|
|
| 10.5 | 9.9 | 9.4 | 8.6 | 8.1 |
64 |
|
|
|
|
|
|
|
| 6.9 | 6.5 | 5.7 | 5.2 |
68 |
|
|
|
|
|
|
|
|
| 4.9 | 4.1 | 3.6 |
Notes:
1. The actual load must be deducted from the values in the table by the weight of the hook, sling and wire rope wrapped around the hook and the boom head.
2. The main boom length "*" mark combination must use a 1.31m waist rope, and the main boom length exceeding 78m must use an inclined wedge to assist the boom.