1000kw 1250KVA Container type Industrial cummins silent diesel generator
PRODUCT DESCRIPTION |
Cummins Engine :
Cummins is the world's leading manufacturer of power equipment. It has invested more than US$140
million in China. As the largest foreign investor in China's engine industry, Cummins has eight joint
ventures and wholly-owned manufacturing companies in China, of which Dongfeng Cummins produces
B. C and L series diesel engines, Chongqing Cummins produces M, N and K series diesel engines.
The products comply with ISO 3046, ISO 4001, ISO 8525, IEC 34-1, GB1105, GB/T 2820, CSH 22-2,
VDE 0530 and YD/T 502-2000 "Technical requirements for communication-specific diesel generator sets"
and other standards.
Genset Model | BS-C1250 | ||
Prime Power (kw/kva) | 1000/1250 | Standby Power(kw/kva) | 1100/1375 |
Voltage (v) | 400/230 | Rated Speed (rpm) | 1500 |
Frequency (Hz) | 50 | Rated Current (A) | 1804 |
Connection: | 3 phase 4 wire | Power Factor: | 0.8 |
Engine Model: | KTA50-G3 | Alternator Model: | LVI 634G |
Net Weight (kgs)-Open | 11000 | Net Weight (kgs)-Silent | 13000 |
Dimensions (mm)-Open | 4980X2070X2300 | Dimensions (mm)-Silent | 40’Ft container |
Engine Parameter: | |
Manufacturer/Model Air Intake System Fuel System Cylinder numbers Displacement Bore x Stroke Compression Ratio Max. Power Governing System | CCEC, Cummins, KTA50-G3, 4 stroke PT Fuel Pump, EFC electronic governor 60° Vee,16 cylinders 50.3L 159 x 159 mm 13.9 : 1 1227KW / 1669HP Electronic |
Exhaust System | |
Exhaust gas flow Exhaust temperature Max. Back Pressure(mm Hg) | 3728 L/s 520 ℃ 51 |
Intake System | |
Max. Allowed Pressure with Dirty Filter Element (mm H 2 O) with Clean Filter Element (mm H 2 O) Air Flow |
635 381 1605 L/s |
Fuel System | |
100% Load (Prime) 75% Load(Prime) 50% Load (Prime) | 261L/h 199L/h 139L/h |
Lube System | |
Oil Capacity Total system capacity(L) Oil Pressure at rated speed | 151 L 177 L 345-483 kPa |
Cooling system | |
Coolant Capacity(Engine only) Thermostat Max. Water Temperature | 161 L 82-93℃ 104℃ |
Alternator Parameter: Basic Information | |
The alternators meet the standards of: GB755, BS5000, VDE00530, NEMAMG1-22,IED34-1,CSA22.2 and AS1350 | |
Technical Data: | |
Manufacturer: Phases: Connection: Bearing numbers: Power Factor: Protection Class: Altitude Condition: Excitation: Insulation class/Temp. rise class: Tel. Influence Factor TIF: Tel. Harmonic Factor THF: Steady State Voltage Regulation: Alternator Capacity: Efficiency: Cooling Air Flow: | STAMFORD,LVI 634G 3 3 phase 4 wire, Y type 1 0.8 IP23 ≤1000M Brushless, self-excitation H / H <50 <2% ≤±1% 1250KVA 94.9% 2.69m³/s |
Engine
Heavy duty diesel engine
Four stroke , water cooled
12V and 24V stater and charge alternator
Cooling radiator and fan
Maintenance free battery including ract and cable
Flexible fuel connection hoses and manual oil sump drain valve
Exhaust silencer
Alternator
Brushless , single bearing , flexible disc
Insulation class : H
Protection class : IP23
Self-exciting and Self-regulation
FAQ |
Q : Do you offer OEM service?
A : Yes
Q : What is your payment term?
A : 30% T/T in advance, the rest payment before shipment. Or irrevocable L/C.
Q : What is your lead time?
A : About 30 days after receiving deposit or original L/C.But if your order with some special design,
then the delivery time is longer.
Q . How to choose the power ?
A : Collect all power of your equipments , take the current into your consideration .
Q . What is the difference between Prime power and Standby power ?
A : Prime power is 12hours continous power , one hour 10% over load in every 12 running hours is allowed .
Standby power is the limit value of maximum output for emergency use . Overloading is prohibited