H05VV-F 300/500V PVC Insulated and sheathed Flexible Cable
Introduction
H05VV-F cable is designed for use in domestic appliances with a voltage rating of 300/500V, kitchens and offices. It is suitable for use with ordinary duty portable appliances such as radios,washing machines, refrigerators , table lamps and office equipment, etc. where the potential for mechanical stresses and mechanical damage is low.
|
H05VV-F Flexible cable 2 core | H05VV-F Flexible cable 3 core | H05VV-F Flexible cable 4 core |
| | |
CHARACTERISTICS of 318-Y / H05VV-F
CABLE CONSTRUCTION | |
Conductor material | Stranded Class 5 copper to IEC 60228 |
Type of conductor | Circular, stranded |
Insulation | polyvinyl chloride (PVC) |
Electrical characteristics | |
Rated voltage Uo/U (Um) | 300/500V |
Test voltage: | 2000 V |
Usage characteristics | |
Temperature range: | -5 to +70°C |
Maximum operating temperature: | 70°C |
Short-circuit max conductor temperature: | 160°C |
Mechanical Characteristics | |
Cable flexibility | Flexible |
Mechanical resistance to impacts : | Low |
Installation conditions | |
Installation temperature: | 5°C |
Minimum bending radius: | 6 x cable diameter |
Recommended maximum tensile stress: | 50 N/mm² |
| |||
2*0.75 mm2 | 2*1.0 mm2 | 2*1.5 mm2 | 2*2.5 mm2 |
PHYSICAL AND ELECTRICAL CHARACTERISTICS OF H05VV-F 3 CORE CABLE
Description & No. of cross x cross section | minimum wall-thickness | Outer Ø min. - max. | Weight approx. | Maximum current rating Air 25 ℃ | Conductor DC resistant at 20°C | Standard length |
---|---|---|---|---|---|---|
mm² | mm | mm | kg / km | A | Ω/km | m/coil |
H05VV-F 3×0.75 | 0.6 | 6.0-7.6 | 65 | 9.5 | 26 | 100 m/coil |
H05VV-F 3×1.0 | 0.6 | 6.3-8.0 | 75 | 16 | 19.5 | 100 m/coil |
H05VV-F 3×1.5 | 0.7 | 7.4-9.4 | 110 | 20 | 13.3 | 100 m/coil |
H05VV-F 3×2.5 | 0.8 | 9.2-11.4 | 144 | 21 | 7.98 | 100 m/coil |
| |||
3*0.75 mm2 | 3*1.0 mm2 | 3*1.5 mm2 | 3*2.5 mm2 |
PHYSICAL AND ELECTRICAL CHARACTERISTICS OF H05VV-F 4 CORE CABLE
Description & No. of cross x cross section | minimum wall-thickness | Outer Ø min. - max. | Weight approx. | Maximum current rating Air 25 ℃ | Conductor DC resistant at 20°C | Standard length |
---|---|---|---|---|---|---|
mm² | mm | mm | kg / km | A | Ω/km | m/coil |
H05VV-F 4×0.75 | 0.6 | 7.4-9.4 | 75 | 13 | 26 | 100 m/coil |
H05VV-F 4×1.0 | 0.6 | 7.1-9.0 | 95 | 16 | 19.5 | 100 m/coil |
H05VV-F 4×1.5 | 0.7 | 8.4-10.5 | 130 | 20 | 13.3 | 100 m/coil |
H05VV-F 4×2.5 | 0.8 | 10.1-12.5 | 200 | 27 | 7.98 | 100 m/coil |
| |||
4*0.75 mm2 | 4*1.0 mm2 | 4*1.5 mm2 | 4*2.5 mm2 |
PHYSICAL AND ELECTRICAL CHARACTERISTICS OF H05VV-F 5 CORE CABLE
Description & No. of cross x cross section | minimum wall-thickness | Outer Ø min. - max. | Weight approx. | Maximum current rating Air 25 ℃ | Conductor DC resistant at 20°C | Standard length |
---|---|---|---|---|---|---|
mm² | mm | mm | kg / km | A | Ω/km | m/coil |
H05VV-F 5×0.75 | 0.6 | 7.4-9.3 | 95 | 13 | 26 | 100 m/coil |
H05VV-F 5×1.0 | 0.6 | 7.8-9.8 | 120 | 16 | 19.5 | 100 m/coil |
H05VV-F 5×1.5 | 0.7 | 9.3-11.6 | 170 | 20 | 13.3 | 100 m/coil |
H05VV-F 5×2.5 | 0.8 | 11.2-13.9 | 260 | 27 | 7.98 | 100 m/coil |
* Dimensions and specifications may be changed without prior notice.
Designation | Nominal Voltage U0 / U (V) | According to DIN VDE 0285-525 | According to design to IEC | Links |
---|---|---|---|---|
PVC-wring cables single wire | 300/500 | H05V-U | 60227 IEC 05 | |
PVC-wring cables fine wires | 300/500 | H05V-K | 60227 IEC 06 | |
PVC-insulated cables single wire | 450/750 | H07V-U | 60227 IEC 01 | |
PVC-insulated cables Multi-stranded wires | 450/750 | H07V-R | 60227 IEC 01 | |
PVC-insulated cables fine wires | 450/750 | H07V-K | 60227 IEC 02 | |
Multi-core PVC-Sheathed cables round | 300/300 | H03VV-F | 60227 IEC 52 | |
Multi-core PVC-Sheathed flexible cables round | 300/500 | H05VV-F | 60227 IEC 53 | |
Light PVC sheathed cables for fixed wiring | 300/500 | — | 60227 IEC 10 | |
PVC Insulated Flexible Twin Twisted Electrical Wire | 300/300 | — | 60227 IEC 43 |
Packaging | |
|
Manufacturing process | |
1. copper rod 2. wire drwaing(from 8 mm diameter to different size) 3. Wire annealing 4. Insulation ( PVC compand with different color) 5. Sparking test 6. packing | |
CE | IEC | China Compulsory Certificate, 3C |
| | |
– Certificate No. : CE170103005324 – Certified through China quality certification centre | – Certificate No. : CN39750 – Certified through China quality certification centre | – Certificate No. : 2004010105108087 – Certified through China quality certification centre |
* All substances of the cable meet the requirements of RoHS Directive-compliant
Shenzhen chengtiantai cable operates certified management systems compliant with:
| Certificate | Information |
| ISO 9001:2008 Quality management systems | – Certificat ISO 9001:2008 |
| ISO 14001:2004 Environmental management systems | – Certificat ISO 14001:2004 – Shenzhen chengtiantai cable industry development Co.Ltd. ; – Certified through Guangdong quality Testing CTC Certification Co.Ltd.; – Valid until 13 January 2019 |
| OHSAS 18001:2007 Assessment specification for occupational health & safety management systemsenvironmental management systems | – Certificat OHSAS 18001:2007 |
| |
● Cable production started 1983 ● Sales in 2016 about 500 million USD ● 100,000 m2 Production area ● 8 workshop | ● 200 Sets Of Testing Equipment ● 100 Testing Items ● 12 cabling machines ● 8 armouring machines |